Northeast Georgia Physicians Group

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 11D0997747
Address 4754 Martin Road, Flowery Branch, GA, 30542
City Flowery Branch
State GA
Zip Code30542
Phone770 848-9130
Lab DirectorERIC BOHN

Citation History (2 surveys)

Survey - May 17, 2022

Survey Type: Standard

Survey Event ID: Y8X911

Deficiency Tags: D0000 D5217 D6018

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on May 17, 2022. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on American Proficiency Institute (API) testing records review and interview with the laboratory coordinator, the laboratory failed to have successful performance in two out of three consecutive testing events. Findings include: 1.) American Proficiency Institute (API) documents review revealed the laboratory failed to have successful performance in 2020 (0%) Event#1 and 2020 (0%) Event #2 for Vaginal Wet Preparation (KOH), resulting in an "Unsuccessful Participation" in a non- regulated analyte. 2.) An interview with the laboratory coordinator on 05/17/2022 at approximately 12:35 PM in the review room confirmed the above findings in 2020. D6018 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iii) Ensure that all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 25, 2021

Survey Type: Special

Survey Event ID: IPVQ11

Deficiency Tags: D0000 D2016 D2130 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on January 25, 2021. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: D2016-Platelets Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two consecutive events Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (Event 3 of 2019 and Event 1 of 2020), resulting in the first unsuccessful occurrence for Platelets #0815. The findings include: Refer to D2130 D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two consecutive events (Event 3 of 2019 and Event 1 of 2020), resulting in the first unsuccessful occurrence for Platelets #0815. The findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte Platelets #0815 on Event 3 of 2019 with a score of 60% and Event 1 of 2020 with a score of 0%. 2. The criteria for acceptable performance for the specialty of Hematology is a score of 80%. 3. Desk review of the laboratory's proficiency testing reports from American Proficiency Institute (API) confirmed the laboratory failed Platelets #0815 on Events 3 of 2019 and Event 1 of 2020 resulting in the first unsuccessful performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two out of three consecutive events (Event 3 of 2019 and Event 1 of 2020), resulting in the first unsuccessful occurrence for Platelets #0815 in the specialty of Hematology. The findings include: Refer to D6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: -- 2 of 3 -- Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's American Proficiency Institute (API) proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two out of three consecutive events (Event 3 of 2019 and Event 1 of 2020), resulting in the first unsuccessful occurrence for Platelets #0815 in the specialty of Hematology. The findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte Platelets #0815 on Event 3 of 2019 with a score of 60% and Event 1 of 2020 with a score of 0%. 2. The criteria for acceptable performance for the specialty of Hematology is 80%. 3. Desk review of the laboratory's proficiency testing reports from the American Proficiency Institute (API) confirmed the laboratory failed analyte #0815 Platelets for Event 3 of 2019 and Event 1 of 2020 resulting in the first unsuccessful performance. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access