Revere Health Provo Main Campus

CLIA Laboratory Citation Details

3
Total Citations
12
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 46D0700813
Address 1055 N 500 W, Provo, UT, 84604
City Provo
State UT
Zip Code84604
Phone(801) 812-5033

Citation History (3 surveys)

Survey - July 11, 2022

Survey Type: Standard

Survey Event ID: JN3511

Deficiency Tags: D5403 D5413 D5417 D5403 D5413 D5417

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 7, 2019

Survey Type: Standard

Survey Event ID: H1HD11

Deficiency Tags: D5217 D5439 D5217 D5439

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on lack of documentation and interview with staff, the laboratory failed to verify frozen section histopathology test accuracy at least twice annually in 2017 and 2018. The laboratory performed histopathology slide diagnosis on approximately 800 frozen sections per year. Findings include: 1. The laboratory lacked documentation they performed twice a year verification for frozen section histopathology testing in 2017 and 2018. 2. In an interview conducted on 08/07/2019 at approximately 10:40 A. M. staff confirmed the laboratory performed accuracy verification in 2019 for testing performed in previous years versus performing test accuracy verification twice annually in 2017 and 2018. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on calibration record review, lack of documentation and interview with staff, the laboratory failed to verify the reportable range for analytes without a 3 point calibration for the minimal, mid level and upper level of the reportable ranges for Sodium, Potassium, Chloride, Ammonia, Bilirubin, and Unsaturated Iron Binding Capacity tests for two six month periods in 2018. The laboratory performed approximately 800,000 tests per year for all chemistry sub-specialties. Findings include: 1. The laboratory failed to verify the reportable ranges for Sodium, Potassium, Chloride, Ammonia, Bilirubin, and Unsaturated Iron Binding Capacity tests at the zero or minimal level, at the mid-range level, and the upper level of the test's reportable ranges. 2. In an interview with the laboratory manger and the quality assurance manager on 08/07/2019 at approximately 5:45 P.M. staff confirmed the laboratory failed to verify the reportable ranges for tests that did not have calibration materials at the upper or lower levels of the reportable ranges. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 2, 2018

Survey Type: Standard

Survey Event ID: IE8Y12

Deficiency Tags: D6092 D6128

Summary:

Summary Statement of Deficiencies No Tags No deficiency details available. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility