New England Cancer Specialists

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 20D0953704
Address 105 Topsham Fair Mall Rd, Topsham, ME, 04086
City Topsham
State ME
Zip Code04086
Phone207 844-5620
Lab DirectorROBERT CHRISTMAN

Citation History (2 surveys)

Survey - August 24, 2023

Survey Type: Standard

Survey Event ID: 46E511

Deficiency Tags: D5209 D6046 D5429 D6046

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on record review and interview with the Technical Consultant (TC), the laboratory failed to follow the written procedure to assess the competency of all laboratory personnel. Findings include: 1. Review of the laboratory's 2022 employee competency records on 8/24/2023 revealed the Laboratory Director (LD) did not document a competency for the Technical Consultant (TC) for his/her CLIA federal regulatory responsibilities. 2. Review on 8/24/2023 of the laboratory's 'Competency Assessment' Policy revealed: "..competency assessments required of the Technical Supervisor (TS) and Technical Consultant (TC) roles that are done by the Lab Director (LD). If the TS or TC also perform testing in the lab, the technical competency assessment must also be done." 3. Staff interview with the TC on 8/24 /2023 at 12:00pm confirmed the above findings. 4. The laboratory performs 115,469 tests annually in the specialty of Chemistry and 73,310 tests annually in the specialty of Hematology. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on documentation and interview with the Technical Consultant (TC), the laboratory failed to document routine maintenance and function checks on the Vitros 350 Chemistry analyzer. Findings include: 1. Record review of the Vitros 350 weekly maintenance log on 8/24/2023 revealed 8 of 52 weeks undocumented weekly maintenance. 2. Interview with the TC on 8/24/2023 at 12:00pm confirmed the above findings. 3. The laboratory performs 115'469 test annually in the specialty of Chemistry. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: Based on record review and staff interview, the Technical Consultant (TC) failed to evaluate the competency of all testing personnel (TP) to perform moderate complexity testing in the specialties of Hematology and Chemistry. Findings include: 1. Record review on 8/24/2023 of the laboratory's 2022 competency documentation for 2 or 2 TP, revealed the TC had not completed the competencies and peer review to be documented. 2. Record review on 8/24/2023 of the laboratory's competency assessment policy revealed: "The assessments are the responsibility of the technical personnel to complete." 3. Staff interview with the TC on 8/24/2023 at 12:00pm confirmed the above findings. 4. The laboratory performs 73'310 tests annually in the specialty of Hematology and and 115'469 tests annually in the specialty of Chemistry. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 8, 2022

Survey Type: Standard

Survey Event ID: 8FK911

Deficiency Tags: D5209 D5209 D5403 D5407 D5429 D5429 D5403 D5407

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on record review and interview with the laboratory manager (LM), the laboratory failed to follow a written procedure to assess the competency of all laboratory personnel. Findings include: 1. Review of the laboratory's 2020 and 2021 employee competency records on 3/8/2022 revealed that the laboratory did not have competency documentation for the Technical Supervisor (TS) for his/her CLIA federal regulatory responsibilities. 2. Staff interview with the LM on 3/8/2022 at 1:00 PM confirmed the laboratory had not assessed the competency of the TS for the specialties of Chemistry and Hematology. 4. The laboratory performs 159,387 tests annually in the specialties of Chemistry and Hematology. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary