Michigan Healthcare Professionals Pc

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 23D0989675
Address 3577 W 13 Mile Road, Suite 310, Royal Oak, MI, 48073
City Royal Oak
State MI
Zip Code48073
Phone248 551-4244
Lab DirectorJEFFREY MARGOLIS

Citation History (2 surveys)

Survey - December 12, 2023

Survey Type: Standard

Survey Event ID: CW5111

Deficiency Tags: D5209 D5445 D5209 D5445

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: . Based on record review and interview with the Technical Consultant (TC), the laboratory failed to establish personnel competency procedures to include a process for new test systems for 2 (Testing Personnel (TP) #1 and #2) of 3 testing personnel listed on Form CMS-209. Findings include: 1. A review of the laboratory's hematology maintenance log sheets revealed the laboratory added a new test system for its hematology complete blood cell count (CBC) in October 2023. 2. A review of the laboratory's "Personnel Competency Policy/Procedure" revealed a lack of a process to follow when the laboratory changes or adds new test methods/systems. 3. A review for 2 of 3 TP competency assessment records revealed a lack of competency assessment performed at a 6-month and a 12-month interval from the initial training checklist (9/21/2022) as follows: a. TP #1 - missing a 6-month assessment which was due 3/2023. b. TP #2 - missing a 12-month assessment which was due 9/2023. 4. An interview on 12/12/2023 at 10:55 am, the TC confirmed competency using the new method was not assessed and documented. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: . Based on record review, lack of documentation, and interview with the Technical Consultant (TC), the laboratory failed to perform control procedures each date of hematology complete blood cell counts patient testing for 1 (11/04/2022) of 8 testing dates reviewed. Findings include: 1. A review of the laboratory's daily control sheets generated from the Beckman Coulter DxH520 series hematology analyzer revealed a lack of documentation for 1 (11/04/2022) of 8 days chosen for review. 2. On 12/12 /2023 at 11:47 am the surveyor requested the documentation for the quality control material for 11/04/2022 and it was not made available. 3. An interview on 12/12/2023 at 11:47 am, the TC confirmed the laboratory had no documentation to show the controls (low, normal, and high) had been performed and documented prior to patient testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 2, 2020

Survey Type: Standard

Survey Event ID: 256S11

Deficiency Tags: D3037 D5439 D3037 D5439

Summary:

Summary Statement of Deficiencies D3037 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(4) Proficiency testing records. Retain all proficiency testing records for at least 2 years. This STANDARD is not met as evidenced by: . Based on record review and interview with the Technical Consultant, the laboratory failed to retain proficiency testing

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access