Sagis

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 45D2044865
Address 1033 La Posada Dr Ste 306, Austin, TX, 78752
City Austin
State TX
Zip Code78752
Phone(877) 697-2447

Citation History (2 surveys)

Survey - April 3, 2024

Survey Type: Standard

Survey Event ID: 2HDG11

Deficiency Tags: D0000 D5601 D5791 D0000 D5601 D5791

Summary:

Summary Statement of Deficiencies D0000 The laboratory was surveyed and found to be in compliance with the Conditions of the CLIA regulations found at 42 CFR 493.1 through 493.1780, and recertification is recommended. D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of test reports, quality control (QC) records, query, and interview, the laboratory failed to document the positive and negative reactivity to ensure predictable staining characteristics for the immunohistochemical (IHC) stains used in its histopathology and dermatopathology interpretations for one of six test reports with IHCs and/or special stains reviewed from January 2023 - March 2024. Finding follow. A. Review of six test reports from 01/12/2023 - 03/07/2024 with IHCs or special stains showed one report, Accession #SD23-003325 reported 1/12/2023, was missing the comment documenting the performance of the quality control on the test report (which represented the documentation of quality control for the IHCs and special stains). The IHC panel performed for Accession #SD23-003325 included the following stains: 1. MSH2 (Mismatch Repair Protein) (79H11) 2. MLH1 (Mismatch Repair Protein) (ES05) 3. MSH6 (Mismatch Repair Protein) (EP49) 4. PMS2 (MRQ- 28) B. Review of a query for the IHC panel (above) identified 33 cases received between 01/30/2022 - 04/13/2023 were impacted. C. Interview on March 3, 2024 at 1100 hours the Laboratory Director confirmed the findings at (A), and acknowledged Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- he was just informed of the problem that one of the panels did not populate the control comment on the test report. Interview on March 3, 2024 at 1315 hours the Laboratory Director acknowledged the problem was discovered by an LIS employee on 04/11 /2023 and corrected on 04/28/2023 and confirmed findings at (B). D. Review of the CMS-116 showed the laboratory performed approximately 129,000 (total blocks, special stains and IHCs) tests per year. KEY: LIS = Laboratory Information System D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on review of test reports, quality control (QC) records, query, laboratory's policy and procedure, and interview, the laboratory failed to follow its written policies and procedures for an ongoing mechanism to monitor, assess, and correct problems identified in the analytic systems for 11 of 11 months reviewed (refer to D5601). Finding follow. A. Review of the laboratory's policy and procedure titled Quality Assurance (QA), adopted 06/04/2018, under Ongoing Assessment stated, "Each of the laboratory's quality systems will undergo assessment on a regular basis to maintain and improve laboratory performance and services. This assessment includes the following practices: ...The Laboratory Director or an appropriate, designated staff member will conduct meetings with all relevant staff every 6 months to communicate the results of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 10, 2020

Survey Type: Standard

Survey Event ID: 97FX11

Deficiency Tags: D5473 D5473

Summary:

Summary Statement of Deficiencies D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the laboratory's policies and procedures, quality control records, patient test results and interview, the laboratory failed to document the negative and positive intended reactivity of quality control slides for Hematoxylin & Eosin (H&E) each day of patient testing. Findings follow. 1. Review of the laboratory's procedure Examination of histologic Slides and Reporting of Results, version 1, effective date 3 /31/2016, on page 2 under Quality Control stated, "Documentation should be kept daily on quality of routine slides to be graded as excellent, acceptable, or unacceptable with type of staining protocol reported on the QA log. If at any time, a grade of "unacceptable" is assigned, the type of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access