Millard Henry Clinic Of Dardanelle

CLIA Laboratory Citation Details

2
Total Citations
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 04D2263770
Address 1714 State Hwy 22 W, Dardanelle, AR, 72834
City Dardanelle
State AR
Zip Code72834
Phone479 477-3084
Lab DirectorBREANNA HARRIS

Citation History (2 surveys)

Survey - April 16, 2025

Survey Type: Standard

Survey Event ID: WSF011

Deficiency Tags: D5781

Summary:

Summary Statement of Deficiencies D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 15, 2023

Survey Type: Standard

Survey Event ID: 99XH11

Deficiency Tags: D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Through observations made during a tour of the laboratory, review of manufacturer's instruction manual, review of the laboratory's temperature and humidity records and interviews with staff, it was determined the laboratory humidity was below the manufacturer's requirement for the laboratory's Sysmex XP-300. Survey findings include: A) During a tour of the laboratory on 5/15/23 at 11:10 a.m., Sysmex XP-300 was observed in the main laboratory. B) Review of the manufacturer's instruction manual for Sysmex XP-300 and Dardenelle Lab Temperature Ranges revealed conditions of operating requirement listed as "15C-30C (humidity 30%-85%)". C) Review of the laboratory's room temperature and humidity log for October, November, and December of 2022 revealed ten days humidity below 30%. D) Review of the laboratory's room temperature and humidity log for January, February, and March of 2023 revealed six days humidity below 30%. E) In an interview on 5/15/23 at 11:49 a.m. the laboratory staff member (# 2 on the CMS 209 form) confirmed that the Sysmex XP-300 was in use sixteen days below 30% humidity. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access