CLIA Laboratory Citation Details
05D0664149
Survey Type: Standard
Survey Event ID: QFT511
Deficiency Tags: D2122 D6010 D2016 D6000 D6019
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on Surveyors' review of laboratory's proficiency testing (PT) results from the American Association of Bioanalysts Medical Laboratory Evaluation (AAB-MLE), and interviews with the technical consultant (TC) and testing personnel (TP) on May 2, 2024, at approximately 11:00 a. m., the laboratory failed to attain at least 80% score in the proficiency testing program for the chemistry. The findings include: 1. The laboratory participated in the AAB-MLE PT testing program for the specialty of chemistry in the period of 2022 to 2024. However, it received an unsatisfactory score of 20% for third event of 2022 (Q3-2022), 60% score for first event of 2023 (Q1- 2023), and 40% score for first event of 2024 (Q1-2024) for Chloride analyte resulting Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- in an unsuccessful participation. Therefore, the accuracy of the patients' test results rendered by the laboratory during that time cannot be assured. 2. The TC and TP affirmed on May 2, 2024, at approximately 11:00 a.m. that the laboratory failed to achieve satisfactory performance for Chloride analyte for Q3-2022, Q1-2023, and Q1- 2024. 3. Based on the laboratory's testing declaration form signed by the laboratory director on May 1, 2024, the laboratory performs approximately 68,000 tests in chemistry including Chloride annually. D2122 HEMATOLOGY CFR(s): 493.851(b) Failure to attain an overall testing event score of at least 80 percent is unsatisfactory performance. This STANDARD is not met as evidenced by: Based on the review of the American Association of Bioanalysts - Medical Laboratory Evaluation (AAB-MLE) proficiency testing (PT) records, interviews with the technical consultant (TC) and testing personnel (TP), it was determined that the laboratory failed to attain an overall testing event score of at least 80 percent resulting to an unsatisfactory performance for the Nonchemistry first event in 2023 (Q1-2023) for the Platelet analyte. The findings included: 1. Based on the survey conducted on May 2, 2024, at approximately 11:00 a.m. and review of the proficiency testing results, it was determined that no
Get full access to the detailed deficiency summary for this facility
Survey Type: Special
Survey Event ID: 23G511
Deficiency Tags: D2016 D6000 D2096 D6016
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the specialty of Routine Chemistry constituting unsuccessful PT performance. (See D2096) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D), it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Chloride, as follows: 2022 Q3 2023 Q1 Chloride (CL) 20% 60% Q1 = First testing event Q3 = Third testing event b. Failure to achieve satisfactory performance for the same analyte or test in two of three consecutive PT resulted in an initial unsuccessful performance for the analyte, CL.. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: For the analyte CL, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in unsuccessful PT performance (see D2096) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D2016) -- 2 of 2 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Standard
Survey Event ID: V0SR11
Deficiency Tags: D2087 D6015 D2021 D2123
Summary Statement of Deficiencies D2021 BACTERIOLOGY CFR(s): 493.823(b) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on a review of the CMS Casper report 096 and the lack of documentation related to proficiency testing (PT) program and an interview with the laboratory personnel (LP) , it was determined that the laboratory failed to enroll in proficiency testing for Bacteriology for Cycle 2, 2021. The laboratory inspection occurred on 11 /10/21 between 11 a.m. and 1 p.m. Findings include: 1. The Casper 096 report for the 2019-2021 was reviewed, and there was a 0 score for Bacteriology for cycle 2, 2021. 2. The LP indicated the proficiency agency, College of American Pathology (CAP), was not notified of the planned discontinuation of Bacteriology testing. 3. At approximately 12:00 p.m. on 11/10/21, the LP affirmed that there was no proficiency report for Bacteriology for the timeframe indicated above. D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on the surveyor's review of the laboratory's records for evaluation of proficiency testing performance from the CMS 96 Report, laboratory proficiency reporting from CAP, and an interview with the LP on 11/10/2021 between 11:00 a.m. and 1:00 p.m., it was determined that there were two unacceptable (below 80 %) proficiency testing (PT) results for Chemistry in the 2010 and 2020 submission date ranges. Findings include: 1. On 11/10/2021, an inspection was conducted between 11: 00 a.m. and 1:00 p.m. 2. During a review of the laboratory documentation from CAP , it was noted at approximately 11:30 a.m. that there were two unacceptable PT results for general chemistry. The laboratory utilizes the Horiba ABX instrument for general chemistry testing. The LP recognized these atypical results. 3. The findings and acceptable ranges were as follows: Cycle 3 2019 Chemistry Analyte: Iron (2/5 unacceptable) Sample Actual Result Expected Result (range) 11 72 39-58 12 78 51-76 Cycle 2 2020 Chemistry Analyte: Testosterone (1/2 unacceptable) Sample Actual Result Expected Result (range) 7 1 668-1241 4. The LP affirmed the unacceptable results listed above. D2123 HEMATOLOGY CFR(s): 493.851(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on a review of the CMS Casper report 096 and the lack of documentation related to proficiency testing (PT) program and an interview with the laboratory personnel (LP) , it was determined that the laboratory failed to enroll in proficiency testing for Hematology for Cycle 3, 2020. The laboratory inspection occurred on 11/10 /21 between 11 a.m. and 1 p.m. Findings include: 1.The Casper 096 report for the 2019-2021 was reviewed, and there was a 0 score for Bacteriology for cycle 2, 2021. 2.The LP indicated the proficiency agency, College of American Pathology (CAP) did not receive the proficiency data. 3. At approximately 12:15 0 p.m. on 11/10/21, the LP affirmed that there was no proficiency report for Hematology for the timeframe indicated above. D6015 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4) Ensure that the laboratory is enrolled in an HHS approved -- 2 of 3 -- proficiency testing program for the testing performed. This STANDARD is not met as evidenced by: Based on a review of the CMS Casper report 096 and the lack of documentation related to proficiency testing (PT) program and an interview with the laboratory personnel (LP) , it was determined that the laboratory failed to enroll in proficiency testing for Hematology for Cycle 3, 2020 and Bacteriology for Cycle 2, 2021. The laboratory inspection occurred on 11/10/21 between 11 a.m. and 1 p.m. Findings include: 1. The laboratory director did not ensure that the laboratory was enrolled in an HHS approved proficiency program for each testing cycle. 2. See D 2021 and D 2123 for details. -- 3 of 3 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Special
Survey Event ID: Z9YE11
Deficiency Tags: D2016 D6000 D2130 D6016
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the specialty of Hematology constituting unsuccessful PT performance. (See D2130) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Platelet count, resulting in an "initial" (first) unsuccessful performances. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for the analyte, Platelet count, as follows: 2020 Q2 2020 Q3 Platelet count 60% 0% Q2 = Second Testing Event Q3 = Third Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an initial unsuccessful performance for the analyte, Platelet count. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6016) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the analyte, Platelet count, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in unsuccessful PT performance. (See D2016 and D2130) -- 2 of 2 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Special
Survey Event ID: JO2T11
Deficiency Tags: D2130 D6016 D2016 D6000
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the specialty of Hematology constituting unsuccessful PT performance. (See D2130) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Hematocrit (HCT), resulting in an "initial" (first) unsuccessful performances. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for the analyte, HCT, as follows: 2019 Q1 2019 Q3 HCT 20% 60% Q1 = First Testing Event Q3 = Third Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an initial unsuccessful performance for the analyte, HCT. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6016) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the analyte, HCT, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in an unsuccessful PT performance. (See D2016 and D2130) -- 2 of 2 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Standard
Survey Event ID: QECW11
Deficiency Tags: D5215 D2121 D6019
Summary Statement of Deficiencies D2121 HEMATOLOGY CFR(s): 493.851(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on review of the laboratory's proficiency testing (PT) records, random patient sampling and interview with testing personnel, it was determined that the laboratory failed to attain a score of at least 80 percent of acceptable responses for the Hematocrit (HCT)analyte. The findings included: a. American Association of Bioanalysts (AAB) proficiency program gave an unsatisfactory score 20 % for HCT, first quarter 2019. b. Based on the laboratory's annual testing declaration submitted for 2018-2019, the laboratory analyzed and reported 52,000 Complete Blood Count (CBC) which included the HCT analyte. c. The testing personnel confirmed (11/20 /2019, 14:30) that the laboratory received the above proficiency score of 20% for HCT. D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on review of second quarter (Q2-2019) of the American Association of Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Bioanalysts (AAB)proficiency testing reports, laboratory proficiency testing records and interview with the testing personnel, the laboratory failed to have a mechanism to review proficiency testing results that have an artificial score of 100% even though the laboratory's reported results were outside the grading range. The findings included: a. The laboratory received an artificial score of 100% for Folate for the (Q2- 2019). The AAB proficiency test footnote reports revealed that for results with prefix codes indicated the following statement: # = "This method was not graded due to an insufficient number of peer respondents. No appropriate default grouping was available. The listed range should provide a reasonable guide to your performance. However, exercise caution in evaluating your results." The following proficiency sample was analyzed and reported by the laboratory: Folate Specimen: Value. Mean: Grading Score: Reported Range: Spec: 2 # 4.6 2.72 1.8-3.6 100% Note: True score should have 50%. b. The testing personnel confirmed (11/20/2019, 14:30) that the laboratory received the above artificial 100% passing score even though the reported results were outside the grading range for Folate analyte. c. Based on the laboratory's annual testing declaration submitted for 2018-2019, the laboratory analyzed and reported 1,500 for Folate analyte. D6019 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iv) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iv) Ensure that an approved
Get full access to the detailed deficiency summary for this facility