Rainbow Pediatrics Of Fayetteville

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 34D2273022
Address 341 S Mcpherson Church Rd, Fayetteville, NC, 28303
City Fayetteville
State NC
Zip Code28303
Phone910 920-4428
Lab DirectorTANER ESENSOY

Citation History (2 surveys)

Survey - February 11, 2026

Survey Type: Special

Survey Event ID: WO0U11

Deficiency Tags: D2016 D6000 D2130 D6016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS (Centers for Medicare and Medicaid Services) Casper reports 153D and 155D and 2025 API (American Proficiency Institute) proficiency testing results, the laboratory failed to successfully participate in proficiency testing for Hematocrit on two consecutive test events in 2025. Refer to D2130. D2130 HEMATOLOGY CFR(s): 493.851(f) (f) Failure to achieve satisfactory performance for the same analyte in two consecutive Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS Casper reports 153D and 155D and 2025 API proficiency testing results, the laboratory failed to achieve satisfactory performance for the analyte Hematocrit on two consecutive testing events, resulting in unsuccessful performance. Findings: 1. Review of CMS Casper reports revealed the following scores: a. 2025 Event 2 = 60% b. 2025 Event 3 = 60% 2. Review of API proficiency testing results for these events confirmed the above scores. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on desk review of CMS Casper reports 153D and 155D and 2025 API proficiency testing results, the laboratory director failed to provide overall management and direction to ensure successful proficiency testing participation. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) (e)(4)(i) The proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on desk review of CMS Casper reports 153D and 155D and 2025 API proficiency testing results, the laboratory director failed to ensure successful participation in proficiency testing as required in Subpart H. Refer to D2130. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 24, 2025

Survey Type: Standard

Survey Event ID: QIBI11

Deficiency Tags: D2007 D2007

Summary:

Summary Statement of Deficiencies D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) (b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on review of laboratory procedures, review of 2024 and 2025 American Proficiency Institute (API) Proficiency Testing (PT) records, and interview with Testing Personnel (TP #7) 11/24/25, the laboratory failed to ensure all TP who performed Complete Blood Count (CBC) testing participated in PT. Findings: Review of "Standard Operating Procedures (SOPS)" revealed, "...Test proficiency samples... using a staff member who routinely performs hematology testing. Rotate PT duties amongst all personnel who test samples..." Review of API 2024 and 2025 PT records revealed: 1. API 2024 - 2 of 8 TP participated in events 1-3: TP #1 tested all samples in events 1 and 3. TP #6 tested all samples in event 2. 2. API 2025 - 3 of 7 TP participated in events 1-3: TP #1 tested all samples in event 2. TP #2 tested all samples in event 3. TP #5 tested all samples in event 1. Interview at approximately 1: 45 p.m. TP #7 confirmed all TP did not participate in PT. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access