Modern Vascular Of St Louis Llc

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 26D2240331
Address 641 N New Ballas Rd, Creve Coeur, MO, 63141
City Creve Coeur
State MO
Zip Code63141
Phone(314) 648-0101

Citation History (2 surveys)

Survey - April 5, 2023

Survey Type: Special

Survey Event ID: 1S9811

Deficiency Tags: D2016 D2097 D2097 D2131 D2131 D2016 D2096 D2096 D2130 D2130

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of chemistry - core proficiency testing (PT) results reported to the CLIA database by the PT provider for 2022/2023 and email from laboratory manager on March 30, 2023, the laboratory failed to successfully participate in PT. Refer to D2096, the laboratory failed to achieve satisfactory performance for the analytes ionized Calcium, Chloride, Creatinine, Glucose, Potassium, Sodium, Total Carbon Dioxide, and Urea Nitrogen (BUN) in two consecutive testing events; D2097 the laboratory failed to attain an overall testing event score of satisfactory performance for two out of three consecutive testing events; D2130 the laboratory failed to achieve satisfactory performance for the hemoglobin and hematocrit in two consecutive PT Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- events; and D2131 the laboratory failed to achieve an overall testing event score of satisfactory performance for the specialty of hematology in two out of three consecutive PT events. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of chemistry - core proficiency testing (PT) results reported to the CLIA database by the PT provider for 2022/2023 and email from the laboratory manager, the laboratory failed to achieve satisfactory performance for the analytes ionized Calcium, Chloride, Creatinine, Glucose, Potassium, Sodium, Total Carbon Dioxide, and Urea Nitrogen (BUN) in two consecutive testing events. Findings: 1. Review of the chemistry- core PT results for the third event of 2022 showed the laboratory obtained an unsatisfactory score of zero percent for the analytes ionized Calcium, Chloride, Creatinine, Glucose, Potassium, Sodium, Total Carbon Dioxide, and Urea Nitrogen (BUN). 2. Review of the chemistry- core PT results for the first event of 2023 showed the laboratory obtained an unsatisfactory score of zero percent for the analytes ionized Calcium and Glucose. 3. Review of the chemistry- core PT results for the first event of 2023 showed the laboratory obtained an unsatisfactory score of 20 percent for the analytes Creatinine, Sodium, Total Carbon Dioxide, and BUN 4. Review of the chemistry- core PT results for the first event of 2023 showed the laboratory obtained an unsatisfactory score of 40 percent for the analytes Chloride and Potassium. 5. Email from the laboratory manager on March 30, 2023 confirmed the laboratory failed to achieve satisfactory performance two consecutive testing events. D2097 ROUTINE CHEMISTRY CFR(s): 493.841(g) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of chemistry - core proficiency testing (PT) results reported to the CLIA database by the PT provider for 2022/2023 and email from the laboratory manager, the laboratory failed to attain an overall testing event score of satisfactory performance for two out of three consecutive testing events. Findings: 1. Review of chemistry - core PT results for 2022 event three showed the laboratory obtained an overall testing score of zero percent. 2. Review of chemistry - core PT results for 2023 event one showed the laboratory obtained an overall testing score of 20 percent. 3. Email from the laboratory manager on March 30, 2023 confirmed the laboratory failed to attain an overall testing event score of satisfactory performance for two out of three consecutive testing events. D2130 HEMATOLOGY -- 2 of 3 -- CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of hematology results from the chemistry - core proficiency testing (PT) records reported to the CLIA database by the PT provider for 2022/2023 and email from the laboratory manager, the laboratory failed to achieve satisfactory performance for the hemoglobin and hematocrit in two consecutive PT events. Findings: 1. Review of hematology results from the chemistry - core PT results for the third event of 2022 revealed the laboratory obtained an unacceptable score of zero percent for the analytes hemoglobin and hematocrit. 2. Review of hematology results from the chemistry - core PT results for the first event of 2023 revealed the laboratory obtained an unacceptable score of 20 percent for the analyte hemoglobin and hematocrit. 3. Email from the laboratory manager on March 30, 2023 confirmed the laboratory failed to achieve satisfactory performance for the analytes hemoglobin and hematocrit in two consecutive PT events. D2131 HEMATOLOGY CFR(s): 493.851(g) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of hematology results from the chemistry - core proficiency testing (PT) records reported to the CLIA database by the PT provider for 2022/2023 and email from the laboratory manager, the laboratory failed to achieve an overall testing event score of satisfactory performance for the specialty of hematology in two out of three consecutive PT events. Findings: 1. Review of hematology PT results for the third event of 2022 revealed the laboratory obtained an unacceptable score of zero percent for the specialty of hematology. 2. Review of hematology PT results for the first event of 2023 revealed the laboratory obtained an unacceptable score of 20 percent for the specialty of hematology. 3. Email from the laboratory manager on March 30, 2023 confirmed the laboratory failed to achieve satisfactory performance for specialty of hematology in two out of three consecutive PT events. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 30, 2022

Survey Type: Standard

Survey Event ID: 65VZ11

Deficiency Tags: D5421 D5421

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of the performance verification procedures for the Abbott i-stat analyzer and interview with testing personnel (TP) #1, the laboratory failed to demonstrate performance specifications prior to reporting patient test results. Findings: 1. Review of the performance specifications for the Abbott i-stat analyzer showed the laboratory failed to demonstrate accuracy, precision, reportable range and failed to verify that the manufacturer's reference intervals (normal ranges) were appropriate for the laboratory's patient population for the analytes: sodium, potassium, chloride, ionized calcium, glucose, blood urea nitrogen, total CO2, creatinine, hematocrit, and hemoglobin prior to the beginning of patient testing in January 2022. 2. Review of patient results from January 2022 to date March 23, 2022 showed 50 patient results were reported. 3. Interview with TP #1 on March 23, 2022 at 11:00 AM confirmed the laboratory failed to demonstrate performance specifications prior to reporting patient test results. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access