Purohit Pediatric Clinic Roanoke

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 01D2044942
Address 4441 Highway 431, Suite 1, Roanoke, AL, 36274
City Roanoke
State AL
Zip Code36274
Phone334 863-2553
Lab DirectorNARESH PUROHIT

Citation History (2 surveys)

Survey - August 26, 2025

Survey Type: Standard

Survey Event ID: Q5LW11

Deficiency Tags: D0000 D5215

Summary:

Summary Statement of Deficiencies D0000 A desk review, follow-up survey was conducted on 09-05-2025. Based on a review of an acceptable

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 26, 2021

Survey Type: Standard

Survey Event ID: SKS211

Deficiency Tags: D2007 D5793

Summary:

Summary Statement of Deficiencies D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods This STANDARD is not met as evidenced by: Based on a review of the American Proficiency Institute (API) proficiency testing records, a review of the quality control records and an interview with the laboratory manager, the surveyor determined the laboratory failed to rotate the testing of proficiency specimens, among all personnel who test patient specimens [Complete Blood Counts (Hematology)]. This affected 8 of 8 Hematology testing events from 2018 (Event #3), 2019 and 2020 (six events), and 2021(Event #1). The findings include: 1. A review of API proficiency testing records revealed Testing Personnel (TP) #1 signed the attestation statements for all eight Hematology testing events from 2018 (Event #3) - 2021 (Event #1). 2. The laboratory staff listed the same three qualified and trained individuals on the CMS form #209 (Laboratory Personnel Report) as on the previous survey conducted 12/19/2018. 3. At 10:55 AM on May 26, 2021, the surveyor asked the laboratory manager (also listed as TP #3) about proficiency testing rotation, inquiring if TP #1 was the only personnel who perform Hematology testing. The laboratory manager stated TP #1 was the primary testing personnel, although TP #2 was usually on-site, and assisted with laboratory testing (CBC testing), when the laboratory is busy. TP #3, the laboratory manager, usually worked another location. The laboratory manager stated the testing would be rotated. 4. A review of the quality control records, from 2019 - 2021, revealed TP #2 performed testing on the Hematology analyzer. D5793 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(b)(c) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (b) The analytic systems quality assessment must include a review of the effectiveness of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access