Northeast Georgia Diagnostic Assoc And Clinic, Llc

CLIA Laboratory Citation Details

4
Total Citations
25
Total Deficiencyies
18
Unique D-Tags
CMS Certification Number 11D2137875
Address 1270 Friendship Road, #100, Braselton, GA, 30517
City Braselton
State GA
Zip Code30517
Phone(470) 228-7900

Citation History (4 surveys)

Survey - July 17, 2024

Survey Type: Special

Survey Event ID: KQ6Y11

Deficiency Tags: D0000 D2016 D2108 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on July 17, 2024. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following condition deficiencies were cited: D2016 - 42 CFR 493.803 Condition: Successful participation [proficiency testing] D6000 - 42 CFR 493.1403 Condition: Moderate Complex Laboratory Director D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the CASPER 155 report and review of the American Proficiency Institute (API) reports, the laboratory failed to maintain satisfactory proficiency Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- testing (PT) participation for Thyroid Stimulating Hormone (TSH) in 2024 events 1 & 2, resulting in an initial unsuccessful participation for TSH. Refer to D 2108 D2108 ENDOCRINOLOGY CFR(s): 493.843(g) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid (CMS) CASPER 155 report and review of American Proficiency Institute (API) reports, the laboratory failed to maintain satisfactory participation in two consecutive testing events ( 1st event of 2024 and 2nd event of 2024), resulting in an initial unsuccessful participation for TSH. Findings: 1. A review of Casper Report 155 revealed the laboratory failed TSH on the following: 2024 Event 1 TSH Score 20% 2024 Event 2 TSH Score 20% 2. A review of the laboratory's API Reports confirmed the laboratory failed TSH with the aforementioned scores. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of the CMS CASPER 155 report and review of American Proficiency Institute (API) reports, the laboratory director failed to provide overall management and direction for proficiency testing performance. The laboratory director failed to ensure proficiency testing samples were tested as required. Refer to D6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on review of the CMS CASPER Report 155 and the American Proficiency Institute (API) 2024 events 1 and 2 PT evaluation reports, the laboratory director failed to ensure successful proficiency testing performance in TSH in two consecutive testing events resulting in the initial unsuccessful participation for TSH. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 13, 2022

Survey Type: Special

Survey Event ID: 8R2F11

Deficiency Tags: D0000 D2016 D2075 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on September 13, 2022. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two consecutive events ( 1st and 2nd events of 2022), resulting in the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- first unsuccessful occurrence for General immunoology # 065 including: RA/RF # 225. Findings include: Refer to D 2075 D2075 GENERAL IMMUNOLOGY CFR(s): 493.837(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two consecutive testing events (1st and 2nd events of 2022), resulting in the first unsuccessful performance for RA/RF, analyte # 225. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte # 225 RA/RF on event 1 of 2022 with a score of 60%, and event 2 with a score of 40%. 2. Desk review of the laboratory's proficiency testing reports from American Association of Bioanalysts (AAB) confirmed the laboratory failed RA/RF on Events 1 & 2 of 2022 resulting in the first unsuccessful performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two consecutive events (1st & 2nd events of 2022), resulting in the first unsuccessful occurrence for Rheumatoid Factor (RF), analyte # 225. Findings include: Refer to D 6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory -- 2 of 3 -- maintained satisfactory performance in two consecutive events (1st & 2nd event of 2022), resulting in the first unsuccessful occurrence for RA/RF, analyte # 225. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte # 225 , RF/RA on event 1 of 2022 with a score of 60%, and event 2 of 2022 with a score of 0%. 2. Desk review of the laboratory's proficiency testing reports from American Association of Bioanalysts (AAB) confirmed the laboratory failed RA/RF on events 1 & 2 of 2022, resulting in the first unsuccessful performance. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 25, 2021

Survey Type: Standard

Survey Event ID: ONT211

Deficiency Tags: D0000 D5293 D5400 D5441 D5449 D6076 D6079 D6108 D6109 D6141 D6142

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on February 25, 2021. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5293 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(b)(c) (b) The general laboratory systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 15, 2018

Survey Type: Standard

Survey Event ID: E0QO11

Deficiency Tags: D0000 D2009 D5441 D6127

Summary:

Summary Statement of Deficiencies D0000 An initial Clinical Laboratory Improvement Amendments (CLIA) survey was completed on October 15, 2018. The laboratory was not in compliance with all applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on proficiency test (PT) document review and staff interview, the laboratory director (LD) failed to attest to the routine integration of the PT samples into the patient workload as required. Findings include: 1. American Association of Bioanalysts PT document review revealed the LD failed to provide attestation statements for 2018 --Event 1-- Non-Chemistry (Hematology) and Urinalysis. 2. An interview with the Technical Supervisor on 10/15/18 in a medical office at approximately 2:00 p.m. confirmed the aforementioned lack of attestation statements. D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on quality control (QC) document review and staff interview, the laboratory failed to monitor over time the accuracy and precision of test performance as required. Findings include: 1. QC document review revealed microscopic urinalysis QC was not performed in 2017 and 2018 thus far. 2. An interview with the Technical Supervisor on 10/15/18 in a medical office at approximately 2:00 p.m. confirmed microscopic urinalysis QC was not performed for 2017 and 2018 thus far. D6127 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on testing personnel (TP) competency document review and staff interview, the technical supervisor (TS) failed to evaluate and document the performance of TP responsible for laboratory testing as required. Findings include: 1. TP competency document review revealed the TS failed to perform a six-month competency for Staff #3 (CMS 209) in 2018. 2. An interview with the TS on 10/15/18 in a medical office at approximately 2:00 p.m. confirmed the aforementioned competency was not performed in 2018. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access