Pediatric Healthcare Associates

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 07D0717051
Address 4 Corporate Dr Suite 290, Shelton, CT, 06484
City Shelton
State CT
Zip Code06484
Phone(203) 452-8322

Citation History (2 surveys)

Survey - April 13, 2022

Survey Type: Standard

Survey Event ID: Z5YO11

Deficiency Tags: D5791 D5781

Summary:

Summary Statement of Deficiencies D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 28, 2019

Survey Type: Standard

Survey Event ID: ZSOS11

Deficiency Tags: D5401 D5791

Summary:

Summary Statement of Deficiencies D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: A. Based on surveyor observation, record review and staff interview, laboratory personnel failed to follow the established quality control plan (QCP) in the specialty of microbiology. Findings include: 1. Record review on 10/28/19 of the quality control procedures portion of the laboratory's Uricult procedure manual revealed: a. "Upon arrival, examine 2 Uricult culture-paddles per box for: cracked vials, cracked media, dehydration or discoloration of media, freezing, unequal filling, excessive bubbles, contamination, media separated from paddle, excess moisture. b. "Remove the certificate of analysis (COA) from the package insert for each new lot number and attach to your quality control (QC) records. Record the date product is received, product lot number and PASS/FAIL visual inspection results along with the technician's initials on the QC log." 2. Record review on 10/28/19 of the laboratory's quality QCP portion of the individualized quality control plan (IQCP) revealed: a. "PHA relies on the established QCP provided by Uricult." b. "Due to the risk assessment provided by Uricult, we rely on the manufacturer's quality analysis insert." 3. Record review on 10/28/19 of the laboratory's 'Uricult Quality Control Record Log' revealed: a. Visual Inspection Procedure, "Upon arrival, examine 2 Uricult culture- paddles per box for: cracked vials, cracked media, dehydration or discoloration of media, freezing, unequal filling, excessive bubbles, contamination, media separated from paddle, excess moisture." b. "Record the visual inspection results on the form below." c. The last documented visual inspection was for lot number 1880256 with an expiration date of 9/17/19. d. The last COA attached to the QC log was for lot number Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- 1880256 with an expiration date of 9/17/19. 4. Surveyor observation on 10/28/19 at 10:30 AM revealed the Uricult media currently in use has lot number 1889419 with an expiration date of 2/11/20. This lot number was not entered on the Uricult quality control log and the COA was not attached. 5. Staff interview with the technical consultant on 10/28/19 at 10:35 AM confirmed the laboratory failed to follow the established IQCP by saving the certificate of analysis and documenting the physical characteristics of each lot and shipment of Uricult media. B. Based on record review and staff interview, the laboratory failed to follow the established Quality Assurance (QA) plan for Uricult testing in the Uricult IQCP plan. Findings include: 1. Record review on 10./28/19 of the laboratory's QA portion of the Uricult IQCP revealed: a. "Quarterly audit by clinical nurse manager of manual log results against EHR documentation." b. "Quarterly audit by clinical nurse manager of the following: Daily Room Temperature log, Uricult Quality Control Log/attached Certificate of Analysis, Daily temperature log." 2. Record review on 10/28/19 of the laboratory's 'Quarterly CLIA Audits' log revealed: a. The laboratory did not check Uricult manual log results against the EHR documentation for 4 of 4 quarters in 2018. b. The laboratory did not check Uricult manual log results against the EHR documentation for 3 of 3 quarters from 1/1/19 through 9/30/19. 3. Record review on 10/28/19 of random patient Uricult records checked against the EHR documentation reveled: a. Patient #1, collected on 7 /30/19 - Uricult result was not written on the manual log. b. Patient #2, collected on 8 /29/19 - Uricult result was not written on the manual log. c. Patient #3, collected on 10 /1/19 - Uricult result was not written on the manual log. d. Patient #4, collected on 2/1 /19 - EHR documentation does not match manual log. e. Patient #5, collected on 10/26 /19 - EHR documentation does not match manual log. f. Patient #6, collected on 10/18 /19 - EHR documentation does not match manual log. g. Patient #7, collected on 8/29 /19 - EHR documentation does not match manual log. 4. Record review on 10/28/19 of the laboratory's 2018 and 2019 temperature charts revealed the charts are not signed as reviewed by the clinical nurse manager. 5. Staff interview with the clinical nurse manager on 10/28/19 at 11:00 AM confirmed the findings in B1 through B4 above. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to take

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access