Lifelink Iii

CLIA Laboratory Citation Details

2
Total Citations
16
Total Deficiencyies
11
Unique D-Tags
CMS Certification Number 24D0724410
Address 4188 Lexington Ave N, Saint Paul, MN, 55126
City Saint Paul
State MN
Zip Code55126
Phone(612) 638-4900

Citation History (2 surveys)

Survey - January 23, 2024

Survey Type: Standard

Survey Event ID: HM5111

Deficiency Tags: D5791 D6004 D6020 D6052 D5400 D5407 D5441 D5445 D5791 D6004 D6020 D6052

Summary:

Summary Statement of Deficiencies D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: . Based on review of laboratory policies and procedures, patient testing and quality control logs, and interview with laboratory personnel, the laboratory failed to meet the applicable analytic systems requirements in 493.1251 through 493.1283. Findings are as follows: 1. The laboratory failed to adequately define quality control (QC) requirements in an Individualized Quality Control Plan (IQCP) in 2022, 2023, and 2024. See D5441 2. The laboratory failed to perform minimum quality control activities required for Chemistry and Hematology testing in 2022, 2023, and 2024. See D5445 . D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: . Based document review and interview with laboratory personnel, the laboratory director failed to approve one of four written procedures in use by the laboratory in Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- 2022, 2023, and 2024. Findings are as follows: 1. The laboratory performed moderate complexity Chemistry and Hematology testing using the BGEM test card on the Siemens epoc blood analysis system as confirmed by the Technical Consultant (TC) during the entrance interview at 10:05 a.m. on 01/23/24 2. Laboratory Director approval of the Universal Patient Care Guideline, which included the standing test authorization, was not found during review on date of survey. 3. In an interview at 2: 00 p.m. on 01/23/24, the TC confirmed the above finding. . D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory failed to adequately define quality control (QC) requirements in the single Individualized Quality Control Plan (IQCP) in use in 2022, 2023, and 2024. Findings are as follows: 1. The laboratory performed moderate complexity Chemistry and Hematology testing using the BGEM test card on the Siemens epoc blood analysis system as confirmed by the Technical Consultant (TC) during the entrance interview at 10:05 a.m. on 01/23/24. 2. The Quality Assurance General Procedure, used as the Quality Control Plan of the IQCP, indicated 2 levels of QC material were tested with every new lot or shipment and monthly. 3. The TC indicated two levels of Metabolite QC materials and two levels of Hematacrit QC materials were tested with every new lot or shipment and monthly. 4. In an email received at 1:29 p.m. on 01/26/24, the TC confirmed the above finding. . D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory failed to perform minimum quality control activities required for Chemistry and -- 2 of 5 -- Hematology testing in 2022, 2023, and 2024 on two of three analyzers reviewed. Findings are as follows: 1. The laboratory performed moderate complexity Chemistry and Hematology testing using the BGEM test card on the Siemens epoc blood analysis system as confirmed by the Technical Consultant (TC) during the entrance interview at 10:05 a.m. on 01/23/24. 2. The Quality Assurance General Procedure, used as the Quality Control Plan of the Individualized Quality Control Plan (IQCP), indicated 2 levels of QC material were tested with every new lot or shipment and monthly. However, the TC indicated two levels of Metabolite QC materials (L1, L3) and two levels of Hematacrit QC materials (HA, HB) were tested with every new lot or shipment and monthly. See D5441 for incomplete IQCP. 3. QC was not performed as required on two of the three analyzers reviewed in the time period of February 2022 through January 23 2024, as indicated in epoc Enterprise Data Manager reports reviewed on date of survey and provided by the TC on 01/24/24 and 01/25/24. See below. Analyzer 09548 QC data 6/14/22 acceptable 07/14/22 incomplete, missing L1 08/16/22 acceptable No QC performed September - December 2022 Patients tested without QC 07/14/22 - 08/15/22 10 09/16/22 - 12/31/22 12 Analyzer 45685, implemented May 2023 QC data No QC performed June 2023 07/06/23 incomplete, missing L1, L3, HB No QC performed August - October 2023 11/25/23 incomplete, missing L3 No QC performed December 2023 - 01/23/24 Patients tested without QC November 2023 7 December 2023 5 January 2024 1 4. In an interview at 3:35 p.m. on 01/23/24, the TC confirmed the above finding. . D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory failed to follow an established quality assurance procedure and failed to correct problems with quality control performance in 2022 and 2023. Findings are as follows: 1. The laboratory performed moderate complexity Chemistry and Hematology testing using the BGEM test card on the Siemens epoc blood analysis system as confirmed by the Technical Consultant (TC) during the entrance interview at 10:05 a.m. on 01/23 /24 . 2. Quality control (QC) reviews by the TC were required monthly as established in the LifeLink Quality Assessment - 2018 procedure provided by the laboratory. 3. TC1 monthly review of QC data failed to capture missing QC performance and correct problems with QC performance in five months in 2022 and two months in 2023 as shown in the epoc Enterprise Data Manager reports reviewed on date of survey and provided by the TC on 01/25/24 and 01/26/24. See D5445. 4. Testing was performed on 22 patients in 2022 and on 12 patients in 2023 without the required QC. 5. In an interview at 3:35 p.m. on 01/23/23, the TC confirmed the above finding. . D6004 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(a)(b) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently -- 3 of 5 -- and for assuring compliance with the applicable regulations. (a) The laboratory director, if qualified, may perform the duties of the technical consultant, clinical consultant, and testing personnel, or delegate these responsibilities to personnel meeting the qualifications of 493.1409, 493.1415, and 493.1421, respectively. (b) If the laboratory director reapportions performance of his or her responsibilities, he or she remains responsible for ensuring that all duties are properly performed. This STANDARD is not met as evidenced by: . Based on review of laboratory policies and procedures, quality control logs, and previous survey data, the Laboratory Director failed to ensure previously cited deficiencies were corrected. Findings are as follows: The following deficiency was cited during the 09/16/16 and 04/11/18 surveys and was also out of compliance on 01 /23/24. D5445 - the laboratory failed to perform minimum quality control activities required for Chemistry and Hematology testing. . D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: . Based on review of laboratory policies and procedures, quality control logs, and interview with laboratory personnel, the Laboratory Director failed to ensure quality control (QC) requirements were followed in 2022, 2023, and 2024. Findings are as follows: QC was not performed as required on two of the three analyzers reviewed in the time period of February 2022 through January 23 2024. Testing was performed on 22 patients in 2022, on 12 patients in 2023, and on 1 patient in 2024 without required QC. See D5445. . D6052 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8)(vi) The procedures for evaluation of the competency of the staff must include, but are not limited to assessment of problem solving skills. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the Technical Consultant (TC) failed to ensure each and every 2022 competency assessments included a problem solving assessment for the single moderate complexity test performed by the laboratory. Findings are as follows: 1. The laboratory performed moderate complexity Chemistry and Hematology testing using the BGEM test card on the Siemens epoc blood analysis system as confirmed by Technical Consultant 1 during the entrance interview at 10:05 a.m. on 01/23/24. 2. 2022 competency -- 4 of 5 -- assessment documents reviewed for 97 of 97 testing personnel (TP) did not include problem solving evaluations for the BGEM test . 3. In an interview at 10:50 a.m. on 01 /23/24, Technical Consultant 2 confirmed the above finding. . -- 5 of 5 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 11, 2018

Survey Type: Standard

Survey Event ID: K1QZ11

Deficiency Tags: D5431 D6053 D2007 D5445

Summary:

Summary Statement of Deficiencies D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory failed to ensure all personnel who routinely performed patient testing were included in testing proficiency testing samples. Findings are as follows: 1. The laboratory performed proficiency testing (PT) for Chemistry and Hematology using the American Proficiency Institute (API) proficiency testing provider. 2. Review of PT records from API indicated the Clinical Service Manager (CSM) and one testing personnel performed all testing of PT samples in the time period reviewed, September 2016 through March 2018. 3. The Laboratory Personnel Report (CLIA) Form CMS- 209 listed a total of twenty four testing personnel for the laboratory. 4. In an interview on 04/11/18 at 2:55 p.m., the CSM confirmed the above finding. D5431 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(2) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document function checks as defined by the manufacturer and with at least the frequency specified by the manufacturer. Function checks must be within the manufacturer's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- failed to ensure functions checks for the Chemistry and Hematology analyzers were completed as required. Findings are as follows: 1. The laboratory performed Chemistry and Hematology testing as confirmed by the Clinical Services Manager (CSM) during the entrance conference on 04/11/18 at 1:00 p.m. The CSM stated the laboratory had 10 epoc Blood Analysis Systems in use and located at satellite bases throughout Minnesota. 2. A requirement for twice annual verification of the thermal control system was established in the Quality Assurance General Procedure located in the electronic procedures file. 3. Laboratory records indicated the thermal control system for 8 of 10 epoc Blood Analysis Systems was not verified twice annually in the timeframe reviewed; January 2016 to March 2018. See below Thermal control verification dates System 2016-1 2016-2 2017-1 2017-2 2018-1 14180 3/16 12/17 15934 12/17 2/18 15937 2/16 4/17 12/17 15939 2/16 3/17 12/17 15941 12/17 15952 2 /16 10/16 12/17 15983 2/16 12/17 18798 3/17 12/17 3/18 4. In an interview on 04/11 /18 at 3:30 p.m., the Technical Consultant confirmed the thermal system verifications had not been performed at least twice annually as required. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the laboratory failed to perform quality control procedures for Chemistry and Hematology testing using the frequency and quantity established by the laboratory. In addition, the laboratory failed to perform quality control as required by the manufacturer. Findings are as follows: The laboratory performed Chemistry and Hematology testing as confirmed by the Clinical Services Manager (CSM) during the entrance conference on 04/11/18 at 1:00 p.m. The CSM stated the laboratory had 10 epoc Blood Analysis Systems located at satellite bases throughout Minnesota. A. Quality Control frequency and quantity 1. External quality control (QC) for the epoc Blood Analysis System was required using 2 levels of control material for new lots or shipments of testing cards and every 30 days as indicated in the laboratory's Individualized Quality Control Plan (IQCP). 2. Review of epoc Blood Analysis System online QC records for 2 of 10 devices in the time period of September 2016 through March 2018 indicated QC was not consistently performed using the frequency established by the laboratory. See below System QC dates Days elapsed 15939 4/21/17, 6/8/17 49 15952 12/21/16, 2/23 /17 65 3. Laboratory records also indicated QC was not consistently performed with the quantity of control materials established by the laboratory. See below System QC dates Missing level 15952 4/29/17 L1 8/26/17 L3 4. In an interview on 04/11/18 at 3: 55 p.m., the Technical Consultant (TC) confirmed QC had not been performed as establishes in the laboratory's IQCP. *This is a repeat citation from 09/16/16 survey* B. Manufacturer's Quality Control requirements 1. The QA section of the manufacturer's epoc System Manual, dated 2010, indicated 2 levels of control material must be tested in duplicate prior to use of new lots and new shipments of testing -- 2 of 3 -- cards. 2. The laboratory's IQCP did not include duplicate testing of QC materials. 3. Review of epoc Blood Analysis System online QC records for 2 of 10 devices in the time period of September 2016 through March 2018 indicated QC was not performed in duplicate by the laboratory. 4. In an interview on 04/11/18 at 3:10 p.m., the TC confirmed QC was not performed in duplicate as required by the manufacturer. D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: . Based on document review and interview with laboratory personnel, the technical consultant failed to ensure competency was assessed at least semiannually during the first year of patient specimen testing for 3 of 18 new testing personnel trained between 11/10/16 and 08/31/17. Findings are as follows: 1. The laboratory performed Chemistry and Hematology testing as confirmed by the Clinical Services Manager (CSM) during the entrance conference on 04/11/18 at 1:00 p.m. 2. Testing Personnel 16, 17 and 21 (TP16, TP17 and TP21) were listed on the Laboratory Personnel Report (CLIA) Form CMS-209 as full time employees performing moderate complexity testing. 3. Laboratory records indicated the testing personnel were trained and initially assessed for testing competency as listed below. TP Initial competency date TP16 05 /17/17 TP17 05/24/17 TP21 08/02/17 4. Semiannual competency assessments for the these testing personnel were not found during review of laboratory records on date of survey, 04/11/18. The laboratory was unable to provide the missing competency assessment documents upon request. 5. In an interview on 04/11/18 at 1:55 p.m., the CSM confirmed the semiannual competency assessments for TP16, TP17 and TP21 had not been completed. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access