Mohammed Ogaily, Md

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 23D2169553
Address 19727 Allen Rd, Suite 12, Brownstown, MI, 48183
City Brownstown
State MI
Zip Code48183
Phone734 250-6210
Lab DirectorMOHAMMED OGAILY

Citation History (2 surveys)

Survey - August 9, 2022

Survey Type: Standard

Survey Event ID: SNT311

Deficiency Tags: D5403

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 22, 2020

Survey Type: Standard

Survey Event ID: BPXO11

Deficiency Tags: D5429 D5435 D5805 D5429 D5435 D5805

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: . Based on record review and interview with the Technical Consultant (TC), the laboratory failed to perform and document daily shutdown maintenance for the Beckman Coulter DxH 520 hematology analyzer for 27 days of 11 months reviewed. Findings include: 1. A review of the laboratory's "DxH Instrument Maintenance Checklist" revealed the following days when daily shutdown maintenance was not documented: a. 10/10/19 b. 10/11/19 c. 10/14/19 d. 10/15/19 e. 10/21/19 f. 11/4/19 g. 11/6/19 h. 11/12/19 i. 11/15/19 j. 11/26/19 k. 12/13/19 l. 12/19/19 m. 12/23/19 n. 12 /27/19 o. 2/19/20 p. 2/26/20 q. 3/20/20 r. 4/21/20 s. 4/30/20 t. 5/13/20 u. 5/29/20 v. 6 /10/20 w. 6/23/20 x. 7/2/20 y. 7/31/20 z. 8/12/20 aa. 8/18/20 2. A review of the laboratory's established "Performing Shutdown" procedure revealed a section stating, "Beckman Coulter recommends a shutdown once every 24 hours. Shutdown removes diluent and replaces it with cleaner for 30 minutes. It also checks the expiration date and volume of the reagents." 3. A review of the laboratory's quality assurance documentation revealed a lack of documentation of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access