Oxford Biomedical Technologies Inc

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 10D0914874
Address 3555 Fiscal Court Ste 9, Riviera Beach, FL, 33404
City Riviera Beach
State FL
Zip Code33404
Phone(888) 669-5327

Citation History (2 surveys)

Survey - February 19, 2025

Survey Type: Standard

Survey Event ID: 08CL11

Deficiency Tags: D0000 D5775 D6171 D5413 D6168

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Oxford Biomedical Technologies Inc on February 6 - 19, 2025. The laboratory was not in compliance with 42 CFR Part 493, Requirement for Laboratories. The following Conditions were cited: D6168 - Testing Personnel 493-1487 D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of the manufacturer's temperature requirements, quality control records, and interview, the laboratory failed to record the temperature and humidity of the preparation room from 11/08/2024 to 02/06/2025. Findings: 1. Review of the CyBi - Selma User manual noted the "Permissible ambient temperature was +15 degrees Celsius (C) to +37 degrees C" and the "Permissible relative air humidity was less than or equal to 85% at +30 degrees C." 2. Review of the quality control records showed there were no temperature or humidity logs for the preparation room. 3. On 02 /06/2025 at 1:40 PM, the Laboratory Director stated they did not take the temperature or humidity of the preparation room. D5775 COMPARISON OF TEST RESULTS CFR(s): 493.1281(a)(c) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (a) If a laboratory performs the same test using different methodologies or instruments, or performs the same test at multiple testing sites, the laboratory must have a system that twice a year evaluates and defines the relationship between test results using the different methodologies, instruments, or testing sites. This STANDARD is not met as evidenced by: Based on review of the quality control logs, the procedure manual, and interview, the laboratory failed to perform and document the instrument to instrument comparison of 18 modified Sony Flow Cytometers used for Mediator Release Test (MRT) for food sensitivities at least twice annually from 11/08/2022 to 02/06/2025. Findings: 1. Review of the quality control documentation showed there was no documentation of an instrument to instrument comparison. 2. Review of the procedure manual showed there was no procedure on instrument to instrument comparisons. 3. On 02/06/2025 at 2:15 PM, the Laboratory Director stated they did not do an instrument to instrument comparison and did not have a procedure on it. D6168 TESTING PERSONNEL CFR(s): 493.1487 The laboratory has a sufficient number of individuals who meet the qualification requirements of 493.1489 of this subpart to perform the functions specified in 493. 1495 of this subpart for the volume and complexity of testing performed. This CONDITION is not met as evidenced by: Based on review of personnel records, and interview, the laboratory failed to provide the college degree and foreign equivalency evaluation document for 1 (D) of 4 (A - D) Testing Personnel. (See D6171) D6171 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1489(b) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; or (b)(2)(i) Have earned a doctoral, master's, or bachelor's degree in a chemical, biological, clinical or medical laboratory science, or medical technology from an accredited institution; or (b)(2)(ii) Be qualified under the requirements of 493.1443(b)(3) or 493.1449(c)(4) or (5); or (b)(3)(i) Have earned an associate degree in a laboratory science or medical laboratory technology from an accredited institution or (b)(3)(ii) Have education and training equivalent to that specified in paragraph (b)(2)(i) of this section that includes (b)(3)(ii) (A) At least 60 semester hours, or equivalent, from an accredited institution that, at a minimum, includes either (b)(3)(ii)(A)(1) 24 semester hours of medical laboratory technology courses; or (b)(3)(ii)(A)(2) 24 semester hours of science courses that include (b)(3)(ii)(A)(2)(i) 6 semester hours of chemistry; (b)(3)(ii)(A)(2)(ii) 6 semester hours of biology; and (b)(3)(ii)(A)(2)(iii) 12 semester hours of chemistry, biology, or medical laboratory technology in any combination; and (b)(3)(ii)(B) Have laboratory training that includes: (b)(3)(ii)(B)(1) Completion of a clinical laboratory training program approved or accredited by the ABHES or the CAAHEP (this training may be included in the 60 semester hours listed in paragraph (b)(3)(ii)(A) of this section); or (b)(3)(ii)(B)(2) At least 3 months documented laboratory training in each -- 2 of 3 -- specialty in which the individual performs high complexity testing; or (b)(4) Successful completion of an official U.S. military medical laboratory procedures training course of at least 50 weeks duration and having held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); or (b)(5) Notwithstanding any other provision of this section, an individual is considered qualified as a high complexity testing personnel under this section if they were qualified and serving as a high complexity testing personnel in a CLIA-certified laboratory as of December 28, 2024, and have done so continuously since December 28, 2024. (b)(6) For blood gas analysis (b)(6)(i) Be qualified under paragraph (b)(1), (2), (3), (4), or (5) of this section; or (b)(6)(ii) Have earned a bachelor's degree in respiratory therapy or cardiovascular technology from an accredited institution; or (b) (6)(iii) Have earned an associate degree related to pulmonary function from an accredited institution. (b)(7) For histopathology, meet the qualifications of 493.1449 (b) or (f) to perform tissue examinations. This STANDARD is not met as evidenced by: Based on review of personnel records, and interview, the laboratory failed to provide the college degree and foreign equivalency evaluation document for 1 (D) of 4 (A - D) Testing Personnel. Findings: 1. Review of personnel records for Testing Personnel D revealed he had an Advanced Technical Diploma in Medical Laboratory Technology. 2. Review of the website for the college where Testing Personnel D obtained his diploma read, "Upon completion of the program and meeting eligibility requirements, including the attainment of an aligned industry credential, students may be awarded credits toward an Associate Degree . . . ." 3. On 02/19/2025 at 12:39 PM, the Laboratory Director said it may be challenging Testing Personnel D to obtain his transcripts, and would check if he had foreign equivalency evaluation. No foreign equivalency was received. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 19, 2020

Survey Type: Standard

Survey Event ID: XPSO11

Deficiency Tags: D0000 D6128

Summary:

Summary Statement of Deficiencies D0000 An announced recertification survey was conducted on 8/19/20 at Oxford Biomedical Technologies, a clinical laboratory in Riviera Beach, Florida. The laboratory was not in compliance with 42 Code of Federal Regulations (CFR), Part 493, requirements for clinical laboratories. D6128 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least annually after the first year, unless test methodology or instrumentation changes, in which case, prior to reporting patient test results, the individual's performance must be reevaluated to include the use of the new test methodology or instrumentation. This STANDARD is not met as evidenced by: Based on record review and interview with laboratory personnel, there was no documentation to indicate that the technical supervisor reviewed the performance of the general supervisor annually. The findings included: Review of personnel records on 8/19/20 revealed that there was no documentation of annual competency evaluations for the general supervisor for the past two years. During an interview with the general supervisor on 8/19/20 at 10:45 a.m., he confirmed that he had not had an evaluation over the past two years. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access