Louisiana Organ Procurement Agency

CLIA Laboratory Citation Details

2
Total Citations
20
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 19D2158638
Address 68190 Highway 190 Service Road, Covington, LA, 70433
City Covington
State LA
Zip Code70433
Phone(800) 521-4483

Citation History (2 surveys)

Survey - May 1, 2023

Survey Type: Standard

Survey Event ID: 9N8811

Deficiency Tags: D0000 D5391 D6022 D0000 D5391 D6022

Summary:

Summary Statement of Deficiencies D0000 A Recertification survey was performed on May 1, 2023 at Louisiana Procurement Organ Agency, CLIA ID # 19D2158638. The laboratory was found in compliance with 42 CFR 493 Requirements for Laboratories; however, standard level deficiencies were cited. D5391 PREANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1249(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the preanalytic systems specified at 493.1241 through 493.1242. This STANDARD is not met as evidenced by: Based on observation, review of patient test records, the laboratory's policies and procedure manual, and quality assurance records, as well as interview with laboratory personnel, the laboratory failed to monitor and correct specimen stability for blood gas testing. Findings: 1. On May 1, 2023 at 10:18 a.m. during the lab tour, the surveyor observed the laboratory utilized the Gem 5000 analyzer for blood gas testing. 2. Review of the laboratory's "Monthly Review" document revealed the laboratory failed to have a quality assurance monitor to identify problems with sample stability. 3. Review of the laboratory's policy and procedure manual revealed the optimal sample stability for blood gas testing was fifteen (15) minutes. 4. Review of patient test records revealed one (1) of three (3) patient samples tested greater than fifteen (15) minutes from the time of collection. 5. In interview on May 1, 2023 at 1: 30 p.m., the Technical Consultant said she does not review sample stability of blood gases. D6022 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control and quality assessment programs are established and maintained to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on record review and interview with personnel, the Laboratory Director failed to ensure that a quality assessment (QA) program was maintained to identify failures in the quality of laboratory services provided. Refer to D5391. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 29, 2019

Survey Type: Standard

Survey Event ID: D7S211

Deficiency Tags: D0000 D5401 D5421 D5469 D6013 D6020 D6031 D0000 D5401 D5421 D5469 D6013 D6020 D6031

Summary:

Summary Statement of Deficiencies D0000 A Certification Survey was performed on July 29, 2019 at Louisiana Organ Procurement Agency, CLIA ID # 19D2158638. The laboratory was found in compliance with 42 CFR 493 Requirements for Laboratories; however, standard level deficiencies were cited. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on record review and interview with personnel, the laboratory failed to establish a complete policy and procedure manual. Findings: 1. Review of the laboratory's policy and procedure manual revealed the laboratory did not have written polices and procedures that included: a) Complete Blood Counts (CBC) flagging issues that occur on the Sysmex XN-430 instrument, to include what alternate actions are taken. 2. In interview on July 29, 2019, the Technical Consultant confirmed the laboratory's policies and procedures did not include CBC flags. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on record review and interview with personnel, the laboratory failed to verify complete performance specifications for Hematology testing. Findings: 1. Observation on July 29, 2019 revealed the laboratory utilized a Sysmex XN430 for Complete Blood Counts (CBCs). 2. Review of the installation and validation records revealed the laboratory did not address reference or normal ranges prior to patient testing. Further review revealed the instrument was approved for use on June 25, 2019. 3. Interview with Personnel 2 and 3 on July 29, 2019 at 1:15 pm revealed the laboratory uses the CBC results to monitor for any changes in the patient, not for direct treament. Personnel 2 confirmed the data provided did not specifically address cerification of the reference ranges. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on observation, record review, and interview with personnel, the laboratory failed to establish their own means and ranges for Quality Control (QC) material utilized for Complete Blood Count (CBC) testing. Findings: 1. Observation by surveyors during laboratory tour on July 29, 2019 revealed the laboratory utilizes the Sysmex XN-430 for CBC testing with XN-L CHECK controls. 2. In interview on July 29, 2019 at 2:18 pm, the Technical Consultant stated the laboratory utilizes the manufacturer's QC ranges for CBC controls. 3. Review of the manufacturer's package insert under the "Performance characteristics and limitations" section revealed "The expected ranges listed on the assay sheet represent estimates of inter-laboratory variation for each parameter. These expected ranges should not be used as QC file limits." 4. Review of the laboratory's quality control records revealed the laboratory utilized XN-L CHECK control lot numbers 9074 and 8355. D6013 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(3)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently -- 2 of 3 -- and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(3) Ensure that-- (e)(3)(ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; This STANDARD is not met as evidenced by: Based on record review and interview with personnel, the Laboratory Director failed to ensure that complete verification procedures were performed. Refer to D5421. D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on observation, record review, and interview with personnel, the Laboratory Director failed to ensure that a quality control program was established and maintained to assure quality laboratory services were provided. Refer to D5469. D6031 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(13) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(13) Ensure that an approved procedure manual is available to all personnel responsible for any aspect of the testing process; This STANDARD is not met as evidenced by: Based on record review and interview with laboratory personnel, the Laboratory Director failed to ensure that an approved procedure manual was available to all personnel. Refer to D5401. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access