Citation History (2 surveys)

Survey - May 17, 2022

Survey Type: Standard

Survey Event ID: 5XA611

Deficiency Tags: D2009 D5807

Summary:

Summary Statement of Deficiencies D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) from the provider American Proficiency Institute (API) performed in 2020 and 2021 and interview with Chief Operations Officer (COO) revealed that the LD or approved designee failed to attest on seven events that proficiency testing samples were handled in the same manner as patient samples at time of survey. Findings: 1. Review of the attestation pages for PT from API revealed no signature of the LD or approved designee was present on API 2020 events: a. Chemistry Core 2nd Event b. Hematology / Coagulation 3rd Event c. Microbiology 2nd Event d. Chemistry Miscellaneous 1st Event 2. Review of the attestation pagers for PT from API revealed no signature of the LD or approved designee was present on API 2021 events: a. Hematology / Coagulation 2nd Event b. Microbiology 3rd Event c. Chemistry Miscellaneous 2nd Event 2. Interview with the COO on 5/17/2022 at 11:50 a.m. confirmed, the laboratory director (LD) or approved designee failed to attest on seven events that proficiency testing samples were handled in the same manner as patient samples at time of survey. D5807 TEST REPORT CFR(s): 493.1291(d) Pertinent "reference intervals" or "normal" values, as determined by the laboratory performing the tests, must be available to the authorized person who ordered the tests and, if applicable, the individual responsible for using the test results. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on review of approved reference ranges in the laboratory "Reference Range" procedure manual and interview with the Chief Operations Officer (COO), the laboratory failed to ensure the test report included pertinent age and gender normal ranges as determined by the laboratory "Reference Range" policy at time of survey. Findings: 1. Review of the patient reports from the Laboratory Information System (LIS) revealed thirteen parameters for normal ranges did not correctly match those reference ranges for the complete blood count (CBC) test in the laboratory "Reference Range" procedure manual. LIS patient report: (Unisex/No age specifics) WBC 5.0- 10.0 10^3/uL RBC 4.7-6.1 10^6/uL HGB 14.0-18.0 g/dL HCT 42.0-52.0 % MCV 80.0-95.0 fL MCH 27.0-31.0 pg MCHC 32.0-36.0 g/dL PLT 150-450 10^3/uL NEUT% 55.0-70.0 % LYM% 20.0-40.0 % MON% 2.0-8.0 % EOS% 1.0-4.0 % BAS% 0.5-1.0 % Procedure Manual Parameters: (Female Adult >21 y/o) (Male Adult >21 y/o) WBC 3.98-10.04 10^3/uL 4.23-9.07 10^3/uL RBC 3.93-5.22 10^6/uL 4.63- 6.08 10^6/uL HGB 11.2-15.7 g/dL 13.7-17.5 g/dL HCT 34.1-44.9 % 40.1-51.0 % MCV 79.4-94.8 fL 79.0-92.2 fL MCH 25.6-32.2 pg 25.7-32.2 pg MCHC 32.2-35.5 g /dL 32.3-36.5 g/dL PLT 182-369 10^3/uL 163-337 10^3/uL NEUT% 34.0-71.1 % 34.0-67.9 % LYM% 19.3-51.7 % 21.8-53.1 % MON% 4.4-12.5 % 5.3-12.2 % EOS% 0.7-5.8 % 0.8-7.0 % BAS% 0.1-1.2 % 0.2-1.2 % 2. Interview with COO on 5/17/2022 at 11:50 a.m. confirmed, the laboratory failed to ensure the correct reference ranges approved in the "Reference Range" procedure manual were in correlation with the LIS patient report. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 2, 2020

Survey Type: Standard

Survey Event ID: 4ZLP11

Deficiency Tags: D5431

Summary:

Summary Statement of Deficiencies D5431 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(2) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document function checks as defined by the manufacturer and with at least the frequency specified by the manufacturer. Function checks must be within the manufacturer's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: Based on an absence of pipette records, microscope maintenance records and interview with General Supervisor (GS) #1, the laboratory failed to perform and document function checks for eight of eight pipettes and two of two microscopes. Findings were: 1. No documentation was available for function checks of pipettes for period between 09/12/2018 to 12/31/2019. No documentation was available for the certification of accuracy for eight of eight pipettes for 2019. 2. No documentation was available for the maintenance of two of two microscopes for period between 09/12 /2018 to 09/02/2020. 3. Interview with GS#1 on 09/02/2020 @11:20 am confirmed the laboratory had no records of function checks or certification of accuracy for the eight pipettes used in the laboratory for the period between 09/12//2018 to 12/31 //2019. 4. Interview with GS#1on 09/02/2020 @11:25 confirmed the laboratory had no records of microscope maintenance for two of two microscopes during the 24 month period. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --