New Jersey Podiatric Physicians

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 31D2142530
Address 4645 Highway 9 North, Howell, NJ, 07731
City Howell
State NJ
Zip Code07731
Phone732 994-5333
Lab DirectorJOSEPH MIGLIOZZI

Citation History (1 survey)

Survey - April 2, 2024

Survey Type: Standard

Survey Event ID: TV8M11

Deficiency Tags: D5217 D5413 D5413

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on surveyor review of Biannual Assessment (BA) records, Procedure Manual (PM) and interview with the Laboratory Consultant (LC) the laboratory failed to follow its "Proficiency Testing" procedure to verify the accuracy and reliability of Histopathology tests from 7/1/22 to 4/2/24. The findings include: 1. The procedure for Proficiency Testing states " if a significant difference of opinion is identified an expert opinion will be obtained for final diagnosis." 2. Case Number NJG22880 was marked as significant disagreement between the reviewing and referring pathologist. 3. There was no documented evidence the expert opinion of a third pathologist was obtained for final diagnosis of the case. 4. The LC confirmed on 4/2/24 at 10:30 am that the laboratory failed to follow its Proficiency Testing procedure. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on surveyor review of the Users Manual (UM) for the Olympus BX40 microscope, the lack of temperature logs and interview with the Laboratory Consultant (LC), the laboratory failed to monitor and document room temperature and humidity where the Professional component (PC) for Histopathology tests were performed from 8/23/22 to the date 4/2/24. The findings include: 1. The UM defined the operating environment ambient temperature as 5 to 40C (41 to 104 F). 2. The UM defined the operating environment of a maximum relative humidity as 80%. 3. There was no record of temperature or humidity in the office where the PC was being performed. 4. The LC confirmed on 4/2/24 at 10:35 am the laboratory failed to monitor and document room temperature and humidity where the PC was being performed. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access