Psmg-Red Rose Pediatrics

CLIA Laboratory Citation Details

1
Total Citation
5
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 39D0888484
Address 233 College Avenue, Lancaster, PA, 17603
City Lancaster
State PA
Zip Code17603
Phone(717) 291-8512

Citation History (1 survey)

Survey - March 14, 2018

Survey Type: Standard

Survey Event ID: 6D3N11

Deficiency Tags: D6018 D6022 D6022 D5477 D6018

Summary:

Summary Statement of Deficiencies D5477 CONTROL PROCEDURES CFR(s): 493.1256(e)(4)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (4) Before, or concurrent with the initial use-- (e)(4)(i) Check each batch of media for sterility if sterility is required for testing; (e)(4)(ii) Check each batch of media for its ability to support growth and, as appropriate, select or inhibit specific organisms or produce a biochemical response; and (e)(4)(iii) Document the physical characteristics of the media when compromised and report any deterioration in the media to the manufacturer. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of media quality control records and interview with the Clinical Supervisor, the laboratory failed to check each batch of Uricult CLED/EMB media used for urine cultures, for sterility and ability to support growth in 2017 to the date of survey. Findings Include: 1. On the date of survey, 03/14/2018, after review of media quality control, it was discovered that the laboratory did not perform quality control on the Uricult CLED/ EMB media. 2. The laboratory reports out growth or no growth and in 2017, about 600 specimen were reported. 3. The Clinical Supervisor confirmed the findings above on 03/04/2018 2:00 PM. D6018 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iii) Ensure that all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access