Palm Harbor Dermatology Pa Dba Dermatolgy

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 10D1097650
Address 5310 Clark Rd Ste 201, Sarasota, FL, 34233
City Sarasota
State FL
Zip Code34233
Phone(941) 925-3627

Citation History (1 survey)

Survey - May 11, 2022

Survey Type: Standard

Survey Event ID: WHSB11

Deficiency Tags: D5481 D0000

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Dermatology of Coastal Sarasota on 05/11/22. The laboratory is not in compliance with 42 CFR Part 493, Requirements for Laboratories. The following is a description of the standard level deficiencies: D5481 CONTROL PROCEDURES CFR(s): 493.1256(f)(g) (f) Results of control materials must meet the laboratory's and, as applicable, the manufacturer's test system criteria for acceptability before reporting patient test results. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on record review and interview with the Laboratory Director, the laboratory failed to ensure quality control (QC) for hematoxylin and eosin (H&E) stains were documented and acceptable before reporting patient results from 12/19/19 - 05/11/22. Findings included: Record review of the Daily QC Worksheets for H&E stains revealed no documentation to indicate if the control slides were acceptable or not acceptable for 22 (09/29/20, 10/08/20, 10/15/20, 10/22/20, 11/05/20, 11/12/20, 11/19 /20, 12/3/20, 12/10/20, 12/17/20, 10/21/21, 01/13/22, 01/20/22, 01/27/22, 02/17/22, 02 /24/22, 03/10/22, 03/17/22, 03/24/22, 04/07/22, 04/21/22, and 05/05/22) out of 105 days from 12/19/19 through 05/11/22. Review of the laboratory procedure titled Quality Control Measure for Modified Hematoxylin & Eosin Routine Stain revealed "A quality control slide will be performed every day that the stain is placed into use. The Mohs [micrographically oriented histographic surgery] surgeon will review the slide in order to evaluate the stain quality." On 05/11/22 at 11:10 AM, the Laboratory Director stated the testing personnel were implying that the H&E QC was acceptable when approving the "Daily QC Worksheet" even though it was not documented. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access