Qugene Scientific Llc

CLIA Laboratory Citation Details

1
Total Citation
1
Total Deficiency
1
Unique D-Tag
CMS Certification Number 14D2272104
Address 1525 Bourbon Pkwy, Streamwood, IL, 60107
City Streamwood
State IL
Zip Code60107
Phone(630) 942-1520

Citation History (1 survey)

Survey - October 9, 2024

Survey Type: Standard

Survey Event ID: UXKB11

Deficiency Tags: D5423

Summary:

Summary Statement of Deficiencies D5423 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(2) Each laboratory that modifies an FDA-cleared or approved test system, or introduces a test system not subject to FDA clearance or approval (including methods developed in-house and standardized methods such as text book procedures), or uses a test system in which performance specifications are not provided by the manufacturer must, before reporting patient test results, establish for each test system the performance specifications for the following performance characteristics, as applicable: (2)(i) Accuracy. (2)(ii) Precision. (2)(iii) Analytical sensitivity. (2)(iv) Analytical specificity to include interfering substances. (2)(v) Reportable range of test results for the test system. (2)(vi) Reference intervals (normal values). (2)(vii) Any other performance characteristic required for test performance. This STANDARD is not met as evidenced by: Based on direct observation, review of laboratory records, lack of documentation, and interview with testing personnel (TP) #1; the laboratory failed to establish the performance specifications for one of one laboratory developed test (LDT), Sperm DNA Fragmentation (SDF), on the BD FACSCalibur instrument (Serial Number: E5253) prior to reporting patient results, affecting 58 patients from 12/20/2022 to the survey date, 10/09/2024. Findings include: 1. Review of laboratory records revealed the laboratory failed to perform a verification of performance study for SDP testing prior to patient testing. The laboratory failed to address the following characteristics of a verification of performance study for the LDT SDP: a. Accuracy. b. Precision. c. Analytical sensitivity. d. Analytical specificity to include interfering substances. e. Reportable range of test results for the test system. f. Reference intervals (normal values). g. Any other performance characteristic required for test performance. 2. Review of laboratory testing records found 58 patient tests were reported for SDP Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- from 12/20/2022 to the survey date, 10/09/2024. 3. Interview with TP #1 on 10/09 /2024, at 12:43 pm, confirmed the laboratory failed to establish the performance specifications for one of one LDT, SDF, prior to reporting patient results. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access