Louisa Family Practice Plc

CLIA Laboratory Citation Details

2
Total Citations
13
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 49D0226281
Address 101 Woolfolk Street, Louisa, VA, 23093
City Louisa
State VA
Zip Code23093
Phone540 967-2202
Lab DirectorALGER III

Citation History (2 surveys)

Survey - July 25, 2023

Survey Type: Standard

Survey Event ID: 0KFE11

Deficiency Tags: D0000 D5429 D5429 D6046 D6046

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Louisa Family Practice on July 25, 2023 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. Specific deficiencies cited are as follows: D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on a review of the manufacturer's instructions for use, hematology analyzer maintenance records, lack of documentation, and an interview, the laboratory failed to document performance of required annual instrument preventative maintenance in calendar year 2022 (record review timeframe from October 2021 until July 25, 2023). The findings include: 1. Review of the Beckman Coulter DxH 520 Instructions for Use revealed manufacturer's instructions to "Yearly-Lubricate the pistons. Yearly or every 18,000 cycles-Replace the rinsing head O-ring." 2. Review of the laboratory's DxH 520 hematology analyzer's maintenance logs from October 2021 to the date of the inspection on July 25, 2023, revealed documentation of instrument installation on October 6, 2021 and the performance of the required annual maintenance outlined above on July 14, 2023. The inspector requested to review documentation of the piston syringe maintenance and replacement of the O-ring in calendar year 2022. The laboratory provided no documentation to review. 3. In an exit interview with the primary testing personnel on July 25, 2023, at approximately 1:00 PM, the above findings were confirmed. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: Based on the review of Laboratory Personnel Report Form (CLIA) (CMS-209 Form), testing personnel (TP) records, lack of documentation, and interview the Technical Consultant (TC) failed to perform and document the semi-annual and annual competency assessment for one (1) of 1 new TP (record review timeframe October 2021 until July 25, 2023). The findings include: 1. Review of the CMS-209 form revealed that TP A was trained and performing patient testing on 12/23/2021. (See attached personnel code sheet.) 2. Review of TP A's personnel records revealed lack of documentation by the TC of the performance and review of the semi-annual and annual competency assessments at the date of survey on July 25, 2023. The surveyor requested to review TP A's semi-annual and annual competency assessments for calendar year 2022. The laboratory provided documentation of an assessment performed in April 2023. The laboratory provided no documentation of calendar year 2022's assessments. 3. In an exit interview with the primary testing personnel on July 25, 2023, at approximately 1:00 PM, the above findings were confirmed. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 21, 2021

Survey Type: Standard

Survey Event ID: J5DD11

Deficiency Tags: D0000 D2122 D5221 D5791 D0000 D2122 D5221 D5791

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Louisa Family Practice on September 21, 2021 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. Specific deficiencies cited are as follows: D2122 HEMATOLOGY CFR(s): 493.851(b) Failure to attain an overall testing event score of at least 80 percent is unsatisfactory performance. This STANDARD is not met as evidenced by: Based on a review of Centers for Medicare and Medicaid Services CASPER 0096D report form (CMS CASPER 96), proficiency testing (PT) records, and an interview, the laboratory failed to attain an overall score of at least eighty (80) percent (%) of acceptable responses for Hematology in one (1) out of three (3) PT testing events in calendar year 2020. Findings include: 1. During pre-survey duties, the inspector noted that the CMS CASPER 96 report included an overall unsatisfactory PT score for the speciality of Hematology. The pre-survey review revealed the laboratory received 50 % score for 2020 Event 2. 2. During the onsite survey on 09/21/21, the inspector reviewed the laboratory's College of American Pathologists (CAP) PT records (2020 Events 1-3, 2021 Events 1-2). The review revealed the following unsatisfactory scores: 2020 Event 2: Hematology overall scored at 50% (module breakdown Hematocrit scored 0%, Hemoglobin scored 0%, and Platelets scored 0%). 3. An exit interview with the lead nurse at approximately 3:30 PM confirmed the above findings. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) records, lack of documentation, and an interview, the laboratory failed to record evaluation of unsatisfactory scores for three (3) of 3 urine sediment examination and fifteen (15) of 15 hematology analyte challenges reported in calendar years 2020 and 2021. Findings include: 1. Review of the laboratory's College of American Pathologists (CAP) Clinical Microscopy (CM) and Full Hematology Auto Differential (FH) PT records (2020 Events 1-3, 2021 Events 1-2) revealed no evidence of evaluation for the following failed analyte challenge samples: 2020 CAP CM-A (Event 1): USP-01 scored unacceptable; 2020 CAP FH - 2 (Event 2): Hematocrit (HCT 06 - HCT 10 scored 0%), Hemoglobin (HGB 06 - HGB 10 scored 0%), and Platelets (PLT 06 - PLT 10 scored 0%); 2021 CAP CM-A (Event 1): USP-01 and USP-03 scored unacceptable. A total of eighteen (18) unsatisfactory challenges with no record of evaluation. The inspector requested to review documentation that the laboratory evaluated the 18 unacceptable challenge results outlined above. Documentation was not available for review. 2. An exit interview with the lead nurse on 09/21/21 at approximately 3:30 PM confirmed the above findings. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on review of policies and procedures, monthly quality control (QC) records, and an interview, the laboratory failed to follow their policy for QC statistics review in order to monitor, assess and correct problems with the hematology analyzer and complete blood count (CBC) QC materials for 4 of 8 months reviewed for calendar year 2021. Findings include: 1. Review of the laboratory's policies and procedures revealed a quality assurance (QA) plan to monitor, assess and correct problems with the Beckman Coulter AcTDiff hematology analyzer that outlined that the laboratory director (LD) was to review quarterly check lists that included Coulter 4C ES Cell QC data collected/reviewed on a monthly basis. 2. Review of the laboratory's monthly CBC QC records for calendar year 2021 (timeframe of January-August 2021) revealed that the laboratory participated with Beckman Coulter Interlaboratory Quality Assurance Program (IQAP). During the review, the inspector noted there was no LD signature of review for the AcTDiff Levey-Jennings (LJ) or IQAP reports for April, May, June, July. The inspector inquired regarding the lack of documentation of LD review for the 4 months outlined above. No Quarterly QA, IQAP or LJ data log report reviewed by the LD was available for the months requested. 3. An exit interview with the lead nurse on 09/21/21 at approximately 3:30 PM confirmed the above findings. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access