Primary Pediatrics, Bonaire

CLIA Laboratory Citation Details

5
Total Citations
26
Total Deficiencyies
16
Unique D-Tags
CMS Certification Number 11D2160839
Address 104 Bluff Chase, Suite A, Bonaire, GA, 31005
City Bonaire
State GA
Zip Code31005
Phone478 336-1980
Lab DirectorCHRISTOPHER CAWLEY

Citation History (5 surveys)

Survey - November 24, 2025

Survey Type: Special

Survey Event ID: 54JZ11

Deficiency Tags: D0000 D2016 D2130 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on November 24, 2025. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following condition deficiencies were cited: D2016 - 42 CFR 493.803 Condition: Successful participation [proficiency testing] D6000 - 42 CFR 493.1403 Condition: Moderate Complex Laboratory Director D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the CASPER 155 report and review of the American Proficiency Institute (API) reports, the laboratory failed to maintain satisfactory proficiency Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- testing (PT) participation for Red Blood Cell (RBC) in 2024 event 3 and 2025 event 2, resulting in an initial unsuccessful participation for RBC.. Refer to D 2130 D2130 HEMATOLOGY CFR(s): 493.851(f) (f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Centers for Medicare and Medicaid (CMS) CASPER 155 report and review of American Proficiency Institute (API) reports, the laboratory failed to maintain satisfactory participation in two of three testing events ( 3rd event of 2024 and 2nd event of 2025), resulting in an initial unsuccessful participation for RBC. Findings: 1. A review of Casper Report 155 revealed the laboratory failed RBC on the following: 2024 Event 3 RBC Score 60% 2025 Event 1 RBC Score 20% 2. A review of the laboratory's API Reports confirmed the laboratory failed RBC with the aforementioned scores. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on review of the CMS CASPER 155 report and review of American Proficiency Institute (API) reports, the laboratory director failed to provide overall management and direction for proficiency testing performance. The laboratory director failed to ensure proficiency testing samples were tested as required. Refer to D6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on review of the CMS CASPER Report 155 and the American Proficiency Institute (API) 2024 event 3 and 2025 event 2 PT evaluation reports, the laboratory director failed to ensure successful proficiency testing performance in RBC in two of three testing events resulting in the initial unsuccessful participation for RBC. 1. A review of Casper Report 155 revealed the laboratory failed RBC on the following: 2024 Event 3 RBC Score 60% 2025 Event 1 RBC Score 20% 2. A review of the laboratory's API Reports confirmed the laboratory failed RBC with the aforementioned scores. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 24, 2025

Survey Type: Standard

Survey Event ID: 0UMH11

Deficiency Tags: D0000 D3003 D5403 D5455 D5479 D6004 D6020 D6046

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) Recertification Survey was completed on October 24, 2025. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D3003 FACILITIES CFR(s): 493.1101(a)(2) (a)(2) Contamination of patient specimens, equipment, instruments, reagents, materials, and supplies is minimized. This STANDARD is not met as evidenced by: A tour of the laboratory facility revealed that the laboratory did not minimize risks of potential cross contamination. THE FINDINGS INCLUDE: 1. A tour of the laboratory facility revealed the following: a. A separate Clean Sink was not available to testing personnel. b. The Eyewash Station was mounted on the Dirty Sink. 2. An exit interview, with Testing Personnel, on October 24, 2025, at 2:00 pm, in Break Room confirmed that the laboratory did not minimize risks of potential cross contamination. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) (b) The procedure manual must include the following when applicable to the test procedure: (b)(1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (b)(2) Microscopic examination, including the detection of inadequately prepared slides. (b)(3) Step-by- step performance of the procedure, including test calculations and interpretation of results. (b)(4) Preparation of slides, solutions, calibrators, controls, reagents, stains, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- and other materials used in testing. (b)(5) Calibration and calibration verification procedures. (b)(6) The reportable range for test results for the test system as established or verified in 493.1253. (b)(7) Control procedures. (b)(8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 29, 2023

Survey Type: Standard

Survey Event ID: 54HU11

Deficiency Tags: D0000 D5413 D5477 D6000 D6024

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was performed on August 29, 2023. The facility was found to be NOT in compliance with all applicable CLIA requirements for specialties /subspecialties for 42 CFR. Condition Level D6000 - Director Oversite 149.1407 D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of the Daily Environmental Log (DEL) and staff interview, the laboratory failed to provide documentation of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 28, 2022

Survey Type: Special

Survey Event ID: 5RSG11

Deficiency Tags: D0000 D2016 D2130 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on February 28, 2022. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two of three consecutive events (1st event of 2016 and 3rd event of Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- 2016), resulting in the first unsuccessful occurrence for Hematology # 760 including: cell ID or WBC differential (DIFF) # 765. Findings include: Refer to D 2130 D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports from the American Proficiency Institute (API), the laboratory failed to maintain satisfactory performance in two consecutive events (1st and 3rd events of 2021), resulting in the first unsuccessful occurrence for WBC DIFF #765. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte WBC DIFF #765 event #1 and #3 of 2021 with a score of 0%. 2. Desk review of the laboratory's proficiency testing reports from API confirms the laboratory failed WBC DIFF #765 on events 1 and 3 of 2021 resulting in the first unsuccessful performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two of three consecutive events (1st and 3rd events of 2021), resulting in the first unsuccessful occurrence for WBC DIFF #765. Findings include: Refer to D 6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory -- 2 of 3 -- maintained satisfactory performance in two of three consecutive events (1st and 3rd events of 2021), resulting in the first unsuccessful occurrence for WBC DIFF #765. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte WBC DIFF #765 on event 1 of 2021 with a score of 0% and event 3 of 2021 with a score of 0%. 2. Desk review of the laboratory's proficiency testing reports from American Proficiency Institute (API) confirmed the laboratory failed WBC DIFF #765 on Events 1 and 3 of 2021, resulting in the first unsuccessful performance. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 26, 2021

Survey Type: Standard

Survey Event ID: N0MK11

Deficiency Tags: D0000 D5439 D6004

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) Recertification survey was completed on October 25, 2021. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on review of the calibration documents for the Cell Dyn Emerald (Emerald), Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- and staff interview, the laboratory failed to perform calibration every six months. Findings: 1. Review of the calibration documents, the laboratory performed calibration on the Emerald the following dates: 09/2021 03/2021 02/2020 (13 months) 2. Interview with staff #2 (CMS 209), and the Lab Manager, on October 26, 2021 at approximately 12:30 pm in the breakroom, confirmed the aforementioned documentation. D6004 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(a)(b) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (a) The laboratory director, if qualified, may perform the duties of the technical consultant, clinical consultant, and testing personnel, or delegate these responsibilities to personnel meeting the qualifications of 493.1409, 493.1415, and 493.1421, respectively. (b) If the laboratory director reapportions performance of his or her responsibilities, he or she remains responsible for ensuring that all duties are properly performed. This STANDARD is not met as evidenced by: Based on review of the calibration documents for the Cell Dyn Emerald (Emerald), and staff interview, the Laboratory Director (LD) failed to verify the calibration for the Emerald was perform every six months. Findings: 1. Review of the calibration documents, the laboratory performed calibration on the Emerald the following dates: 09/2021 03/2021 02/2020 (13 months) 2. Interview with staff #2 (CMS 209), and the Lab Manager, on October 26, 2021 at approximately 12:30 pm in the breakroom, confirmed the aforementioned documentation. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access