Mitchell Family Medicine, Llc

CLIA Laboratory Citation Details

3
Total Citations
8
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 04D2165967
Address 924 State Hwy 77, Marion, AR, 72364
City Marion
State AR
Zip Code72364
Phone870 739-8670
Lab DirectorAARON MITCHELL

Citation History (3 surveys)

Survey - September 30, 2026

Survey Type: null

Survey Event ID: OD8H11

Deficiency Tags: D0000 D2016 D2130 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficency testing desk review was performed September 30th, 2026 and the laboratory was found not in compliance with the following CONDITION LEVEL DEFICIENCIES: D2016 - 42 Code of Federal Regulations (C.F.R.) 493.803 Condition: Successful participation (proficiency testing) D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director. The following acronyms will be utilized in this report: API-American Proficiency Institute CASPER - Certification and Survey Provider Enhanced Reporting CLIA - Clinical Laboratory Improvement Act CMS - Centers for Medicare and Medicaid Services HHS - Department of Health and Human Services WBC-DIFF - White Blood Cell Differential D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This CONDITION is not met as evidenced by: Based on review of the 2026 CMS CASPER Reports 0155D, and API records (2026-1 and 2026-2), the laboratory failed to achieve satisfactory performance in a proficiency program approved by the HHS for each specialty, subspecialty, and analyte or test in which the laboratory is certified under the CLIA. The laboratory failed to successfully participate in the specialty of hematology for the analyte WBC-DIFF. Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events is unsuccessful performance as cited at D2130. D2130 HEMATOLOGY CFR(s): 493.851(f) (f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the CMS CASPER Reports 0155D and API proficiency testing results, the laboratory failed to achieve satisfactory performance for two of two consecutive testing events (2026-1 and 2026-2) proficiency testing for the analyte WBC-DIFF. Survey Findings follow: A. A review of CASPER 0155D reports revealed the following results for two of two testing events for WBC-DIFF: 2026-1: 0% 2026-2: 0% B. A review of API records confirmed the findings. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of CMS 0155D and API proficiency testing results for 2026, the laboratory director failed to provide overall management and direction of the laboratory services. The laboratory director failed to ensure that the proficiency testing samples are tested as required under Subpart H of this part. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on the 2026 proficiency testing event results, the laboratory director failed to ensure the laboratory successfully participated in proficiency testing for the Hematology test WBC-DIFF . Refer to D2130. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 12, 2026

Survey Type: Standard

Survey Event ID: VWB711

Deficiency Tags: D5469 D5793

Summary:

Summary Statement of Deficiencies D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) (d)(10) Establish or verify the criteria for acceptability of all control materials. (d)(10) (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (d)(10)(ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (d)(10)(iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. This STANDARD is not met as evidenced by: . Based on a review of laboratory policy and interviews with laboratory staff, it was determined the laboratory failed to document criteria for acceptable quality control for Chemistry. Survey findings include: A. Laboratory policy "Quality Control Protocol" states "..If one control level is outside the expected range (app 2SD ( sic approximately 2 Standard deviations)) for only one day but within 3SD the run may be accepted" and "New lots of control material are verified before use. This is accomplished by running at least one day of the old control with the new. The mean value for these runs must fall within the expected range of the manufacturer. The control ranges for the respective analytes are kept for two years." B. The surveyor reviewed chemistry quality control documentation for November 2025, February, 2026, and March 2026. Records documented a lot change for the "CHEM01" Lyphocheck Unassayed Chemistry Control (new lot 93401) occurred 11/11/25. Records documented one of ten runs for the level one CHEM01 control was omitted from the new lot validation, for all analytes. For Lipase, six of eight runs were omitted from the new lot mean calculation. C. Upon request, the lab was unable to provide documentation showing the mathematical criteria that led to the exclusion of certain Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- runs from the mean calculation for the new lot. D. Upon request, the laboratory was not able to provide methods or criteria for control range and mean adjustments outside of new lot introductions. C. In an interview, at 3:03pm on 5/12/26, the Technical Consultant confirmed that the policy did not clearly specify the mathematical thresholds and procedures for adjusting means and standard deviations for chemistry controls. D5793 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(b)(c) (b) The analytic systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 7, 2020

Survey Type: Standard

Survey Event ID: IIPK11

Deficiency Tags: D5421

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: . Through a review of new instrument validation documentation for the Sysmex 300 XN Hematology Analyzer lack of documentation, as well as interviews with staff, it was determined the Laboratory failed to have the director approve verification procedures to ensure they are adequate to determine the accuracy, precision, and other pertinent performance characteristics as evidenced by: A. A review of the verification documentation for Sysmex 300 XN Hematology Analyzer revealed the signature page of the verification procedure was not approved or signed by the laboratory director. B. Upon request, the laboratory could not produce documentation that the laboratory director approved or signed the validation of the Sysmex 300 XN Hematology Analyzer. C. In an interview on 10/07/2020 at 1030, the technical consultant confirmed the validation procedure for the Sysmex 300 XN Hematology analyzer was not approved or signed by the Laboratory Director. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access