Lavaca Medical Center

CLIA Laboratory Citation Details

3
Total Citations
20
Total Deficiencyies
11
Unique D-Tags
CMS Certification Number 45D0498881
Address 1400 N Texana, Hallettsville, TX, 77964
City Hallettsville
State TX
Zip Code77964
Phone(361) 798-3671

Citation History (3 surveys)

Survey - November 14, 2024

Survey Type: Standard

Survey Event ID: B7BH11

Deficiency Tags: D5213 D5415 D6127 D6127 D5209 D5213 D5415

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of the laboratory's submitted Form CMS 209, review of the laboratory's personnel records, and staff interview, the laboratory failed to have documentation of evaluating the competency of 1 of 2 Technical consultants and 1 of 2 Technical supervisors. The findings included: 1. A review of the laboratory's submitted Form CMS 209 determined the facility identified 2 technical consultants and two technical supervisors. 2. A review of the laboratory's personnel records determined the facility failed to have documentation of assessing the competency of technical consultant number 2 and technical consultant number 2 (as listed on Form CMS 209). 3. Technical consultant number 2 confirmed the findings in an interview conducted on 11/13/2024 at 1124 hours in the conference room. D5213 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(1) The laboratory must verify the accuracy of any analyte or subspecialty without analytes listed in subpart I of this part that is not evaluated or scored by a CMS- approved proficiency testing program. This STANDARD is not met as evidenced by: Based on review of the laboratory's American Proficiency Institute's proficiency testing records from 2024 and staff interview, the laboratory failed to have Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- documentation of evaluating proficiency results for 5 of 5 events where the results were not graded by the proficiency testing agency. The finding included: 1. A review of the laboratory's American Proficiency Institute's proficiency testing records from 2024 (Immunohematology events 1 and 2) and Microbiology (events 1, 2, and 3) identified results which were return 'not graded' by the proficiency testing agency. They were: a) Immunohematology event 1 Crossmatch Type Sample: SER 01 Sample: SER 02 Sample: SER 03 Sample: SER 04 Sample: SER 05 XMatch Reaction Type Sample: SER 01 Sample: SER 02 Sample: SER 03 Sample: SER 04 Sample: SER 05 b) Immunohematology event 2 Crossmatch Type Sample: SER 06 Sample: SER 07 Sample: SER 08 Sample: SER 09 Sample: SER 10 XMatch Reaction Type Sample: SER 06 Sample: SER 07 Sample: SER 08 Sample: SER 09 Sample: SER 10 c) Microbiology event 1 MIC Value Sample: BL 1 Susceptibility Testing Sample: BL 1 d) Microbiology event 2 MIC Value Sample: UR 06 e) Microbiology event 3 MIC Value Sample: UR 11 Susceptibility Testing Sample: UR 11 2. Technical consultant number 2 (as listed on Form CMS 209) confirmed the findings in an interview conducted on 11/13/2024 at 1000 hours in the conference room. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on surveyor observation and staff interview, the laboratory failed to label one of one Coplin glass staining jar on November 12, 2024 with the content's identity. Findings include: 1. Surveyor observation of the laboratory on 11/13/24 at 11:00 a.m. revealed 1 Coplin glass staining jar that the laboratory failed to label with the content's identity. 2. Further review of the Coplin glass staining jar revealed the preparation date of 11/12/24. 3. In an interview on 11/14/24 at 11:20 a.m. in the conference room, the technical supervisor confirmed the above findings. D6127 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on review of the laboratory's personnel records and staff interview, the laboratory failed to have documentation of the technical supervisor performing two competency assessments for immunohematology testing within the first year of employment for 3 of 3 testing personnel. The finding included: 1. A review of the laboratory's personnel records determined competency assessments for immunohematology were performed by someone other than the technical supervisor during the first year of employment for 3 of 3 testing personnel. They were (as listed on Form CMS 209) a) testing personnel number 4 assessments performed: January -- 2 of 3 -- 2022 June 2022 b) testing personnel number 5 assessments performed: September 2022 March 2023 c) testing personnel number 6 assessments performed: November 2022 March 2023 Each assessment was performed by someone who did not meet the qualification as a technical supervisor. 2. Technical supervisor number 2 (as listed on Form CMS 209) confirmed the findings in an interview conducted on 11/13/2024 at 1100 hours in the conference room. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 7, 2022

Survey Type: Standard

Survey Event ID: FVOV11

Deficiency Tags: D5401 D5401

Summary:

Summary Statement of Deficiencies D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on surveyor observation, review of laboratory policies, and confirmed in interview of laboratory personnel, the laboratory failed to follow its own policy for inoculation of blood culture bottles for 4 of 4 negative vials removed from the analyzer on December 7, 2022 (the day of the inspection). The findings included: 1. Surveyor observation on December 7, 2022, the day of the inspection, found 4 negative blood culture bottles removed from the BD Bactec FX blood culture analyzer. There was no indication that the vials had been marked to determine the amount of blood volume dispensed into each vial. Accession Numbers: 36223360026 (Anaerobic Lytic blood culture bottle) 36223360026 (Aerobic Plus blood culture bottle) 36223360027 (Anaerobic Lytic blood culture bottle) 36223360027 (Aerobic Plus blood culture bottle) 2. Review of the laboratory's policy titled, "Blood Culture Collection" approved by the laboratory director on March 24, 2022, stated, "2) Mark sides of bottles to determine volume of blood to be drawn before sticking the patient. Draw 3 to 10 ml of blood in each bottle using a butterfly set or a needle and syringe. An optimum volume of 10 ml is recommended. Do not overfill bottles as overfilling may cause false positive reactions..." 3. The findings were confirmed in interview with the laboratory manager on December 7, 2022 at 15:09 hours in the laboratory. Key: ml - milliliters Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 26, 2019

Survey Type: Standard

Survey Event ID: 5RN311

Deficiency Tags: D1001 D5411 D5413 D5447 D5545 D0000 D1001 D5411 D5413 D5447 D5545

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was performed March 25-26, 2019. The laboratory was found to be IN COMPLIANCE with the CLIA regulations and recertification is recommended. D1001 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(e) Laboratories eligible for a certificate of waiver must-- (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. This STANDARD is not met as evidenced by: Based on surveyor observation, review of manufacturer's instructions, and confirmed in interview of facility personnel, the laboratory failed to follow the manufacturer's instructions for monitoring revised expiration dates for glucometer controls. The findings were: 1. Surveyor observation made on February 26, 2019 in the Day Surgery Department revealed glucometer controls (lot #106201) with an unopened expiration date of March 31, 2020. The controls were located in the instrument's storage case. The controls were open, but there was no revised expiration date. 2. Review of the manufacturer's instructions for the Precision Xceed Pro glucometer (PRT14160, ART14160, Rev. A) on page 24, it stated, "Check that the bottles of control solutions have not been open for more than 90 days." 3. A phone interview with the Day Surgery nurse confirmed the findings. When asked if she documents the revised expiration date and if she was aware that the controls had a revised expiration date once they were opened, she stated, "No." D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on review of manufacturer's instructions, review of patient results, and confirmed in interview of facility personnel, the laboratory failed to follow the manufacturer's instructions to ensure that results provide only a preliminary analytical test result. The findings were: 1. Review of the manufacturer's instructions for use with the Abbott Architect for Amphetamine, Methamphetamine (307301/R11, B3L370), Barbiturates (307036/R07, B3L380), Benzodiazepines (307267R14, B3L390), Cannabinoids (307075/R09, B3L410), Cocaine (307302/R10, B3L400), Methadone (307083/R07, B3L350), Opiates (307047/R09, B3L340), and Phencyclidine (307019/R07, B6L960) under, "Intended Use" they stated, " ...This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used to obtain a confirmed analytical result. Gas Chromatography/Mass Spectrometry (GC/MS) is the preferred confirmatory method." 2. Random review of patient results from February 2019 revealed the following patient's urine drug screen was performed by the laboratory using the Abbott Architect. The patient's results were: U Amph Scrn: Positive * U Barb Scrn: Negative U Benzodia Scrn: Positive * U Cocaine Scrn: Negative U Opiates Scrn: Negative U PCP Scrn: Negative U Methadone Scrn: Negative U THC Scrn: Negative 3. The patient report did not indicate that the results would be sent out for confirmation. 4. The patient report did not state the results were preliminary positive. 5. Interview with the technical consultant on February 25, 2019 at 15:45 hours in the Board Room confirmed the findings. Key: U - urine Amph - amphetamine Barb - barbiturates Benzodia - benzodiazepines PCP - phencyclidine THC - cannabinoids Scrn - screen D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on surveyor observation, review of manufacturer's instructions, and confirmed in interview of facility personnel, the laboratory failed to monitor the room temperature of the General Stores where laboratory supplies were located. The findings were: 1. Surveyor observation made on February 26, 2019 in the General Stores revealed no means to monitor the room temperature. 2. Further observations revealed the following laboratory items were stored in the Purchasing Department: Greiner Vacuette Pink Top Tubes Lot B18033AS Expiration date: 08-27-19 Quantity: 50 tubes BD Universal Transport Medium Lot 180915800 Expiration date: 10-31- 2019 Quantity: 3 boxes 3. Review of the manufacturer's instructions for the Greiner Vacuette tubes located on the package labeling revealed the storage conditions were "4 - 25 degrees Celsius." 4. Review of the manufacturer's instructions for the BD -- 2 of 4 -- Universal Viral Transport Medium located on the package labeling revealed the storage conditions were "2 - 25 degrees Celsius." 5. It is noted that the supplies were not currently in use for patient testing. 6. An interview with the Engineering Representative on February 26, 2019 in the General Stores confirmed the findings. He confirmed that the temperature of the room was not being documented. Key: BD - Becton Dickinson D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of quality control records, review of patient results, and confirmed in interview of facility personnel, the laboratory failed to ensure at least two levels of quality control were acceptable prior to patient testing. The findings were: 1. Review of quality control records from November 2018, December 2018, and January 2019 revealed that on December 21, 2018, there were not two levels of acceptable quantitative quality control for MAS Diabetes. MAS Diabetes Level 2 (Lot 19062) A1C Acceptable Range: 0.48 - 1.28 Laboratory Result: 1.31 (1) Note: (1) indicated a flag, "Greater than 2SD 2. Review of patient reports from December 21, 2018 revealed the following patients were tested when there were not at least two levels of acceptable quality control: FIN 2121760004 FIN 2256940005 FIN 1063320013 FIN 2101090011 FIN 2100660005 FIN 1046690038 FIN 3011990001 3. An interview with the technical consultant on February 25, 2019 at 16:10 hours in the Board Room confirmed the findings. After her review of the records, she agreed there was only one level of acceptable quality control on December 21, 2018 for MAS Diabetes Control. Key: SD - standard deviation D5545 HEMATOLOGY CFR(s): 493.1269(b)(d) (b) For all nonmanual coagulation test systems, the laboratory must include two levels of control material each 8 hours of operation and each time a reagent is changed. (d) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of instrument verification records, review of the laboratory's data for establishing MNPT (mean normal prothrombin time), and confirmed in interview of facility personnel, the laboratory failed to follow the manufacturer's instructions for performance of its MNPT. The findings were: 1. Review of the manufacturer's instructions retrieved from the instrument verification records for the ACL Top stated, "Donors should be equally divided between male/female." 2. Review of the laboratory's MNPT records for the current lot number revealed the laboratory performed testing on 8 males and 15 females. The laboratory failed to follow the manufacturer's instructions for ensuring that donors are equally divided between male -- 3 of 4 -- and female. 3. An interview with the technical consultant on February 26, 2019 at 10: 30 hours in the Board Room confirmed the findings. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access