Nih Undiagnosed Diseases Program Clinical Lab

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 21D2093330
Address 50 South Drive Room 5525, Bethesda, MD, 20894
City Bethesda
State MD
Zip Code20894
Phone(301) 496-4000

Citation History (2 surveys)

Survey - November 19, 2020

Survey Type: Standard

Survey Event ID: JD8911

Deficiency Tags: D5415 D6086 D0000 D5219 D5437

Summary:

Summary Statement of Deficiencies D0000 The Centers for Medicare and Medicaid Services (CMS) Philadelphia Regional Office Federal Surveyor conducted an announced routine CLIA recertification survey at NIH Undiagnosed Diseases Program Clinical Laboratory on November 19, 2020. The laboratory was surveyed under 42 CFR part 493 CLIA regulations. Specific deficiencies includes the following: D5219 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(2) At least twice annually, the laboratory must verify the accuracy of any test or procedure listed in subpart I of this part for which compatible proficiency testing samples are not offered by a CMS-approved proficiency testing program. This STANDARD is not met as evidenced by: Based on staff interview and lack of documentation ,the laboratory failed to verify accuracy of testing samples with proficiency testing (PT) of a non-regulated analytes. Findings include: 1.On November 19, 2020 at approximately 12:00 pm, a record review of the laboratory's (PT) records revealed an absence of documentation for (PT) for non-regulated analytes. The surveyor asked, "Does the laboratory perform verification of accuracy of test for the Qubit 3.0 Fluorometer with blind testing or split samples or another methodology". The laboratory director (LD) stated, "Nothing is available for our testing. But I'm sure we can come up with something" 2.During the exit interview with the (TS) and (LD) on November 19, 2020 at 1:00 pm confirmed the above findings. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on the tour of the laboratory and interviews with the technical supervisor (TS) and testing person (TP), the laboratory failed to label reagents currently in use on the Flex Star automated isolation testing system with an open date and expiration date. Findings include: 1.A tour of the laboratory on November 19, 2020 at approximately 10:30 am revealed in-use reagents located on the FlexStar automated isolation testing system: FG3 FlexiGene Hydration Buffer with the no open date and expiration date on the container. 2.During an interview at 10:35 am with (TP), the surveyor asked "Are all in use reagents used for the FlexStar labeled with an open and expiration date?" The (TP) replied, "We could place a label on but we don't, just trust what I'm saying we change it so often." 3.During the exit interview with the (TS) and (LD) on November 19, 2020 at 1:00 pm confirmed the above findings. D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. This STANDARD is not met as evidenced by: Based on the review of Thermo-Scientific NanoDrop performance verification procedures, lack of documentation and interview with testing person (TP) & technical supervisor (TS), the laboratory failed to perform and document calibration verification for the Thermo-Scientific NanoDrop One. Finding include: 1.On November 19, 2020 at approximately 11:00 am during a review of the laboratory's Thermo- Scientific NanoDrop protocols titled - S081 - Instructions NanoDrop One- "Performance Verification Check" revealed the following statements "Recommend Schedule: Every 6 months. Section Performance Check Procedure. Line 16 A Results can be exported &printed at this time or at a later time from the Data Viewer" 2.During an interview at 11:52am with the (TP), the surveyor asked for documentation for the NanoDrop performance verification checks. (TP) stated "We were logging it before, we didn't record and don't have those records." 3.During the exit interview with the (TS) and (LD) on November 19, 2020 at 1:00 pm confirmed the above findings. D6086 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(3)(ii) The laboratory director must ensure that verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of -- 2 of 3 -- the method. This STANDARD is not met as evidenced by: Based on staff interview, review of the Thermo-Scientific NanoDrop One performance verification procedures, lack of documentation, the laboratory director (LD) failed to ensure verification performance procedures were performed for the Thermo-Scientific NanoDrop One according to the manufacture instructions. Findings Include 1. On November 19, 2020 at approximately 11:00 am, during a review of the laboratory's Thermo- Scientific NanoDrop protocols titled - S081 - Instructions NanoDrop One- "Performance Verification Check" revealed the following statements "Recommend Schedule: Every 6 months. Section Performance Check Procedure. Line 16 A Results can be exported &printed at this time or at a later time from the Data Viewer" 2. During an interview at 11:52 am with the (TP), the surveyor asked for documentation for the NanoDrop performance verification checks. (TP) stated "We were logging it before, we didn't record and don't have those records." 3. During the exit interview with the (TS) and (LD) on November 19, 2020 at 1:00 pm confirmed the above findings. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 2, 2018

Survey Type: Standard

Survey Event ID: PEX211

Deficiency Tags: D5391 D5217

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of quality assessment records and interview with the laboratory director, the laboratory failed to put a system in place to verify the accuracy of the sequencing data analysis twice annually. Findings include: 1. Quality assessment records for 2017 did not include verification of accuracy of the sequencing analysis portion of the laboratory's testing. 2. The laboratory director confirmed at approximately 10:35 am on the day of the survey that he was the only person who performed the analysis and interpretation of the sequencing data and that no system was in place to verify the accuracy of that portion of the testing process. D5391 PREANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1249(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the preanalytic systems specified at 493.1241 through 493.1242. This STANDARD is not met as evidenced by: Based on review of standard operating procedures, review of electronic patient testing records and interview with the laboratory director, the laboratory failed to establish a written policy for monitoring the status of samples referred to other laboratories for DNA sequencing. Findings include: 1. The laboratory's Standard Operating Procedure entitled Interpretation, Validation and Returning of Results to Patients dated 09/12/16 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- states that, "The expected turn-around-time currently from the day the sequencing centers received the clinical specimens to when all data is 12 weeks or less." 2. During review of electronic patient testing records 1 of 1 record that was traced from start to finish showed that the sequencing results file had not been received, yet further investigation revealed in fact that the final result had been reported and that the sequencing data had been received. 3. The laboratory director stated at approximately 10:10 am on February 2, 2018 that the laboratory did not have a system in place for monitoring pending sequencing results. The laboratory director confirmed that the standard operating procedure did not address a mechanism for keeping track of samples that had been sent for sequencing but for which data had not been received. -- 2 of 2 --