Pinnacle Healthcare Pllc Dba Mission Kids Clinic

CLIA Laboratory Citation Details

3
Total Citations
13
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 45D0966858
Address 1616 N Conway Ave, Mission, TX, 78572
City Mission
State TX
Zip Code78572
Phone956 580-9966
Lab DirectorSERGIO MD

Citation History (3 surveys)

Survey - May 13, 2026

Survey Type: Standard

Survey Event ID: QXC011

Deficiency Tags: D5813 D6063 D6066 D0000

Summary:

Summary Statement of Deficiencies D0000 The laboratory was found to be out of compliance with 42 CFR Part 493, Requirements for Laboratories following a scheduled recertification survey completed on 05/13/2026. The following conditionn was not met: D6063 - 42 C.F.R. 493.1421 Condition: Laboratories performing moderate complexity testing; testing personnel D5813 TEST REPORT CFR(s): 493.1291(g) (g) The laboratory must immediately alert the individual or entity requesting the test and, if applicable, the individual responsible for using the test results when any test result indicates an imminently life-threatening condition, or panic or alert values. This STANDARD is not met as evidenced by: Based on review of the laboratory's policies, review of patient test records from March 2026, and interview with staff, the laboratory failed to have documentation of the notification of 1 of 1 panic values. The findings included: 1. The laboratory's policy titled "Repeat and Panic Value Policy" under the section titled "Policy" stated: "When a critical value is noted it will be verified by repeating the test and the result will be called or given to the Physician with 15-30 minutes. Document on the patient's report the date, time and provider receiving the panic value." 2. The policy defined the following panic values: White Blood Cell: 2. 0 - 37.00 5.0 - 30.00 3. A review of patient test records from March 2026 identified one patient result with a panic value. It was: a) Sequence number: 3963 WBC: 1.2 Sequence number: 3963 WBC: 1.7 4. The patient results did not have documentation of the panic value, the notification of the physician of the panic value, and the date/time of the notification. 5. The technical consultant confirmed the findings in an interview conducted on 05/13/2026 at 10:00 am in the break room. D6063 LABORATORY TESTING PERSONNEL CFR(s): 493.1421 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- The laboratory must have a sufficient number of individuals who meet the qualification requirements of 493.1423, to perform the functions specified in 493. 1425 for the volume and complexity of tests performed. This CONDITION is not met as evidenced by: Based on review of the laboratory's submitted CMS 209, review of the laboratory's personnel records, and interview with staff, the laboratory failed to have documentation of training on the Medonic M-series hematology analyzer for 2 of 3 testing personnel (refer to D6066). D6066 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1423(b)(4)(ii) (b)(6)(ii) Have documentation of laboratory training appropriate for the testing performed prior to analyzing patient specimens. Such training must ensure that the individual has- (b)(6)(ii)(A) The skills required for proper specimen collection, including patient preparation, if applicable, labeling, handling, preservation or fixation, processing or preparation, transportation, and storage of specimens; (b)(6)(ii) (B) The skills required for implementing all standard laboratory procedures; (b)(6)(ii) (C) The skills required for performing each test method and for proper instrument use; (b)(6)(ii)(D) The skills required for performing preventive maintenance, troubleshooting, and calibration procedures related to each test performed; (b)(6)(ii) (E) A working knowledge of reagent stability and storage; (b)(6)(ii)(F) The skills required to implement the quality control policies and procedures of the laboratory; (b) (6)(ii)(G) An awareness of the factors that influence test results; and (b)(6)(ii)(H) The skills required to assess and verify the validity of patient test results through the evaluation of quality control sample values prior to reporting patient test results. This STANDARD is not met as evidenced by: Based on review of the laboratory's submitted CMS 209, review of the laboratory's personnel records, and interview with staff, the laboratory failed to have documentation of training on the Medonic M-series hematology analyzer for 2 of 3 testing personnel. The findings included: 1. A review of the laboratory's submitted Form CMS 209 determined the laboratory identified 3 personnel who performed moderate complexity testing on the Medonic M-series hematology analyzer. 2. A review of the laboratory's personnel records determined the laboratory failed to have documentation of training on the Medonic M-series analyzer for 2 of 3 personnel. They were: a) Testing personnel number 2 Education: High school diploma Start date: 9/2025 b) Testing personnel number 3 Education: High school diploma Start date: 8 /25 3. The technical consultant confirmed the findings in an interview conducted on 05 /13/2026 at 9:00 am in the break room. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 24, 2022

Survey Type: Standard

Survey Event ID: MY8911

Deficiency Tags: D0000 D2010 D0000 D2010

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representative(s) at the exit conference. The facility representative(s) were given an opportunity to provide evidence of compliance with the noted deficiencies, and no such evidence was provided prior to survey exit. The facility was found in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. Note: The CMS-2567 (Statement of Deficiencies) is an official, legal document. All information must remain unchanged except for entering the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 22, 2018

Survey Type: Standard

Survey Event ID: 2QAI11

Deficiency Tags: D0000 D5401 D5793 D5401 D5793

Summary:

Summary Statement of Deficiencies D0000 Noted deficiencies and plans of correction were discussed with the laboratory representative at the entrance and exit conferences. The facility representative was given an opportunity to provide evidence of compliance with the noted deficiencies, and no such evidence was provided prior to survey exit. The facility was found to be in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. Note: The CMS-2567 (Statement of Deficiencies) is an official, legal document. All information must remain unchanged except for entering the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access