Survey - September 30, 2026

Survey Type: null

Survey Event ID: PPPU11

Deficiency Tags: D0000 D2096 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on September 30, 2026. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following condition deficiencies were cited: D2016 - 42 CFR 493.803 Condition: Successful participation [proficiency testing] D6000 - 42 CFR 493.1403 Condition: Moderate Complex Laboratory Director D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the CASPER 155 report and review of the American Proficiency Institute (API) reports, the laboratory failed to maintain satisfactory proficiency Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- testing (PT) participation for Alkaline Phosphatase ( Alk Phos) in 2026 events 1 & 2 resulting in an initial unsuccessful participation for Alk Phos in the subspecialty of Routine Chemistry. Refer to D 2096 D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) (f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid (CMS) CASPER 155 report and review of American Proficiency Institute (API) reports, the laboratory failed to maintain satisfactory participation in two consecutive proficiency testing events ( 2026 events 1 & 2), resulting in an initial unsuccessful participation for Alk Phos, in the subspecialty of Routine Chemistry. Findings: 1. A review of Casper Report 155 revealed the laboratory failed Alk Phos on the following: 2026 Event 1 Alk Phos Score 0% 2026 Event 2 Alk Phos Score 40% 2. A review of the laboratory's API Reports confirmed the laboratory failed the above scores. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of the CMS CASPER 155 report and review of American Proficiency Institute (API) reports, the laboratory director failed to provide overall management and direction for proficiency testing performance. The laboratory director failed to ensure proficiency testing samples were tested as required in the subspecialty of Routine Chemistry. Refer to D6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on review of the CMS CASPER Report 155 and the API (2026 events 1 & 2) PT evaluation reports, the laboratory director failed to ensure successful proficiency testing performance in Alk Phos, in two consecutive testing events (2026 events 1 &2 ) resulting in the initial unsuccessful participation for Alk Phos. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 23, 2024

Survey Type: Standard

Survey Event ID: XUCF11

Deficiency Tags: D5401 D0000 D5449

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was performed on , July 23, 2024. The facility was found to be NOT in compliance with all applicable CLIA requirements for specialties /subspecialties for 42 CFR. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on Standard Operation Procedure manual (SOP) review and testing personnel (TP) interview, the laboratory failed to ensure an approved procedure was available for the Sulfosalicylic Acid (SSA) used for Total Protein verification. Findings include: 1. SOP review revealed the lack of a procedure to perform SSA. 2. An interview with TP# 2 (CMS 209) in the laboratory on 7/23/24 at 3:25 PM, confirmed the lack of the procedure for SSA. D5449 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(ii)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each qualitative procedure, include a negative and positive control material; (g) The laboratory must document all control procedures performed. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on quality control (QC) document review and TP interview, the laboratory failed to perform and document QC on SSA. Findings include: 1. A review of the laboratory QC documents revealed that there was no QC data available to review on SSA at the time of survey. 2.An interview with TP# 2 (CMS 209) on 7/23/24 at 3:25 PM in the laboratory confirmed controls were not performed on SSA. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 3, 2020

Survey Type: Standard

Survey Event ID: 0RYC11

Deficiency Tags: D5435 D0000

Summary:

Summary Statement of Deficiencies D0000 On September 30, 2020, an off site followup review was completed. The report revealed that