Palmetto Family Medicine Of Chesterfield County

CLIA Laboratory Citation Details

2
Total Citations
14
Total Deficiencyies
10
Unique D-Tags
CMS Certification Number 42D1024832
Address 316 Second St, Cheraw, SC, 29520
City Cheraw
State SC
Zip Code29520
Phone843 921-4581
Lab DirectorTRAVIS NOVINGER

Citation History (2 surveys)

Survey - January 6, 2025

Survey Type: Standard

Survey Event ID: 8A4K11

Deficiency Tags: D5429 D5293 D6064 D5891 D5413 D5891 D6064 D0000 D6052 D5429 D6052

Summary:

Summary Statement of Deficiencies D0000 An onsite CLIA recertification survey was conducted at Palmetto Family Medicine of Chesterfield County facility on January 6, 2025, by the South Carolina Department of Public Health's Bureau of Nursing Homes and Medical Services. The laboratory was found to be out of compliance with 42 CFR Part 493, CLIA requirements for laboratories. D5293 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(b)(c) (b) The general laboratory systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 5, 2021

Survey Type: Special

Survey Event ID: SUEP11

Deficiency Tags: D2121 D2016 D2130

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: During a proficiency testing desk review performed on 03/11/2021, based on review of CASPER report 155D and graded reports from American Proficiency Institute (API), it was determined that the laboratory failed to successfully participate in proficiency testing for the specialty of hematology, the analyte cell ID for two of three consecutive proficiency testing events reviewed (2019, Event 3 and 2020, Event 1). See D2121 and D2130. D2121 HEMATOLOGY CFR(s): 493.851(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: During a proficiency testing desk review performed on 03/11/2021, based on review of the CASPER report 155D and laboratory proficiency testing records (graded report from API), it was determined that the laboratory failed to attain a score of at least 80 percent in proficiency testing for the specialty of hematology, the analyte Cell ID for two of three consecutive proficiency testing events (2019 Event 3 and 2021 Event 1). The findings include: 1. Review of CASPER report 155D revealed the following Cell ID proficiency scores for your laboratory: a. 2019, Event 3: 0% b. 2020, Event 1: 7% 2. The scores were confirmed upon review of the graded API reports. Scores less than 80% for these analytes indicate failure or unsatisfactory performance. A failure of the analytes for two consecutive or two out of three testing events is scored as unsuccessful. A failure of the analyte for three consecutive or three out of four/five events is scored as a repeat unsuccessful. D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: During the desk review performed on 03/11/21, based on review of CASPER report 155D and graded API results, it was determined that the laboratory failed to achieve satisfactory performance for Cell ID in two of three consecutive testing events (2019 Event 3 and 2020 Event 1) resulting in unsuccessful proficiency testing performance. See D2121. -- 2 of 2 --