Pain Institute Of Southern Arizona (Pisa), Pc

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 03D2147621
Address 4881 E Grant Rd, Ste 201, Tucson, AZ, 85712
City Tucson
State AZ
Zip Code85712
Phone520 990-7004
Lab DirectorKEVIN JOHNSON

Citation History (2 surveys)

Survey - September 17, 2024

Survey Type: Standard

Survey Event ID: 5XMV11

Deficiency Tags: D5805

Summary:

Summary Statement of Deficiencies D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on review of the laboratory's test reports and interview with the laboratory director (LD), the laboratory failed to include the address of the laboratory location where testing was performed on the final test report. Findings include: 1. Seven out of seven test reports reviewed during the survey were missing the address of the laboratory where the testing was performed: Accession: 43142 on 10/15/22 Accession: 41958 on 09/15/22 Accession: 48443 on 03/17/23 Accession: 48485 on 03 /21/23 Accession: 56926 on 11/15/23 Accession: 63162 on 05/13/24 Accession: 62794 on 05/01/24. 2. The LD interviewed on 9/17/24 at 11:00 AM confirmed the laboratory failed to include the address of the laboratory location where testing was performed on the final test report. 3. This laboratory performs 282,066 tests annually under the subspecialty of Toxicology. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 4, 2022

Survey Type: Standard

Survey Event ID: EBN711

Deficiency Tags: D5305 D5433 D5311 D5801

Summary:

Summary Statement of Deficiencies D5305 TEST REQUEST CFR(s): 493.1241(c) The laboratory must ensure the test requisition solicits the following information: (1) The name and address or other suitable identifiers of the authorized person requesting the test and, if appropriate, the individual responsible for using the test results, or the name and address of the laboratory submitting the specimen, including, as applicable, a contact person to enable the reporting of imminently life threatening laboratory results or panic or alert values. (2) The patient's name or unique patient identifier. (3) The sex and age or date of birth of the patient. (4) The test(s) to be performed. (5) The source of the specimen, when appropriate. (6) The date and, if appropriate, time of specimen collection. (7) For Pap smears, the patient's last menstrual period, and indication of whether the patient had a previous abnormal report, treatment, or biopsy. (8) Any additional information relevant and necessary for a specific test to ensure accurate and timely testing and reporting of results, including interpretation, if applicable. This STANDARD is not met as evidenced by: Based on review of patient test requisitions and interview with the facility personnel, the laboratory's test requisition failed to identify the specific tests performed by the laboratory. Findings include: 1. The laboratory performs patient testing in the sub- specialty of Toxicology, with an approximate annual test volume of 429,153. The laboratory began patient testing in July 2019. The laboratory performs a urine drug screen on the ImmTox analyzer and performs a confirmation test, if warranted, on the Agilent LC-MS 6460 analyzer. 2. Each test requisition reviewed during the survey conducted on January 4, 2022 included one of three different test types, New Patient UDT Order, Presumptive Urine Drug Screen or Definitive Order UDT Moderate Risk. 3. The test requisitions presented for review during the survey (A24948, A24873 and A24958) failed to list the specific analytes to be tested, instead only listed one of the test types indicated above. 4. No policy was presented for review during the survey to Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- indicate which analytes were included with each test type listed on the test requisition. 5. The facility personnel confirmed that the specific analytes tested by the laboratory were not indicated on the test requisition for the patient testing referenced above, and no policy was established to identify the specific analytes tested in each test type. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. This STANDARD is not met as evidenced by: Based on review of the laboratory's Policy and Procedure manual and interview with the facility personnel, the laboratory failed to establish policies and procedures related to specimen storage and preservation. Findings include: 1. The laboratory performs urine toxicology testing, with an approximate annual test volume of 429,153. The laboratory began patient testing in July 2019. 2. No policy or procedure was presented for review to indicate acceptable specimen storage and preservation requirements for the urine specimens that are tested in the laboratory, specifically specimens that are refrigerated or frozen. 3. The facility personnel confirmed that the laboratory failed to establish policies and procedures for the storage and preservation of urine specimens as indicated above. D5433 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(1) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must establish a maintenance protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. The laboratory must perform and document the maintenance activities specified in paragraph (b)(1)(i) of this section. This STANDARD is not met as evidenced by: Based on lack of maintenance and function check documentation for the pipettes utilized as peripheral equipment involved in patient testing under the sub-specialty of Toxicology and interview with the laboratory director, the laboratory failed to follow established policies and document pipette calibrations as required. Findings include: 1. The laboratory's established policy titled, '1.10 Equipment Maintenance' states, "An orderly preventative maintenance program is intended to increase system reliability and reduce downtime. Each instrument and piece of equipment (including pipettes, balances, etc.) must have a maintenance schedule and records of repair and maintenance performed, including date of repair, reason for repair, and remedial action taken if any. Maintenance records are kept near each instrument that is used for testing". 2. During the survey conducted on January 4, 2022, the laboratory failed to provide evidence that the pipettes used by the laboratory were routinely calibrated as -- 2 of 3 -- required per laboratory policy. The laboratory began patient testing in July 2019. 3. The laboratory director confirmed that the pipettes were not calibrated as required since patient testing began. D5801 TEST REPORT CFR(s): 493.1291(a) The laboratory must have an adequate manual or electronic system(s) in place to ensure test results and other patient-specific data are accurately and reliably sent from the point of data entry (whether interfaced or entered manually) to final report destination, in a timely manner. This includes the following: (a)(1) Results reported from calculated data. (a)(2) Results and patient-specific data electronically reported to network or interfaced systems. (a)(3) Manually transcribed or electronically transmitted results and patient-specific information reported directly or upon receipt from outside referral laboratories, satellite or point-of-care testing locations. This STANDARD is not met as evidenced by: Based on review of patient test reports and interview with the facility personnel, the laboratory failed to have a system in place to ensure the accuracy of test results that are manually entered and electronically interfaced into the laboratory's information system (LIS). Findings include: 1. The laboratory performs toxicology testing on urine specimens on the ImmTox analyzer and the Agilent LC-MS 6460 analyzer, with an approximate annual test volume of 429,153. The laboratory began patient testing in July 2019. 2. The test results from the ImmTox analyzer are electronically interfaced into the Laboratory Information System (LIS), LabDaq. The test results obtained from the Agilent LC-MS analyzer are manually entered by laboratory personnel into the LIS. 3. No documentation was presented for review during the survey conducted on January 4, 2022 to indicate the laboratory has a system in place to ensure the accuracy of patient test results that are electronically interfaced and manually entered into the LIS. 4. The facility personnel confirmed that the laboratory did not have a system in place to verify the accuracy of the patient test results that are electronically sent from the ImmTox analyzer to the LIS or manually entered into the LIS. -- 3 of 3 --