Rheumatology Assocs Of North Jersey

CLIA Laboratory Citation Details

2
Total Citations
38
Total Deficiencyies
18
Unique D-Tags
CMS Certification Number 31D0113101
Address 1415 Queen Anne Road, Teaneck, NJ, 07666
City Teaneck
State NJ
Zip Code07666
Phone(201) 837-7788

Citation History (2 surveys)

Survey - June 11, 2024

Survey Type: Standard

Survey Event ID: Y4M111

Deficiency Tags: D5403 D5779 D5791 D5791 D6013 D6030 D6074 D5221 D5403 D5779 D6013 D6030 D6074

Summary:

Summary Statement of Deficiencies D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on surveyor review of Proficiency Testing (PT) results and interview with the General Supervisor (GS), the laboratory failed to review coded results for Celiac Serology testing performed with the College of American Pathologists (CAP) in 2023. The findings include: 1. The laboratory received a coded result "see note 27" for Celiac Serology event CES-A 2023 for Anti-gliadin IgG, specimen CES-02 and CES- 03. 2. The laboratory received a coded result "see note 26" for Celiac Serology event CES-A 2023 for Anti-tTG IgA, Qual specimen CES-01, 02, and 03. 3. There was no documented evidence that coded PT results were reviewed. 4. The GS confirmed on 6 /11/2024 at 1:15 pm that the laboratory did not review coded PT results. . D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 3, 2019

Survey Type: Standard

Survey Event ID: 1WFH11

Deficiency Tags: D3031 D5211 D5309 D5391 D5411 D5439 D5411 D5439 D5449 D5469 D5791 D5891 D6018 D5211 D5309 D5391 D5449 D5469 D5791 D5891 D6018 D6029 D6030 D6029 D6030

Summary:

Summary Statement of Deficiencies D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on surveyor review of Quality Control Results (QCR), observation in the Sysmex xp 300 analyzer and interview with the General Supervisor (GS), the laboratory failed to retain all unaccepted QCR from 11/28/17 to the date of survey. The GS confirmed on 4/3/19 at 1:15 pm tha all unaccepted QCR were not retained. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on surveyor review of the Proficiency Testing (PT) records and interview with the General Supervisor (GS), the laboratory failed to evaluate coded results obtained in CES-B 2018 Celiac Serology event with the College of American Pathologists (CAP). The findings include: 1. The laboratory did not evaluate Code 27 (lack of participant or referee consensus) and Code 26 (educational challenge) obtained in CES-B 2018 event. 2. The GS confirmed on 4/3/19 at 11:30 am that the laboratory failed to evaluate coded results for PT events in 2018. D5309 TEST REQUEST Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 6 -- CFR(s): 493.1241(e) If the laboratory transcribes or enters test requisition or authorization information into a record system or a laboratory information system, the laboratory must ensure the information is transcribed or entered accurately. This STANDARD is not met as evidenced by: Based on review of Test Requisition (TR), Laboratory Information System (LIS) and interview with the General Supervisor (GS), the laboratory failed to ensure that information from TR was transcribed accurately into the LIS for all tests from11/28 /17 to the date of the survey. The GS confirmed on 4/3/19nat 1:15 pm that the laboratory did not ensure information was transcribed accurately. D5391 PREANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1249(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the preanalytic systems specified at 493.1241 through 493.1242. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM) and interview with the General Supervisor (GS), the laboratory failed to established a written procedure on how transcribed information from test requisition into the laboratory information system will be monitored from 11/28/17 to the date of survey. The GS confirmed on 4 /3/19 at 1:00 pm that the laboratory did not have the procedure mentioned above. D5411 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(a) Test systems must be selected by the laboratory. The testing must be performed following the manufacturer's instructions and in a manner that provides test results within the laboratory's stated performance specifications for each test system as determined under 493.1253. This STANDARD is not met as evidenced by: Based on surveyor review of the Manufacturer's Pakage Insert (MPI), Final Report and interview with the General Supervisor (GS) on phone, the laboratory failed to follow MPI instruction for interpreting and reporting results from August 2018 to the date of survey. The finding includes: 1. Section Calculation and Test Interpretation, second paragraph stated concentration greater than 10 IU/ml reported as >10 but the laboratory reported for patient # 16974, >13.733 Mitogen value. 2. The GS confirmed on phone 4/3/19 that the laboartory did not follow MPI instructions. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; -- 2 of 6 -- (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on lack of Calibration Verification (CV) records and interview with the General Supervisor (GS), the laboratory failed to perform and document CV procedures at least once every six months for endocrinology tests performed on Access 2 from 11/28 /17 to the date of survey. The GS confirmed on 4/3/19 at 1:50 pm that CV was not performed every six months for tests performed on Access 2 analyzer. D5449 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(ii)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each qualitative procedure, include a negative and positive control material; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on lack of the Quality Control (QC) records and interview with the General Supervisor (GS), the laboratory failed to perform and document quality control for QuantiFERON-TB Gold Plus test from August 2018 to the date of the survey. The finding includes: 1. The laboratory did not perform positive and negative QC on each day of patient testing. 2. The laboratory ran and reported around six patient samples a week. 3. The GS confirmed on 4/3/19 at 1:15 pm that the laboratory did not perform and document quality control on each day of patient testing. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value -- 3 of 6 -- of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor review of the Quality Control (QC) records and interview with the General Supervisor (GS), the laboratory failed to verify that the assayed QC materials were within the acceptable ranges before they were put into use for tests performed on the Access 2, ACL-Alere, DSX and iSED analyzers from 11/28/17 to the date of survey. The GS confirmed on 4/3/19 at 12:30 pm that the laboratory did not verify QC materials for tests performed in the laboratory. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM), Quality Control (QC) records and interview with the General Supervisor (GS), the laboratory failed to establish a procedure to verify new QC material used in Endocrinology, Routine Chemistry and Hematology tests before put in use from 11/28/17 to the date of the survey. The GS confirmed on 4/3/19 at 12:10 pm the laboratory did not have a procedure to verify new QC material. D5891 POSTANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1299(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems specified in 493.1291. This STANDARD is not met as evidenced by: a) Based on surveyor review of the Procedure Manual and interview with the General Supervisor (GS), the laboratory failed to have a procedure to verify interfaced and calculated results into the laboratory information system from 11/28/17 to the date of the survey. The GS confirmed on 4/3/19 at 1:15 pm that the laboratory did not have the procedure mentioned above. b) Based on surveyor review of the Final report (FR) and interview with the GS, the laboartory failed to identify problem on FR from 11/28 /17 to the date of survey. The finding includes: 1. The "Receive On" date of specimen was after the result "Reported On" date. 2. The GS confirmed on 4/3/19 at 2:00 pm the the laboratory did not identify FR problem. c) Based on surveyor review of Mycobateriology Final report, Manufacturer's Package Instructions (MPI) and interview with the GS on phone, the laboratory failed to identify problem on FR from -- 4 of 6 -- August 2018 to the date of survey. The finding includes: 1. The laboratory reported 'Expected Values' for TB test but there were no expected values for the test in the MPI. 2. The GS confirmed on phone 4/3/19 at 2:00 pm the laboratory did not identify problem in reporting. D6018 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iii) Ensure that all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access