Longstreet Clinic Family Medicine Oakwood

CLIA Laboratory Citation Details

3
Total Citations
10
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 11D0894890
Address 4222 Fairbanks Drive, Oakwood, GA, 30566
City Oakwood
State GA
Zip Code30566
Phone770 534-6503
Lab DirectorKELLY DELL

Citation History (3 surveys)

Survey - November 14, 2024

Survey Type: Standard

Survey Event ID: TC3U11

Deficiency Tags: D0000 D5209 D6022

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on November 14, 2024. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on personnel records review and interview with the laboratory manager, the laboratory director failed to ensure that annual competencies were performed on the technical consultant(TC) by the laboratory director in 2023 and 2024. Findings: 1. A review of personnel testing and competency assessment records revealed that TP 3 (CMS-209 form), who is the technical consultant(TC), had no annual competencies completed by the laboratory director in 2023 and 2024. 2. An interview with the laboratory manager, in the review room, at approximately 12:10 PM, on 11/14/2024, confirmed there were no annual competencies completed in 2023 and 2024 for TP # 3 (CMS 209 form ) on day of survey 11/14/2024. D6022 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- director must-- (e)(5) Ensure that the quality control and quality assessment programs are established and maintained to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on documents review and interview with the lab manager, the laboratory director(LD) failed to ensure that ALL Quality Assurance (QA) guidelines were followed to identify and fix problems in the laboratory in 2023 and 2024 as required by Clinical Laboratory Improvement Amendments (CLIA). Findings: 1. Monthly QA document review revealed the Laboratory Director overlooked his responsility to ensure the technical consultant (TC) was competent in executing her responsibilities as a (TC) in 2023 and 2024. 2. An interview, with the laboratory manager, in the break room, on 11/14/2024 , at approximately 1:45 PM, confirmed the Laboratory Director failed to ensure proper oversight of the personnel competency evaluations in 2023 and 2024. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 22, 2022

Survey Type: Standard

Survey Event ID: VV1X11

Deficiency Tags: D0000 D2000 D2016 D2130 D6015

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on November 22, 2022. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: Based on Proficiency Testing (PT) records review and staff interview, the laboratory failed to enroll in a CMS approved PT program to verify accuracy of its Chemistry testing with the Abbott I-Stat 1 analyzer in 2021 and 2022. Findings include: 1. Patient records and Proficiency Testing (PT) records review revealed the absence of (PT) records and the lack of evidence of registration with a CMS approved (PT) Agency for the Abbott I-Stat 1 Chemistry analyzer in 2021 and 2022. 2. An interview with the Technical Consultant (TC) (TP #3 CMS 209) on 11/22/2022 at approximately 12:00 PM in the break room confirmed failure of the laboratory to enroll in a CMS approved (PT) program in 2021 and 2022. D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: The laboratory failed to maintain satisfactory proficiency testing (PT) performance for automated white blood cell (WBC) differential analytes in 2020, 2021 and 2022 resulting in a second unsuccessful occurrence for WBC differential in two years. (Refer to D 2130). D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on Proficiency Test (PT) document review and staff interview, the laboratory failed to have successful performance in two out of three concecutive testing events in 2020, 2021 and 2022. Findings include: 1. Review of American Proficiency Institute (API) (PT) documents revealed the laboratory failed to have successful performance in Hematology - White Blood Cell Differential Counts for following events: ( Lymphocytes 0% Event 3 of 2020 and 60% Event 1 of 2021), (Basophils 0% Event 2 of 2021 and 20% Event 3 of 2021), (Basophils 20% of Event 3, 2021 and 60% of Event 1, 2022). 2. An interview with the laboratory's, Technical Consultant (TP#3 CMS 209) in the review room at approximately 11:30 AM on 11/22/2022 confirmed the PT unsuccessful findings in 2020, 2021 and 2022. D6015 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4) Ensure that the laboratory is enrolled in an HHS approved proficiency testing program for the testing performed. -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on Proficiency Testing(PT) documents review and staff interview, the Lab Director (LD) failed to ensure that the laboratory was enrolled in a CMS approved (PT) program for all compliance testing analytes as required by Clinical Laboratory Improvement Amendments (CLIA). Findings include: 1. (PT) documents review revealed the laboratory director failed ensure the enrollment in a CMS approved (PT) program for compliance testing (using moderate complexity Cartridges) on the Abbott I-Stat 1 Chemistry analyzer as required in 2021 and 2022. 2. An interview with the Technical Consultant (TP#3 CMS209) in the break room on 11/22/2022, at approximately 12:00 PM confirmed the absence of Proficiency Testing (PT) documentation for the aformentioned Chemistry analyzer in 2021 and 2022. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 2, 2021

Survey Type: Standard

Survey Event ID: IQ4211

Deficiency Tags: D0000 D6065

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on February 2, 2021. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D6065 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1423(b)(1)(2)(3)(4)(i) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located or have earned a doctoral, master's, or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution; or (b)(2) Have earned an associate degree in a chemical, physical or biological science or medical laboratory technology from an accredited institution; or (b)(3) Be a high school graduate or equivalent and have successfully completed an official military medical laboratory procedures course of at least 50 weeks duration and have held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); or (b)(4)(i) Have earned a high school diploma or equivalent; and This STANDARD is not met as evidenced by: Based on testing personnel (TP) document review and interview with the Technical Consultant(TC), the laboratory failed to employ qualified TP performing Provider Performed Microscopy (PPM). Findings include: 1. TP document review revealed the lack of educational documentation for TP #3 (CMS 209) who is a medical assistant (MA) to perform (PPM) procedures on urine sediments. 2. An interview with the (TC), TP#5 (CMS209) in the review room on 2/2/2021 at approximately 12:15 p.m. confirmed the lack of education documentation and qualification for TP#3 (CMS 209) to perform PPM procedures. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --