Novant Health Primary Care Clemmons

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 34D0696801
Address 6301 Stadium Drive, Clemmons, NC, 27012
City Clemmons
State NC
Zip Code27012
Phone(336) 766-6473

Citation History (1 survey)

Survey - February 1, 2023

Survey Type: Standard

Survey Event ID: MQ0I11

Deficiency Tags: D6072 D6072 D6021

Summary:

Summary Statement of Deficiencies D6021 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that quality assessment programs are established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on review of the laboratory's quality assessment plan, review of 2020, 2021, and 2022 quality assessment monitors, and interview with the TC (technical consultant) 2/1/23, the laboratory director failed to ensure the quality assessment program was maintained to assure the quality of the laboratory services offered. Findings: The laboratory's quality assessment plan states "...V. PROCESSES / PROGRAM COMPONENTS Quality Assessment Activities 1. Quality Assessment Activities, also known as monitors, will be completed by the testing personnel throughout each year in moderately and highly complex laboratories. 2. Each activity (monitor) will include instructions for completion and reporting. 3. All laboratory personnel must be familiar with and follow the written quality assessment plan and safety policies. ..." The plan includes quarterly monitors and an annual assessment to be completed each year. Review of 2020, 2021, and 2022 quality assessment monitors revealed: 1. There were no quality assessment monitors documented for the 2020 3rd and 4th quarters. 2. There were no quality assessment monitors documented for the 2021 1st and 2nd quarters. 3. There were no annual assessments documented for 2020, 2021, or 2022. During interview at approximately 12:40 p.m., the TC confirmed the quality assessment monitors had not been completed as specified in the quality assessment plan. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D6072 TESTING PERSONNEL RESPONSIBILITIES CFR(s): 493.1425(b)(3) Each individual performing moderate complexity testing must adhere to the laboratory's quality control policies, document all quality control activities, instrument and procedural calibrations and maintenance performed. This STANDARD is not met as evidenced by: A. Based on review of the laboratory's policies and procedures and review of 2020, 2021, and 2022 HemoCue WBC (white blood cell) quality control records 2/1/23, TP (testing personnel) failed to follow the laboratory's policy for validation of each new lot number of control material used on the HemoCue WBC analyzer. Findings: Review of the "HemoCue WBC Analyzer" procedure revealed on page 3 "... Validation of New Lot of Control material The following actions are taken prior to implementation of a new lot number of quality control material: 1. The new lot number of control material is to be tested in parallel with the existing control material. 2. The new lot number of control material will be tested a minimum of 1 time prior to use. ... 4. The results must be compared to the manufacturer's assay ranges and confirmed that the values are within acceptable limits. Document results on the HemoCue WBC QC Lot Validation Study log. ... 6. The manufacturer's package insert, all instrument correlation documentation from the validation study, and any other information regarding the study, will be secured together (stapled or paper clipped) and maintained for 2 years. ..." Review of 2020, 2021, and 2022 HemoCue WBC quality control records revealed there was no documentation the following lot numbers of control material were validated prior to use: 1. HC06201, HC06202, HC06203, expiration 9/5/20; 2. HC09201, HC09202, HC09203, expiration 12/5/20; 3. HC12201, HC12202, HC12203, expiration 3/5/21; 4. HC03211, HC03212, HC03213, expiration 6/5/21; 5. HC06211, HC06212, HC06213, expiration 9/5/21; 6. HC09211, HC09212, HC09213, expiration 12/5/21; 7. HC12211, HC12212, HC12213 expiration 3/5/22; 8. HC03221, HC03222, HC03223, expiration 6/5/22; 9. HC09221, HC09222, HC09223, expiration 12/5/22. B. Based on review of the laboratory's IQCP (Individualized Quality Control Plan) for ACR (albumin/creatinine ratio) testing and review of 2020, 2021, and 2022 ACR quality control records, TP failed to follow their IQCP to ensure quality control results were documented and were acceptable prior to reporting patient test results, failed to document refrigerator and room temperatures and humidity daily, and failed to ensure recorded values were within acceptable limits. Findings: Review of the laboratory's IQCP for Afinion ACR testing states "... External controls (Alere Afinion ACR Controls, Levels 1 and 2) will be tested with each new lot or shipment of test materials, when training new employees, anytime an unexpected result is obtained, and once weekly, on the first day of patient testing. Results will be within the manufacturer's defined range published in the package insert for the control lot number in use. If QC results are not within acceptable limits,

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access