Mid-Florida Pathology - Mobile Unit 2

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 10D2061921
Address 2100 Prevatt Street, Eustis, FL, 32726
City Eustis
State FL
Zip Code32726
Phone(352) 308-8903

Citation History (2 surveys)

Survey - March 5, 2021

Survey Type: Standard

Survey Event ID: 8ST411

Deficiency Tags: D5609 D0000 D6081

Summary:

Summary Statement of Deficiencies D0000 A Recertification survey was conducted on March 5, 2021. Mid-Florida Pathology - Mobile Unit 2 clinical laboratory was not in compliance with 42 CFR 493, requirements for clinical laboratories. D5609 HISTOPATHOLOGY CFR(s): 493.1273(e)(f) (e) The laboratory must use acceptable terminology of a recognized system of disease nomenclature in reporting results. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to document all the quality control information for the Hematoxylin & Eosin (H&E) stain performed for 5 of 24 months (August 2020, September 2020, October 2020, January 2021, February 2021) from March 5, 2019 to March 5, 2021. Findings: Review of the "Frozen Section H/E Stain Quality Control Log" showed the forms did not contain the lot numbers and the expirations of all the reagents used for August 2020, September 2020, October 2020, January 2021, and February 2021. Review of the "Frozen Section H/E Stain Quality Control Log" showed the form for February 2021 was not filled out. Comparison of the two logs showed dates patients were tested where the H/E log was not filled out, and dates no patients were tested where the H/E log was filled out. The "Frozen Section Log" showed patient testing was done on the following dates: August 10, 20, 24, 27, 2020 September 14, 15, 16, 17, 18, 21, 23, 2020 October 2, 7, 8, 12, 16, 19, 20, 22, 27, 2020 January 4, 6, 11, 13, 21, 25, 26, 27, 2021 February 8, 15, 18, 23, 25, 26, 2021 The "Frozen Section H/E Stain Quality Control Log" showed the reagents were checked, filtered or changed on the following dates: August 7, 10, 20, 24, 25, 26, 27, 28, 2020 September 7, 8, 9, 10, 21, 22, 23, 24, 25, 2020 October 5, 6, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- 7, 8, 9, 12, 16, 19, 20, 22, 23, 27, 30, 2020 January 1, 4, 6, 8, 11, 13, 15, 18, 21, 22, 26, 2021 During an interview on 03/05/2021 at 11:35 AM, the Quality Assurance Coordinator stated the H/E log was not filled out completely. D6081 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(d) Each individual may direct no more than five laboratories. This STANDARD is not met as evidenced by: Based on record review and interview, the Laboratory Director was the director of six (#1, #2, #3, #4, #5, #6) laboratories. Findings: Review of Center for Medicare and Medicare Services Aspen website, showed the Laboratory Director as being the director for six laboratories. Review of the Clinical Laboratory Improvement Amendments (CLIA) Application for Certification signed and dated by the Laboratory Director on 03/03/2021 for laboratory #4, listed the Laboratory Director as being the director for laboratories #2, #3, #5, and #6. During an interview on 03/05/2021 at 12: 37 PM, Laboratory Director stated he was unaware that he was listed as the laboratory directory for laboratory #1, and that he would contact the accreditation agency to get the laboratory director changed to the acting director. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 1, 2019

Survey Type: Standard

Survey Event ID: QG0O11

Deficiency Tags: D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to record the temperature of the laboratory's cryostat from 2/15/19 to 2/26/19. Findings: Review of the laboratory's "Frozen Section Log Sheet" showed that temperature of the cryostat was missing on days that patients testing was performed. The cryostat temperature was not recorded on 2/15/19, 2/18/19, 2/19/19, 2/20/19, 2/21/19 and 2/26/19. On 3/01/19 at 12: 30 PM, Quality Assurance Coordinator stated the cryostat temperature was not recorded on those days. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access