Deficiency Tags: D6066

Summary:

Summary Statement of Deficiencies D6066 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1423(b)(4)(ii) Have documentation of training appropriate for the testing performed prior to analyzing patient specimens. This STANDARD is not met as evidenced by: Based on review of the laboratory's policy and procedure, educational credentials, documentation of training, and interview, the laboratory failed to ensure training was performed by the facility for testing personnel prior to performing patient testing for total protein using the Reichert refractometer for one of 28 testing personnel (one of one transfer employees). Findings follow. A. Review of the laboratory's policy and procedure titled Training Policies - NexLynk on page 4 under 5.2 Employee Training Folders and 5.2.2. Transferred Employees stated, "5.2.2.3. Employees who have completed Medical Screener - Return Donors training and permanently transfer to another donor Center must complete a Moderate Complexity [competency] with their transferred center's CLIA Director." B. Review of educational credentials and training records showed testing personnel #23, as listed on the CMS Form 209, hired 09/08 /2021, had a high school diploma with no documentation of training for total protein using the refractometer. C. Interview with the Quality Assurance Supervisor on January 19, 2022 at 1115 in the office acknowledged there was no documentation of training for testing personnel #23 because they would have to request the documentation of training from their sister facility. He confirmed they do not perform their own training on transfers, and it is not stated in their policy for them to do so. NOTE: Training was not performed at the facility where testing was conducted for transfer employees. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 20, 2020

Survey Type: Standard

Survey Event ID: AS1N11

Deficiency Tags: D2006 D5441 D6016 D6020 D2006 D5441 D6016 D6020

Summary:

Summary Statement of Deficiencies D2006 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b) The laboratory must examine or test, as applicable, the proficiency testing samples it receives from the proficiency testing program in the same manner as it tests patient specimens. This testing must be conducted in conformance with paragraph (b)(4) of this section. If the laboratory's patient specimen testing procedures would normally require reflex, distributive, or confirmatory testing at another laboratory, the laboratory should test the proficiency testing sample as it would a patient specimen up until the point it would refer a patient specimen to a second laboratory for any form of further testing. This STANDARD is not met as evidenced by: Review of the proficiency testing records,

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access