Potomac Podiatry Group Pllc

CLIA Laboratory Citation Details

2
Total Citations
14
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 49D2278413
Address 46440 Benedict Dr, Suite 209, Sterling, VA, 20164
City Sterling
State VA
Zip Code20164
Phone(703) 444-9555

Citation History (2 surveys)

Survey - April 9, 2025

Survey Type: Standard

Survey Event ID: 2FM511

Deficiency Tags: D0000 D5401 D5469 D0000 D5401 D5469 D5793 D6093 D5793 D6093

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Potomac Podiatry Group, PLLC on April 8-9, 2025 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Regulations. The deficiencies cited are as follows: D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) (a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: A. Based on a review of the laboratory's policies and procedures, reagent and quality control (QC) records, interviews and lack of documentation, the laboratory failed to follow their established policy to document new lot number acceptable performance of the Thermo MasterMix and Lighthouse panel plates for the seventeen (17) months from November 2023 until April 2025. The findings include: 1. Review of the laboratory's policies and procedures revealed the following policy and instructions, "Reagent Receiving and QC Testing" and "Lot Verification Log" with the following instructions, "On the Log Verification sheet, enter the required information (Item Name, Vendor, Catalog Number, Lot Number, Expiration Date, Storage Temperature, the number of items received in the Count column, the batch/name that the item was tested in the In-Use Batch column, Pass/Fail status of all controls,

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 31, 2023

Survey Type: Standard

Survey Event ID: SLU211

Deficiency Tags: D0000 D5411 D0000 D5411

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA initial survey was conducted at Potomac Podiatry Group on October 30-31, 2023 by the Virginia Department of Health's Office of Licensure and Certification. The laboratory was surveyed under 42 CFR part 493 CLIA Regulations. The specific deficiency cited is as follows: D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on a laboratory tour, review of the laboratory's temperature and humidity records, instrument environmental/operating requirements, lack of documentation, and interview, the lab failed to monitor and document the room temperatures and relative humidity for seventy-four (74) of one-hundred eighty-four (184) days reviewed from May 1, 2023 to October 31, 2023. The findings include: 1. During a tour of the laboratory on October 30, 2023, at approximately 8:45 AM, the surveyor noted an Applied Biosystems QuantStudio 7 flex real-time instrument and ThermoScientific KingFisher Duo Prime instrument in use for patient testing in the laboratory. 2. Review of the laboratory's policies and procedures revealed a procedure, "GEN 14.1.0 Gen: Good Laboratory Practice" (effective date/signed by the laboratory director on 4 /24/2023), with the statements, "5. Instructions, 5.1 Daily Verification Activities, 5.1.1 Lab Personnel-Verify that the temperature and relative humidity of the lab are within the acceptable range, refer to the Environmental Conditions Control & Monitoring System Level Procedure (SLP)." 3. Review of the laboratory's temperature records from May 1, 2023 until October 31, 2023 revealed a lack of documentation of room temperature and relative humidity recordings for the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- following days from May 1, 2023 until October 31, 2023: 5/1/2023-5/5/2023, 5/8 /2023-5/12/2023, 5/15/2023-5/19/2023, 5/22/2023-5/26/2023, 5/29/2023-6/2/2023, 6/5 /2023-6/9/2023, 6/12/2023-6/16/2023, 6/19/2023-6/23/2023, 6/26/2023-6/30/2023, 7/3 /2023, 7/5/2023-7/7/2023, 7/10/2023-7/14/2023, 7/17/2023-7/21/2023, 7/24/2023-7/28 /2023, 7/31/2023-8/4/2023, 8/7/2023-8/11/2023. Total of 74 days of 184 days reviewed. The surveyor requested to review documentation of the room temperature and relative humidity for the above listed 73 days. The laboratory provided no documentation to review. 4. Review of the Thermo Scientific King Fisher Duo Prime Technical Manual's Operating Conditions revealed the following instrument environmental/operating requirements, "Operating Conditions (indoor use) +4C to +40C (104F); the maximum relative humidity 80% for temperatures up to 31C decreasing linearly to 50% relative humidity at 40C." Review of the Applied Biosystems QuantStudio 6 and 7 flex real-time PCR Manual revealed the following: Environmental requirements-Humidity 15-80% (non-condensing), Temperature 15- 30C (60-85F). 5. In an exit interview with the quality technical supervisor and technical supervisor on October 31, 2023, at approximately 1:00 PM, the findings were confirmed. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access