CLIA Laboratory Citation Details
33D0971664
Survey Type: Special
Survey Event ID: 3V8G11
Deficiency Tags: D2123 D2130 D6000 D6016 D2016 D2123 D2130 D6000 D6016
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on a proficiency testing (PT) desk review of the Center for Medicare and Medicaid Services (CMS) PT reports and PT records from the American Proficiency Institute (API) PT program, the laboratory failed to participate and perform successfully in a PT program, approved by CMS, for the test analyte Cell Identification (Cell I.D.)/White Blood Cell Differential (WBC Diff.) The following scores were assigned 2019 third event = 0% [non-participation] 2020 first event = 73% This is considered unsuccessful PT performance. Refer to D2130. D2123 HEMATOLOGY Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- CFR(s): 493.851(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on a PT desk review of the CMS PT reports and PT records from the API PT program, the laboratory failed to participate and perform successfully in a PT program, approved by CMS, for the specialty Hematology and the test analytes White Blood Cell Count (WBC), Red Blood Cell Count (RBC), Hematocrit (Hct), Hemoglobin (Hgb) and Platelets. The following scores were assigned: 2019 third event = 0% [non-participation] This is considered unsatisfactory PT performance. D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a PT desk review of the CMS PT reports and PT records from the API PT program, the laboratory failed to participate and perform successfully in a PT program, approved by CMS, for the test analyte WBC Diff. The following scores were assigned 2019 third event = 0% [non-participation] 2020 first event = 73% This is considered unsuccessful PT performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on PT desk review of the PT CMS data reports and API PT program records, the laboratory director failed to fulfill the laboratory director's responsibilities and ensure that the laboratory achieved a satisfactory performance and successfully participate in a PT program for the specialty Hematology and the test analytes WBC, RBC, WBC Diff., Hct, Hgb and Platelets. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) -- 2 of 3 -- The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on PT desk review of the PT CMS data reports and API PT program records, the laboratory director failed to fulfill the laboratory director's responsibilities and ensure that the laboratory achieved a satisfactory performance and successfully participate in a PT program for the specialty Hematology and the test analytes WBC, RBC, WBC Diff, Hct, Hgb and Platelets. The following scores were assigned WBC Diff/Cell I.D. 2019 third event = 0% [non-participation] 2020 first event = 73% This is considered unsuccessful PT performance. Specialty Hematology/WBC/RBC/Hgb /Hct and Platelets 2020 first event = 0% [non-participation] This is considered unsatisfactory PT performance. -- 3 of 3 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Special
Survey Event ID: UT4Z11
Deficiency Tags: D2123 D2130 D6000 D6016 D6016 D2016 D2123 D2130 D6000
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on a proficiency testing (PT) desk review of the Center for Medicare and Medicaid Services (CMS) PT reports and PT records from the American Proficiency Institute (API) PT program, the laboratory failed to participate and perform successfully in a PT program, approved by CMS, for the test analyte Hemoglobin (Hgb). The following scores were assigned: 2019 second event = 60% 2019 third event = 0% [non-participation] This is considered unsuccessful PT performance. Refer to D2130. D2123 HEMATOLOGY Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- CFR(s): 493.851(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on a PT desk review of the CMS PT reports and PT records from the API PT program, the laboratory failed to participate and perform successfully in a PT program, approved by CMS, for the specialty Hematology and the test analytes White Blood Cell Count (WBC), Red Blood Cell Count (RBC), WBC Diff, Hematocrit (Hct) and Platelets. The following scores were assigned: 2019 third event = 0% [non- participation] This is considered unsatisfactory PT performance. D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a PT desk review of the CMS PT reports and PT records from the American API PT program, the laboratory failed to participate and perform successfully in a PT program, approved by CMS, for the test analyte Hemoglobin (Hgb). The following scores were assigned: 2019 second event = 60% 2019 third event = 0% [non- participation] This is considered unsuccessful PT performance. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on PT desk review of the PT CMS data reports and API PT program records, the laboratory director failed to fulfill the laboratory director's responsibilities and ensure that the laboratory achieved a satisfactory performance and successfully participate in a PT program, for the specialty Hematology and test analytes WBC, RBC, WBC Diff, Hct, Hgb and Platelets. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) -- 2 of 3 -- The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on PT desk review of the PT CMS data reports and API PT program records, the laboratory director failed to fulfill the laboratory director's responsibilities and ensure that the laboratory achieved a satisfactory performance and successfully participate in a PT program, for the specialty Hematology and the test analytes WBC, RBC, WBC Diff., Hct, Hgb and Platelets. The following scores were assigned: Hgb 2019 second event = 60% 2019 third event = 0% [non-participation] This is considered unsuccessful PT performance Hematology and WBC, RBC, WBC Diff., Hct and Platelets. 2019 third event = 0% [non-participation] This is considered unsatisfactory PT performance. -- 3 of 3 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Standard
Survey Event ID: MP9Z11
Deficiency Tags: D5211 D5417 D5437 D5417 D5437 D5469 D5469
Summary Statement of Deficiencies D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on the surveyor's review of American Proficiency Institute (API) Proficiency Testing (PT) reports and an interview with the testing person, the laboratory failed to evaluate, perform and document remedial action for the PT scores of less than 100% for the following analytes: 2017 first event: Hematocrit = 80% Hemoglobin = 80% D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on a surveyor's review of the hematology quality Control (QC) records and an interview with the testing person, the laboratory failed to discontinue the use of the expired quality control materials. FINDINGS: 1. On June 29, 2018 at approximately 3: 30 PM the testing person confirmed surveyor's findings that the laboratory used 3 levels of expired QC for hematology analytes testing from 10/24/17 through 10/30/17. Low QC lot # 067500, normal QC lot 077500, high QC lot # 087500 expiration date 10/23/17. 2. Approximately 30 patients were tested for hematology using the expired quality control materials during the above time frame. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. This STANDARD is not met as evidenced by: Based on a surveyor's review of hematology calibration records and interview with the testing person, calibration of the hematology analyzer was not performed at the frequencies required by the laboratory's calibration protocol and by the manufacturer of the analyzer. FINDINGS: 1. The laboratory is using the Coulter AcT Diff analyzer. The laboratory's calibration policy and the manufacturer of the hematology analyzer require analyzer calibration every six months. 2. On June 29, 2018 at approximately 3: 30 PM the testing person confirmed that the documentation of the AcT Diff analyzer calibration available for review was for calibration performed on 7/16/16, 9/20/17 and 1/6/18. The hematology analyzer was therefore out of calibration from 1/17/2017 through 9/19/2017. 3. The records of calibration performed on 7/8/2017 indicated that calibration failed for multiple analytes. 4. Approximately 100 patient specimens were tested and reported for hematology during the above time period when analyzer was out of calibration. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor's review of Quality Control (QC) records and interview with the testing person, the laboratory failed to program the manufacturer expected ranges, as defined on the QC assay sheets, into the Beckman Coulter AcT Diff analyzer. FINDINGS: 1. On June 29, 2018 at approximately 3:30 PM the testing person confirmed the surveyor's review of QC records finding that the laboratory failed to -- 2 of 3 -- program the established QC ranges into the Beckman Coulter AcT Diff analyzer for hematology tests performed in calendar year 2017 and up to survey date. 2. Approximately 500 patients' specimens were tested and reported for hematology during this time period. -- 3 of 3 --