Ne Gastroenterology Associate Pc

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 39D1038526
Address 2812 Scranton-Carbondale Hwy, Blakely, PA, 18447
City Blakely
State PA
Zip Code18447
Phone570 253-3391
Lab DirectorMICHAEL YODER

Citation History (2 surveys)

Survey - April 8, 2025

Survey Type: Standard

Survey Event ID: HO4411

Deficiency Tags: D5805 D5413 D5805 D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of laboratory temperature and humidity records, lack of documentation and interview with Testing Personnel (TP) #3, the laboratory failed to monitor and document temperature and humidity to ensure proper test system operating conditions were met for instrumentation used to perform histopathology testing for 188 of 631 days from 07/17/2023 to 04/08/2025. Findings include: 1. On the day of survey, 04/08/2025, review of the laboratory's temperature and humidity logs revealed the laboratory failed to monitor and document room temperature (laboratory's acceptable range: 20 to 26 degrees Celsius) and humidity (laboratory's acceptable range: 30 to 80%) to ensure proper test system operating conditions were met for 188 of 631 days from 07/17/2023 to 04/08/2025 for the following: - 1 of 1 Tissue-Tek VIP Processor - 1 of 1 Leica EG1160 Embedder - 1 of 1 Leica ST 5020 Stainer - 1 of 1 Leica RM2235 Microtome 2. The hours of laboratory testing are Monday-Friday 08:00 am to 05:00 pm (CMS 116). The laboratory could not provide documentation of temperature and humidity taken on days the laboratory was closed. 3. TP#3 confirmed the above findings on 04/08/2025 at 1:58 pm. D5805 TEST REPORT Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- CFR(s): 493.1291(c) (c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on review of 1 of 1 patient test report and interview with Testing Personnel (TP) #3, the laboratory failed to include the address of the laboratory location where histopathology testing was performed from 07/17/2023 to the day of survey. Findings Include: 1. On the day of survey, 04/08/2025 at 12:50 pm, review of 1 of 1 patient test report revealed the laboratory failed to include the address of the laboratory location where histopathology examinations were performed from 07/17/2023 to 04/08/2025. 2. The laboratory reported an estimated annual volume of 4844 histopathology examinations performed in 2024. (CMS 116) 3. TP #3 confirmed the findings above on 04/08/2025 at 12:50 pm. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 17, 2023

Survey Type: Standard

Survey Event ID: DR3811

Deficiency Tags: D3009 D3009

Summary:

Summary Statement of Deficiencies D3009 FACILITIES CFR(s): 493.1101(c) The laboratory must be in compliance with applicable Federal, State, and local laboratory requirements. This STANDARD is not met as evidenced by: Based on surveyor record review (Application for Exception to Section 5.22(f)) and interview with the laboratory director (LD) and testing personnel #2 (TP), the laboratory failed to ensure that the State of Pennsylvania (PA) regulations were met regarding having a supervisor on site during all normal scheduled working hours in which tests are being performed. Findings include: 1. The PA regulations (5.23 (b)(1)) states: "A general supervisor who meets all the requirements of subsection (a)(1), (2) or (3) and is on the laboratory premises during all normal scheduled working hours in which tests are being performed." 2. Review of the application for Exception to Section 5.22 (f) form signed by the laboratory director (LD) on 09/12/2021 states: " the laboratory director will appoint a qualified general supervisor for each laboratory who will be on-site to oversee laboratory operations during all hours in which testing is being performed and who will review quality control records on a weekly basis". 3. On the day of the survey, 07/17/2023 at 02:05 pm, during an interview, LD and TP #2 stated that the laboratory did not have a qualified supervisor onsite for every hour of patient testing as required by the State of PA. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access