Pediatric Center - Laburnum

CLIA Laboratory Citation Details

3
Total Citations
22
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 49D0719539
Address 4786 Finlay St, Richmond, VA, 23231
City Richmond
State VA
Zip Code23231
Phone804 226-4100
Lab DirectorELIZABETH YAPLE

Citation History (3 surveys)

Survey - December 8, 2022

Survey Type: Standard

Survey Event ID: 7GRV11

Deficiency Tags: D0000 D6018 D0000 D6018 D6029 D6063 D6065 D6029 D6063 D6065

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA Recertification survey was conducted at the Pediatric Center- Laburnum on 12/08/22 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. Specific deficiencies are as follows: The laboratory was not in compliance with the following 42 CFR part 493 CLIA Regulations: D6063 - 42 C.F. R. 493-1421 Condition: Laboratory Testing Personnel. The laboratory is performing COVID-19 testing and is in compliance with the applicable COVID-19 reporting requirements. D6018 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iii) Ensure that all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 11, 2021

Survey Type: Standard

Survey Event ID: CG5711

Deficiency Tags: D0000 D2127 D0000 D2127

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA Recertification on-site survey was conducted at the Pediatric Center- Laburnum on March 11, 2021 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. The initial contact and entrance interview with laboratory conducted on February 22, 2021 with off-site record review of documentation on March 8, 2021. Specific deficiencies cited are as follows: The laboratory is performing COVID-19 testing and in compliance with the applicable COVID-19 reporting requirements. D2127 HEMATOLOGY CFR(s): 493.851(d) Failure to return proficiency testing results to the proficiency testing program within the time frame specified by the program is unsatisfactory performance and results in a score of 0 for the testing event. This STANDARD is not met as evidenced by: Based on the review of proficiency testing (PT) documents and interview, the laboratory failed to submit one (1) of 6 Hematology PT events within the PT program's established timeframe in the calendar year 2020. PT events reviewed include all three events in 2019 and 2020. Findings include: 1. Review of the CASPER Report 0096D CLIA Application and Survey Summary revealed the lab received a score of 0% for the first Hematology event in 2020. 2. Review of the College of American Pathologists (CAP) PT records revealed documentation by the lab director that the lab staff failed to submit the results of the CAP FH-2A 2020 Hematology with Differential within the timeframe established by CAP. The lab received a score of 0%. 3. An interview with the primary testing personnel on March 11, 2021 at approximately 11:30 AM confirmed the findings. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 1, 2018

Survey Type: Standard

Survey Event ID: YLXW11

Deficiency Tags: D0000 D2007 D5437 D6055 D0000 D2007 D5437 D6055

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Pediatric Center- Laburnum on November 1, 2018 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. Specific deficiencies cited are as follows: D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods This STANDARD is not met as evidenced by: Based on review of proficiency testing (PT) records, the Centers for Medicare and Medicaid Services Laboratory Personnel Report form (CMS 209), and an interview, the laboratory failed to rotate PT among all personnel performing complete blood count (CBC) testing in calendar years 2017 and 2018. Findings include: 1. Review of the laboratory's CMS 209 form revealed five (5) testing personnel (TP) who perform patient CBC testing. (See Personnel Code Sheet.) 2. Review of the laboratory's 2016 (third event), 2017 (first, second, third events) and 2018 (first, second, third events) College of American Pathologists (CAP) hematology PT documentation (a total of 7 events) revealed that testing personnel B signed attestations of performing seven (7) of 7 events reviewed. 3. In an interview with the laboratory's primary testing personnel and clinical coordinator at approximately 2:30 PM , it was confirmed that the laboratory failed to rotate hematology PT among all personnel responsible for performing patient CBC testing in calendar years 2017 and 2018. D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. This STANDARD is not met as evidenced by: Based on review of procedures and policies, hematology calibration records, instrument user manual, and an interview, the laboratory failed to document calibration procedures every six (6) months for complete blood count (CBC) patient testing according to their policy and the hematology manufacturer's recommendation from August 22, 2017 to May 1, 2018. Findings include: 1. Review of the laboratory's procedure manual revealed a maintenance policy that outlined to calibrate CBC testing at a frequency of every six (6) months. 2. Review of the laboratory's hematology instrument calibration documentation from November 2016 to the date of the inspection on 11/1/18, a total of twenty-four (24) months, revealed the following three (3) month lapse in CBC calibration: The inspector noted documentation of calibration procedures on 8/22/17. The laboratory documented the next hematology calibration on 5/1/18. The inspector requested to review additional calibration records during the timeframe of February 2018 through April 2018. No additional calibration documentation was available for review. 3. Review of the Medonic M Series instrument user manual revealed maintenance logs and instructions that stated "calibration requirement is every six months". 4. In an interview with the primary testing personnel and clinical coordinator at approximately 2:30 PM, it was confirmed that the laboratory failed to document calibration procedures every 6 months for CBC testing according to their maintenance policy and Medonic M Series recommendation as outlined above. D6055 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing whenever test methodology or instrumentation changes. The individual's performance must be reevaluated to include the use of the new test methodology or instrumentation prior to reporting patient test results. This STANDARD is not met as evidenced by: Based on review of Centers for Medicare and Medicaid Services Laboratory Personnel Report form (CMS 209), a tour, review of analyzer installation validation records, manufacturer's users guide, laboratory personnel files, and an interview, the technical consultant (TC) failed to document training and competency evaluations for three (3) of five (5) testing personnel after a hematology instrument change occurred in the laboratory on May 17, 2017. Findings include: 1. Review of the CMS 209 form revealed that the laboratory director (LD) also performs the duties of technical consultant (TC) and that there are five (5) testing personnel (TP) performing patient -- 2 of 3 -- hematology testing. (Personnel Code Sheet attached.) 2. During a laboratory tour, at approximately 11:00 AM, the inspector noted the laboratory utilizing a Medonic M Series hematology analyzer for complete blood count (CBC) testing. The clinical coordinator stated: "we replaced our Abbott Cell Dyn 1800 with the Medonic in 2017". 3. Review of the laboratory's instrument validation records revealed a new hematology analyzer installation (M Series Serial Number 28800) performed by a Medonic field service technical specialist on 5/17/17. 4. Review of the Medonic M Series User's Guide revealed manufacturer's instructions that the "M Series Training Checklist is to be completed prior to patient testing for all operators". 5. Review of the laboratory personnel files and installation records revealed that the Medonic field service specialist completed onsite training checklists for TP A and TP B on 5/17/17. The inspector requested to review the training competency checklists and evaluations for TP C, TP D, and TP E. No documentation was available for review. 6. In an interview with the primary testing personnel and clinical coordinator at approximately 2:30 PM, it was confirmed that the TC failed to document the Medonic M Series hematology training competency evaluations for 3 of 5 testing personnel prior to utilizing the new instrumentation for patient testing from May 2017 through the date of the survey on November 1, 2018. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access