Regional Pathologists, Inc

CLIA Laboratory Citation Details

3
Total Citations
16
Total Deficiencyies
14
Unique D-Tags
CMS Certification Number 31D1065892
Address 140 Sylvan Avenue, Englewood Cliffs, NJ, 07632
City Englewood Cliffs
State NJ
Zip Code07632
Phone(201) 292-1437

Citation History (3 surveys)

Survey - October 8, 2024

Survey Type: Standard

Survey Event ID: EXQW11

Deficiency Tags: D3009 D5315 D5417 D5461 D5805 D5291 D5391 D5445 D5469 D6091 D6093

Summary:

Summary Statement of Deficiencies D3009 FACILITIES CFR(s): 493.1101(c) The laboratory must be in compliance with applicable Federal, State, and local laboratory requirements. This STANDARD is not met as evidenced by: Based on surveyor review of the laboratories New Jersey (NJ) State License, Proficiency Testing (PT) and interview with the Technical Supervisor (TS) the laboratory failed to be in compliance with NJ Administrative code N.J.A.C. 8:44-2.5 (b)3. for calendar years 2023 and 2024. The finding includes: 1. N.J.A.C. 8:44-2.5(b) 3. states Laboratories shall: iii. Maintain records of all proficiency testing results in surveys in which they participate and make such records, including results, interpretations and cumulative performance data routinely available to the Department of Health and Senior Services. 2. Review of the PT records for all PT events in 2023 and 2024 revealed that the reports were only copied to Centers for Medicare and Medicaid Services (CMS) and New York State Department of Health and not the NJ Department of Health and Senior Services. 3. The TS confirmed on 10/8/24 at 11:30 am the laboratory failed to make PT performance data for Immunology, Urinalysis, Bacteriology, Parasitology and Virology routinely available to the NJ Department of Health and Senior Services. D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual and interview with the Techincal Supervisor (TS), the laboratory failed to establish a detailed procedure for Biannual Assessment (BA) from 6/8/22 to 10/8/24. The TS confirmed on 6/8/22 at 1:15 pm t laboratory did not have a BA procedure.. D5315 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(c) The laboratory must refer a specimen for testing only to a CLIA-certified laboratory or a laboratory meeting equivalent requirements as determined by CMS. This STANDARD is not met as evidenced by: Based on surveyor review of Final Reports (FR), Histopathology records and interview with the Techincal Supervisor (TS) the laboratory referred the evaluation of histopathology slides to a non-CLIA-certified laboratory from 6/8/22 to 10/8/24. The TS confirmed on 10/8/24 at 12:45 pm that histopathology slides were reviewed and resulted from a non-CLIA-certified laboratory. D5391 PREANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1249(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the preanalytic systems specified at 493.1241 through 493.1242. This STANDARD is not met as evidenced by: Based on surveyor review of the laboratories Individualized Quality Control Plan (IQCP) for Bacteriology, mycology parasitology, and virology tests performed on the Bio-fire analyzer and interview with the Technical Supervisor (TS), the laboratory failed to monitor, assess, and when indicated, correct problems identified in the preanalytic system from 6/8/22 to 10/8/24. The finding includes. 1. The Quality Assesment did not establish written policies and procedures for the frequency in which the QA monitors the Quality Control Plan (QCP). 2. The TS confirmed on 10/8 /24 at 12:00 PM that the laboratory failed to establish written policies and procedures for the frequency in which the QA monitors the QCP. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on surveyor observation of Acetic Acid 3% reagent and interview with the Techincal Supervisor (TS), the laboratory failed to discard expired reagents from 5/31 -- 2 of 5 -- /2024 to 10/8/24. The findings include: 1. Avantik Acetic Acid, 3% Lot # 171358 expired 5/3/2024 2. Approximately 200 patients were run and reported 3. The TS confirmed on 10/8/24 at 10:30 am that the laboratory used expired reagent. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on the surveyor review of an Individualized Quality Control Plan (IQCP) and interview with the Techincal Supervisor (TS) the laboratory failed to perform a Risk Assesment (RA) on Testing Personnel TP) as required for testing performed on the Bio-fire analyzer from 6/8/22 to 10/8/24. The findings include: 1) There was no documented evidence that an RA on TP was performed in the IQCP used for the Bio- fire analyzer. 3) The TS confirmed on 10/8/24 at 11:00 am the laboratory failed to have the above mention RA in an approved IQCP for the Bio-fire analyzer. D5461 CONTROL PROCEDURES CFR(s): 493.1256(d)(6)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Perform control material testing as specified in this paragraph before resuming patient testing when a complete change of reagents is introduced; major preventive maintenance is performed; or any critical part that may influence test performance is replaced. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: a) Based on surveyor review of the Procedure Manual (PM), and interview with the Technical Supervisor(TS), the laboratory failed to perform and document lot to lot verification for Bacteriology, mycology parasitology, and virology tests performed on the Bio-fire analyzer analyzer from 6/9/22 to 10/8/24. The findings include: 1. There was no documented evidence lot to lot verification was performed on FilmArray GI control panels. 2. The TS confirmed on 10/8/24 at 12:10 pm, the laboratory failed to perform lot to lot verification on all FilmArray GI control panels. 48354 B) Based on surveyor review of the Procedure Manual (PM), Urinalysis Lot to Lot Test Log (ULL) and interview with the Technical Supervisor(TS), the laboratory failed to perform and document lot to lot verification for Urinalysis tests performed on the Arkray 4030 analyzer from 10/1/24 to 10/8/24. The findings include: 1. There was no documented evidence lot to lot verification was performed on Aution Arkray test strips lot # 9EB4B27. 2. The TS confirmed on 10/8/24 at 12:10 pm, the laboratory failed to perform lot to lot verification on all Aution Arkray test trips. -- 3 of 5 -- D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on the lack of Quality Control Verification (QCV) records and interview with the Technical Supervisor, the laboratory failed to verify commercially assayed QC material with each new lot and/or shipment used on the IQ200 and Arkay 4030 for Urinalysis testing from 6/8/22 to 10/8/24. The finding includes: 1. There were no QCV records available for review for the IQ200 and Arkray 4030. 2. The TS confirmed on 10/8/24 at 12:20 pm, the assayed values of QC material were not verified before patient testing. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on surveyor review of the Test Reports (TR) for Bacteriology, mycology, parasitology, and virology tests performed on the Bio-fire analyzer and interview with the Technical Supervisor (TS) the laboratory failed to ensure the TR included all the required information from 6/8/22 to 10/8/24. The findings include: 1. TR did not include the address of the elaborately where testing was performed. 2. The TS confirmed on 10/8//24 at 12:00 pm, the laboratory failed to ensure the TR included all the required information. D6091 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(iii) The laboratory director must ensure all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to -- 4 of 5 -- identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 8, 2022

Survey Type: Standard

Survey Event ID: S74511

Deficiency Tags: D6103 D3043 D5469 D6086

Summary:

Summary Statement of Deficiencies D3043 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(7) The laboratory must retain cytology slide preparations for at least 5 years from the date of examination (see 493.1274(f) for proficiency testing exception). The laboratory must retain histopathology slides for at least 10 years from the date of examination. The laboratory must retain pathology specimen blocks for at least 2 years from the date of examination. The laboratory must preserve remnants of tissue for pathology examination until a diagnosis is made on the specimen. This STANDARD is not met as evidenced by: Based on surveyor review of the Accession Log (AL), Histopathology Slides (HS) and interview with the Clinical Consultant (CC), the laboratory failed to retain HS from 2020. The finding includes: 1. A review of five patient records found on the AL between April 2021 to the date pf survey revealed that one of five patient Quality Control slides was not available at the time of the survey. 2. The CC confirmed on 6/6 /22 at 12:15 pm the HS were not retained. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor review of the Quality Control (QC) records and interview with the Clinical Consultant (CC), the laboratory failed to verify that the assayed QC material were within the acceptable ranges before they were put into use for tests performed on the Iris Plus iQ200 elite, Aution May AX-4030 and Biofire FilmArray Torch analyzers from April 2020 to the date of survey. The CC confirmed on 6/6/22 at 1:10 pm that the laboratory did not verify QC material. D6086 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(3)(ii) The laboratory director must ensure that verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method. This STANDARD is not met as evidenced by: Based on surveyor review of the Performance Specification (PS) records and interview with the Clinical Consultant (CC), the LD failed to ensure that PS were adequate to perform Chemistry tests performed on the Aution Max AX-4030 analyzers from April 2020 to the date of survey. The findings include: 1. The laboratory did not verify Patient Normal Range. 2. The CC confirmed on 6/6/22 at 11: 15 am that not all PS were adequate. D6103 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(13) The laboratory director must ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM) and interview with the Clinical Consultant (CC), the Laboratory Director failed to establish a Competency Assessment (CA) procedure with all applicable elements for testing personnel who perform Microbiology and Chemistry testing from April 2020 to the date of survey. The CC confirmed on 6/6/22 at 12:30 pm that a CA procedure was not established with all applicable elements. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 6, 2019

Survey Type: Standard

Survey Event ID: 1UDZ11

Deficiency Tags: D5805

Summary:

Summary Statement of Deficiencies D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on surveyor review of the Final Report (FR) and interview with the Laboratory Director (LD), the laboratory failed to ensure that the FR included the address of the laboratory location where testing was performed from 4/11/17 to the date of survey. The findings include: 1. A review of ten FR revealed the laboratory's address was listed under Physician Information below the Physician's name. 2. The LD confirmed on 3/6/19 at 1:50 pm that FR did not have all the required information. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access