Margaret Ravits & Associates

CLIA Laboratory Citation Details

4
Total Citations
12
Total Deficiencyies
10
Unique D-Tags
CMS Certification Number 31D1058391
Address 721 Summit Avenue, Hackensack, NJ, 07601
City Hackensack
State NJ
Zip Code07601
Phone201 487-3691
Lab DirectorVITALY TERUSHKIN

Citation History (4 surveys)

Survey - January 9, 2025

Survey Type: Standard

Survey Event ID: IS0S11

Deficiency Tags: D3011 D5403 D5413 D5417

Summary:

Summary Statement of Deficiencies D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on surveyor observation of the laboratory reagents, refrigerator and interview with the Medical Assistant (MA), the laboratory failed to ensure protection from biohazardous materials from 11/16/24 to 1/9/25. The findings include: 1. Mart-1 reagents used in Histopathology testing were observed to be stored in the refrigerator where food and drinks were also stored. 2. The MA confirmed on 1/9/25 at 12:15 pm that the laboratory did not ensure protection from biohazardous material. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) (b) The procedure manual must include the following when applicable to the test procedure: (b)(1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (b)(2) Microscopic examination, including the detection of inadequately prepared slides. (b)(3) Step-by- step performance of the procedure, including test calculations and interpretation of results. (b)(4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (b)(5) Calibration and calibration verification procedures. (b)(6) The reportable range for test results for the test system as established or verified in 493.1253. (b)(7) Control procedures. (b)(8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 25, 2023

Survey Type: Standard

Survey Event ID: 9OTN11

Deficiency Tags: D6091

Summary:

Summary Statement of Deficiencies D6091 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(iii) The laboratory director must ensure all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 15, 2021

Survey Type: Standard

Survey Event ID: VWYJ11

Deficiency Tags: D5209 D5401

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on the lack of Competency Assessment (CA) records and interview with the Medical Assistant (MA), the laboratory failed to follow written procedures to perform a CA on one of two Testing Personnel for the calendar year 2020. The MA confirmed on 7/15/21 at 10:40 am that the CA procedure was not followed as stated above. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM) and interview with the Medical Assistant (MA), the laboratory failed to follow the PM for "Proficiency Testing" (PT) for "Mohs Micrographic Surgery Skin Specimens" in the calendar year 2020. The findings include: 1. The PM stated "Semi-Annually, the Mohs tech will send two cases for microscopic examination". 2. A review of the PT records revealed one case was sent out 5/56/20 and 6/9/20. 3. The MA confirmed 7/15/21 at 10:10 am that the laboratory did not follow the PM. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 25, 2018

Survey Type: Standard

Survey Event ID: F98C11

Deficiency Tags: D5209 D6107 D5401 D5601 D6103

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on surveyor review of the Competency Assessment (CA) records and interview with the Histotech on phone, the laboratory failed to perform CA accurately on one of one Histotech in 2016 and 2017. The finding include: 1. The CA documentation sheet did not include how CA was accessed, what and when records were reviewed. 2. The Histotech confirmed via phone conversation on 7/25/18 at 11:30 am that CA was not done accurately. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: a) Based on surveyor review of the Procedure Manual (PM), observation of Staining Station (SS) and interview with the Medical Assistant (MA) and phone interview the Histotech, the laboratory failed to have correct procedure for Hematoxylin and Eosin Staining (HES) from 7/6/16 to the dayteof survey. The finding includes: 1. The HES procedure stated two 100% alcohol steps but the SS had three 100% alcohol Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- containers. 2. The MA and Histotech stated on 7/25/18 at 11:15 am that it was an error in HES procedure. b) Based on surveyor review of the PM and interview on phone with the Histotech, the laboratory failed to have a procedure on how to prepare 0.05% Acid Alcohol from 7/6/16 to the date of survey. The Histotech stated during phone conversation on 7/25/18 at 11:15 am that the laboartory did not have a written procedure mentioned above. D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on surveyor review of an accession log, Quality Control (QC) slides and interview with the Medical Assistant (MA), the laboratory failed to document reaction of QC slide on 5/30/17. The finding includes: 1. The laboratory ran and reported eight patient results without evaluating QC on 5/30/17. 2. The MA confirmed on 7/25/18 at 11:30 am that the laboratory did not document QC reaction. b) Based on surveyor review of an accession log, QC slides and interview with the MA, the laboratory failed to stain QC slide on 3/5/17. The MA stated on 7/25/18 at 11:30 am there was no QC slide for 3/5/17. D6103 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(13) The laboratory director must ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM) and interview with the Medical Assistant (MA), the Laboratory Director failed to establish a Competency Assessment (CA) procedure with the applicable elements for Mohs technician from 7 /6/16 to the date of survey. The MA confirmed on 7/25/18 at 10:30 am that a CA procedure was not established. D6107 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(15) The laboratory director must specify, in writing, the responsibilities and duties of each consultant and each supervisor, as well as each person engaged in the performance of the preanalytic, analytic, and postanalytic phases of testing, that identifies which examinations and procedures each individual is authorized to perform, whether -- 2 of 3 -- supervision is required for specimen processing, test performance or result reporting and whether supervisory or director review is required prior to reporting patient test results. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual and interview with the Medical Assistant (MA), the Laboratory Director (LD) failed to specify in writing the list of job responsibilites for LD from 7/6/16 to the date of survey. The MA confirmed on 7 /25/18 at 11:30 am that job resposibilites were not established for LD. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access