Min No Aya Win Human Services Center

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 24D0676492
Address 927 Trettel Lane, Cloquet, MN, 55720
City Cloquet
State MN
Zip Code55720
Phone(218) 879-1227

Citation History (2 surveys)

Survey - December 16, 2025

Survey Type: Special

Survey Event ID: QRE511

Deficiency Tags: D0000 D2012 D2000

Summary:

Summary Statement of Deficiencies D0000 The Min No Aya Win Human Services laboratory was found to be out of compliance with the regulations of the Clinical Laboratory Improvement Amendments of 1988 (42 C.F.R. part 493) upon completion of the off-site PT referral investigation performed on 12/16/25. The following condition-level deficiency was cited: 493.801 Enrollment and testing of samples . D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: . Based on review of 2024 and 2025 Wisconsin State Laboratory of Hygiene proficiency testing attestation statements, data submission reports, laboratory testing records, and interview with laboratory personnel, the laboratory engaged in inter- laboratory communication with an affiliated laboratory in 2024. Refer to D2012 . D2012 TESTING OF PROFICIENCY TESTING SAMPLES (b)(4) Laboratories that perform tests on proficiency testing samples must not engage in any inter-laboratory communications pertaining to the results of proficiency testing sample(s) until after the date by which the laboratory must report proficiency testing results to the program for the testing event in which the samples were sent. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Laboratories with multiple testing sites or separate locations must not participate in any communications or discussions across sites/locations concerning proficiency testing sample results until after the date by which the laboratory must report proficiency testing results to the program. This STANDARD is not met as evidenced by: . Based on review of 2024 and 2025 Wisconsin State Laboratory of Hygiene proficiency testing attestation statements, data submission reports, laboratory testing records, and interview with laboratory personnel, the Min No Aya Win Human Services Center laboratory engaged in inter-laboratory communication with an affiliated laboratory regarding one Hematology PT sample and two General Immunology PT samples prior to the PT event submission deadlines in 2024. Findings are as follows: 1. Min No Aya Win Human Services Center (MNAW), performed Complete Blood Counts (CBC's), Amnisure Rupture of Fetal Membranes (ROM), and microscopic examinations for skin fungal elements, vaginal wet preps, and urine sediment as determined during a routine survey completed on 12/11/25. 2. An affiliated laboratory, the Center for American Indian Resources (CAIR) performed Complete Blood Counts (CBC's), Amnisure Rupture of Fetal Membranes (ROM), and microscopic examinations for skin fungal elements, vaginal wet preps, and urine sediment as confirmed by the laboratory director (LD) during a complaint investigation conducted on 12/16/25. 3. One individual held the Laboratory Director (LD), Technical Consultant and Testing Personnel (TP) position at both laboratories. Seven additional TP were employed by the organization; each had a primary location assignment but occasionally worked at the other location if needed. The LD and four TP were assigned to MNAW and three TP were assigned to CAIR. 4. Both CAIR and MNAW performed PT in 2024 and 2025 using the Wisconsin State Laboratory of Hygiene (WSLH) proficiency testing provider. The PT samples were distributed among the TP as much as possible at each location for each event. Entry of PT results at each location was performed by whomever performed each individual test. Each TP was responsible for entering their own results for each event. 5. A 12/16/25 review, performed at the CAIR laboratory, of CAIR and MNAW 2024 and 2025 WSLH PT attestation statements, data submission reports, and laboratory testing records revealed former TP AD performed testing and submitted results for 3 WSLH PT samples at both MNAW and CAIR locations in 2024 as listed below: WSLH event Sample information 2024-HemeReg1 CBC sample AF5-4 2024-Semen2 ROM samples AE-3 and AE-4 Scope of communication 1/30 CBC challenges in 2024 and 2024 2/8 ROM challenges in 2024 and 2025 No other instances of an individual testing the same PT sample at both locations in 2024 and 2025 were found. 6. The Proficiency Testing Policy in use by both laboratories prohibited referral of PT samples to a reference laboratory for additional testing or confirmation of results. Prohibition of inter- laboratory communication was not included in the policy. 7. In an interview at 3:30 p. m. on 12/16/25 at the CAIR laboratory, the LD confirmed the above findings. . -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 3, 2022

Survey Type: Standard

Survey Event ID: 2F4711

Deficiency Tags: D5403 D5403 D5821 D5821

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)