North Shore Hematology-Oncology Associates Pc

CLIA Laboratory Citation Details

1
Total Citation
8
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 33D0714172
Address 2500 Nesconset Highway, Bldg 26 B, Stony Brook, NY, 11790
City Stony Brook
State NY
Zip Code11790
Phone(631) 751-3000

Citation History (1 survey)

Survey - August 15, 2018

Survey Type: Standard

Survey Event ID: RQ6L11

Deficiency Tags: D5437 D5805 D5805 D6021 D6021 D5437 D6000 D6000

Summary:

Summary Statement of Deficiencies D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. This STANDARD is not met as evidenced by: Based on a surveyor review of hematology calibration records and an interview with the laboratory supervisor and the practice administrator, calibration of the hematology analyzer was not performed at the frequencies required by the manufacturer of the POCH 100i hematology analyzer in calendar year 2018. FINDINGS: 1. The laboratory has two hematology analyzers, Sysmex XS1000i and POCH 100i. The manufacturer of the hematology analyzers and the laboratory's calibration policy require analyzers calibration every six months. 2. The only documentation for the POCH 100i analyzer calibration available for review was for calibration performed in August 2017 during the validation study. The POCH 100i hematology analyzer was therefore out of calibration from February 2018 through the survey date. 3. Approximately 200 patient specimens were tested and reported for hematology during the above time frame when the POCH 100i analyzer was out of calibration. PLEASE NOTE: THIS IS A REPEATED CITATION FROM THE SURVEY CONDUCTED ON JANUARY 27, 2017. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on a surveyor review of randomly selected test reports and an interview with the laboratory supervisor and the practice administrator, the laboratory failed to document complete test results for Prothrombin Time and International Normalized Ratio (PT/INR) in the patients electronic medical records. Findings: It was confirmed by the laboratory supervisor and the practice administrator, on August 15, 2018 at approximately 1:30 PM, that the laboratory failed to follow the laboratory's test report policy which requires documenting the PT and INR test results in the electronic medical records. The laboratory only documented the INR results and failed to document PT test results for approximately 44 patients from January 2017 through April 2017. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on surveyor findings and interview with the laboratory supervisor and the practice administrator, the laboratory director failed to provide overall management of the laboratory. The laboratory director failed to ensure that the laboratory: 1. Maintained the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access