Manhattan Specialists Cente, Llc

CLIA Laboratory Citation Details

1
Total Citation
4
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 17D2134301
Address 202 Research Drive, Manhattan, KS, 66503
City Manhattan
State KS
Zip Code66503
Phone(785) 539-4644

Citation History (1 survey)

Survey - January 19, 2022

Survey Type: Standard

Survey Event ID: HZBM11

Deficiency Tags: D2009 D5435 D2009 D5435

Summary:

Summary Statement of Deficiencies D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) from the provider American Academy of Family Physicians (AAFP) Proficiency Testing performed 2/2/2020 to 1/19/2022 and interview with testing personnel #3 (TP#3), the laboratory director (LD) failed to attest on two of six events and testing personnel failed to attest on six of six events that proficiency testing samples were handled in the same manner as patient samples. Findings: 1. Review of the attestation pages for PT from AAFP revealed no signature of the LD or designee was present on AAFT-PT 2021-A and AAFP-PT 2021-C. 2. Review of the attestation pages for PT from AAFP revealed that no testing personnel (TP) signatures were present on: a. AAFT-PT 2020-A, AAFT-PT 2020-B, and AAFT- PT 2020-C b. AAFT-PT 2021-A, AAFT-PT 2021-B and AAFP-PT 2021-C. 3. Interview with the TP#3 on 1/19/22 at 11:30 a.m. confirmed, the LD failed to attest on two of six events and TP failed to attest on six of six events that proficiency testing samples were handled in the same manner as patient samples. D5435 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(2) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must: (i) Define a function check protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- reporting. (ii) Perform and document the function checks, including background or baseline checks, specified in paragraph (b)(2)(i) of this section. Function checks must be within the laboratory's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: Based on an absence of thermometer function check records or certificates of accuracy, protocols for thermometer function checks and interview with the TP#3, the laboratory failed to define and perform a function check protocol for one of one thermometers. Findings: 1. No documentation was available for function checks on one of one thermometers at the time of survey. 2. No documentation was available for the certification of accuracy (NIST traceable) on one of one thermometers at the time of survey. 3. Protocols for the function checks of thermometers were not made available at the time of survey. 4. Interview with TP#3 on 1/19/22 at 11:45 a.m. confirmed, the laboratory failed to define and perform a function check protocol for one of one thermometers. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access