Physicians' Medical Center Lab

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 38D0622888
Address 2435 Ne Cumulus Ave Suite A, Mcminnville, OR, 97128
City Mcminnville
State OR
Zip Code97128
Phone503 434-8235
Lab DirectorKEVIN WHERRY

Citation History (2 surveys)

Survey - September 29, 2026

Survey Type: Standard

Survey Event ID: P61611

Deficiency Tags: D5407 D5791 D5793

Summary:

Summary Statement of Deficiencies D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) (d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on review of the Individual Quality Control Plan (IQCP) for the detection of Syphilis antibodies and interview with the lab manager, the laboratory failed to ensure that all changes or updates to the IQCP were approved, signed and dated by the Laboratory Director (LD). Findings include: 1. Upon review of the IQCP for the detection of Syphilis antibodies, it was noted that the specimen source on the original IQCP risk assessment for specimen source said serum. A black line had been drawn through it and the words "venipuncture whole blood had been written in, without a date or initials of the editor. 2. Upon review of the Quality Assurance Plan (QAP) of the IQCP for detection of Syphilis antibodies, it was noted that the last line of the QAP on page 3, stating "IQCP will be evaluated at least annually for effectiveness and altered if needed" had a black line drawn through it and was initialed, but not dated by the Lab Manager. 3. Interview with the Lab manager at 2:30 pm verified that initials on the current IQCP for Syphilis antibodies were his and that he had also drawn the black line through the specimen source on page 1. 4. The laboratory reports performing 391 Syphilis serologies annually. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on review of laboratory Individual Quality Control Procedures (IQCP's) and interview with the Laboratory Director (LD) and the Lab Manager, the laboratory failed to follow the written Quality Assessment procedure (QAP) for the monitoring and review of the testing system and it's components for the detection of Syphilis antibodies, Chlamydia tracomatis infection and Neisseria gonorrhae infection (CT /NG). Findings include: 1. Upon review of the laboratory procedure manual containing the IQCP's for all three (3) analytes, it was noted that the last review for all three (3) of these was in 2022. 2. The last review for the Syphilis antibody assay IQCP was 04/05/2022. The last review for CT/NG infection IQCP was 06/05/2022. 3. The QAP portion of the IQCP's for both, states that review of the IQCP will occur annually. 4. Interview with the LD and Lab manager at 1:25 pm confirmed that they had not performed an annual review nor monitoring of outcomes for either IQCP's since the April and June 2022 dates. 5. The laboratory reports performing 391 Syphilis antibody screens and 596 CT/NG assays annually. D5793 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(b)(c) (b) The analytic systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 25, 2018

Survey Type: Standard

Survey Event ID: 05D311

Deficiency Tags: D5417 D5417

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on inspection of reagents in the laboratory and discussion with one of the Technical Supervisors (TS), the laboratory was using expired reagents. Findings include: 1. Three (3) out of four (4) of the Gram stain reagents in the Microbiology area were expired as follows: Crystal Violet expired 3/30/2018 Grams Iodine expired 3 /31/2018 Safranin expired 4/6/2018 2. Potassium hydroxide (KOH) used for wet mounts showed an expiration date of 3/17/2016. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --