Public Health And Environmental

CLIA Laboratory Citation Details

3
Total Citations
20
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 31D0881184
Address 3 Schwarzkopf Drive, Ewing, NJ, 08628
City Ewing
State NJ
Zip Code08628

Citation History (3 surveys)

Survey - November 2, 2023

Survey Type: Standard

Survey Event ID: 31ZX11

Deficiency Tags: D0000 D5413 D5417 D5429 D0000 D5413 D5417 D5429

Summary:

Summary Statement of Deficiencies D0000 The Centers for Medicare & Medicaid Services (CMS) CLIA Branch Location federal surveyors conducted an announced CLIA recertification survey of the New Jersey Public Health and Environmental Laboratory on October 31, 2023 to November 2, 2023. The laboratory was surveyed under 42 CFR part 493 CLIA requirements. The following deficiencies were found during the announced routine CLIA recertification survey performed October 31, 2023 to November 2, 2023. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of the laboratory temperature and humidity records and interview with the Quality Assurance Coordinator and technical supervisor (TS) #5, the laboratory failed to define low humidity criteria for the virology laboratory from 2022 to the day of survey. Findings Include: 1. The PHEL Temperature and Humidity Logs for laboratories L315, L320A and L320B state humidity range Less than or equal to 75%. 2. A sampling of instrument manufacturer documents Environmental Conditions - Relative Humidity's stated: - EPlex = 15 - 85%. - Panther Hologic = 20 - 85%. - Vidas = 15 - 85%. - GeneXpert = 15 - 85%. 3. Review of The PHEL Temperature and Humidity Logs for laboratories L315, L320A and L320B from 2022 to 2023 on November 2, 2023, revealed there were no established low limits for Humidity. 4. The following months in 2022 and 2023 the PHEL Temperature and Humidity Logs for Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- laboratories L315, L320A and L320B stated humidity "low" and not an actual measured humidity %: 2022: - L315: January, February, March April, May, October, November and December. - L320A: January, May and November. - L320B: January, October and November. 2023: - L315: January, February, March April, May and June. - L320A: January, February and May. - L320B: February, April and May. 5. The Quality Assurance Coordinator and TS#5 confirmed a low Humidity limit had not been established for the laboratories from January 2022 to November 2023. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on a review of the oxidase reagent quality control (QC) records and interview with the Quality Assurance Coordinator, the laboratory failed to not use an expired lot of oxidase reagent made in house from April 2023 to May 2023. Findings Include: 1. The oxidase reagent was made in house on April 5, 2022 and expired on April 5, 2023. 2. Review of the oxidase reagent QC records on October 31, 2023 revealed, the oxidase reagent (Lot# 076K18141) was used past its expiration date (April 5, 2023), as the April and May of 2023 oxidase reagent QC logs stated the reagent expiration date as May 5, 2023. 3. The laboratory was unable to provide documentation as to why the reagents expiration date was extended to May 5, 2023. 4. The oxidase reagent was used for two patients in April 2023 and five patients in May of 2023. 5. The Quality Assurance Coordinator confirmed no documentation was available to support the extension of the expiration date of the oxidase reagent on November 2, 2023 at 11: 45 am. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on record review, observations, and interviews with TP#18, the laboratory failed to perform maintenance at the frequency specified by the manufacturer. Findings include: 1. The instructions for use for the SPH1240 states: "To keep the SPH1240 in optimal condition, preventative maintenance is required at regular intervals but at least one time per year." 2. During a tour of the laboratory on November 2, 2023 at 11:10 am, it was noted that the SPH1240 maintenance sticker had a preventative maintenance performance date of 30 Aug 2022 and an expiration date of 29 Aug 2023. 3. During an interview on November 2, 2023 at 11:10 am, TP#18 confirmed that the preventative maintenance was overdue for the SPH1240. 4. During a tour of the laboratory on November 2, 2023 at about 11:30 am, it was noted that the 7500-2 preventative maintenance was due on 10/1/2023. 5. During an interview on November 2, 2023 at about 11:30 am, TP#18 confirmed that the 7500-2 preventative maintenance was overdue. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 2, 2021

Survey Type: Standard

Survey Event ID: BZJT11

Deficiency Tags: D0000 D5407 D5467 D5781 D5407 D5467 D5781

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was performed at the New Jersey Public Health and Environmental Laboratories on November 30, 2021 to December 2, 2021 by the CMS New York CLIA Branch Location federal surveyor. The laboratory was surveyed under 42 CFR part 493 CLIA regulations. The specific deficiencies are as follows: D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on review of standard operating procedures (SOP) and an interview with the testing person, the Field Deployable Laboratory (FDL) failed to provide an approved procedure manual for the Cepheid GeneXpert Xpress SARS- CoV-2/Flu/RSV Assay . Findings include: 1. On December 1, 2021 at approximately 2:30 PM ,during a review of procedure manual documentation the surveyor requested the SOP for the Cepheid GeneXpert Xpress SARS-CoV2/Flu/RSV assay. 2. The FDL Testing Person (TP1) stated "An element still has to be added for the procedure to be finalized". 3. During the exit interview with the laboratory director on December 2, 2021 at 5:00 pm confirmed the above findings. D5467 CONTROL PROCEDURES CFR(s): 493.1256(d)(9)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- When using calibration material as a control material, use calibration material from a different lot number than that used to establish a cut-off value or to calibrate the test Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- system. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on lack of documentation and interview with testing person, the Field Deployable Laboratory (FDL) section of the virology program failed to perform verification of the lot number for control materials for GeneXpert cartridges prior to the use for testing. Findings include: 1. On December 2, 2021 during a tour of the storage facility for the Field Deployable Laboratory (FDL) section of the virology program, the surveyor observed multiple GeneXpert Cartridge kits used for the Cepheid GeneXpert Xpress SARS- CoV-2/Flu/RSV Assay and inquired how does the laboratory verify the acceptability of the control materials? 2. The FDL Testing Person (TP1) stated " we don't perform kit lot to lot studies ". The absence of control verification documents verified the TP statement. 3. During the exit interview with the laboratory director on December 2, 2021 at 5:00 pm confirmed the above findings. D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 28, 2019

Survey Type: Standard

Survey Event ID: XO7111

Deficiency Tags: D5209 D5413 D5445 D5413 D5445

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on lack of documentation and confirmation by the Quality Assurance officer, the laboratory failed to follow its written policies and procedures to assess the competency of eleven of eleven general and technical supervisors for calendar year 2018. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on reviewing the April 2019 temperature and humidity log book located in the New Born Screening test area and confirmation by a testing personnel, the laboratory failed to take

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access