CLIA Laboratory Citation Details
32D0536156
Survey Type: Standard
Survey Event ID: 1ECK11
Deficiency Tags: D0000 D5413 D5421 D5423 D5781 D0000 D5413 D5421 D5423 D5781
Summary Statement of Deficiencies D0000 Based upon the onsite validation survey conducted from 02/13/2023 to 02/15/2023, this facility was found to be IN compliance with the CLIA regulations found at 42 CFR for the specialties/subspecialties in which it was surveyed with standard level deficiencies cited. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on direct observation, review of manufacturer's instructions, laboratory records, and confirmed in staff interview, the laboratory failed to ensure laboratory room temperatures were defined according to manufacturer's specifications for 6 of 6 months (09/2021-11/2021 and 09/2022-11/2022). Findings included: 1. During a tour of the laboratory room on 02/13/2023 at 1:40 pm, one Tosoh G8 Glycohemoglobin Analyzer (Serial number 15869205) was observed. 2. Review of the manufacturer's instructions titled "TSKgel G8 Variant Hsi" (Revision 2.0; 08/19/2021) stated "7. Specimens ... Specimens may be stored up to twenty four hours at room temperature 10-25C" (50-77F)." 3. Review of the laboratory forms, titled "Daily Temperature /Hydrometer Checks", dated from 09/2021 through 11/2021 and 09/2022 through 11 /2022, stated "Room Temperature (large lab) 68-86F" (20-30C)." The laboratory's room temperature upper limit of 86F exceeded the manufacturer's specified upper limit of 77F. 4. During an interview on 02/14/2023 at 2:30 pm in the conference room, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- after review of the above records, the Laboratory Director (as listed on Centers for Medicare & Medicaid Services (CMS)-209 FORM; signed by the Laboratory Director on 02/01/2023) confirmed the findings. Word key: C = degrees Celsius F = degrees Fahrenheit D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of laboratory policies, laboratory records, and confirmed in staff interview, the laboratory failed to have documentation of performance of verification studies to include reportable range and normal reference range for 1 of 1 assay performed on the Tosoh G8 Glycohemoglobin Analyzer (Serial number 15869205) prior to patient testing. Findings included: 1. Review of the laboratory policy titled "Quality Assessment Plan" (reviewed by the Laboratory Director on 09/13/2022) stated: a. "New Testing ... Reportable Range ... The kit does not need to hit the max of the analyte. It does however need to test the reportable range to an extent to confirm linearity." b. "New Testing ... Reference range: The reference range given in the package insert will be used as the patient reference range." 2. Review of the laboratory policy titled "Tosoh G8 Glycohemoglobin Analyzer" (reviewed by the Laboratory Director on 09/22/2022) stated "REPORTABLE RANGE/LINEARITY: 3.1 - 19.0%". Review of the laboratory record titled "sAS1C Accuracy, Reportable Range, and Linearity" (signed by the Laboratory Director on 11/07/2019) revealed the following results: Lyphocheck Hemoglobin A1C Linearity Set; Lot 34710 Expiration date 06/30/2021 ID 0008 - Level 01 result: "---% SA1C TOO LOW" (Expected Value 2.7% - 3.8%) ID 0009 - Level 01 result: "---% SA1C TOO LOW" Level 02 mean result: 4.70% (Expected Value 4.1% - 5.1%) Level 03 mean result: 5.95% (Expected Value 5.5% - 6.5%) Level 04 mean result: 9.90% (Expected Value 8.4% - 10%) Level 05 mean result: 14.2% (Expected Value 12% - 15%) ID 0008 - Level 06 result: "---%" (Expected Value 16% - 22%) ID 0009 - Level 06 result: "---%" The laboratory verified a reportable range of 4.7% to 14.2%. The laboratory failed to verify the reportable range of 3.1% - 19% stated in the laboratory policy. 3. During an interview on 02/14/2023 at 1:05 pm in the conference room, the surveyor requested documentation of the studies to verify the laboratory's normal reference range. No documentation was provided. The Laboratory Director, after review of the above records, confirmed the laboratory failed to perform verification studies to include reportable range and normal reference range for the Tosoh G8 Glycohemoglobin Analyzer. Word key: A1C = glycated hemoglobin D5423 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(2) Each laboratory that modifies an FDA-cleared or approved test system, or introduces a test system not subject to FDA clearance or approval (including methods developed -- 2 of 5 -- in-house and standardized methods such as text book procedures), or uses a test system in which performance specifications are not provided by the manufacturer must, before reporting patient test results, establish for each test system the performance specifications for the following performance characteristics, as applicable: (2)(i) Accuracy. (2)(ii) Precision. (2)(iii) Analytical sensitivity. (2)(iv) Analytical specificity to include interfering substances. (2)(v) Reportable range of test results for the test system. (2)(vi) Reference intervals (normal values). (2)(vii) Any other performance characteristic required for test performance. This STANDARD is not met as evidenced by: Based on review of the user manual for the Horiba ABX Micros 60 (hematology instrument), review of laboratory procedure, sample stability study for Complete Blood Counts (CBC), laboratory sample collection logs, patient result records, and interview with the laboratory director, the laboratory failed to establish performance specification to include accuracy, precision, analytical sensitivity, and specificity for the modified sample stability and handling of the hematology samples collected in an EDTA Becton Dickenson vacutainer blood collection tube prior to resulting 1 of 425 patients from October 2022 to February 2023. Findings included: 1. Review of the Horiba ABX Micros 50 user manual, under section labeled "Sample Stability" stated; "Fresh Whole Blood specimens are recommended! The ICSH (International Committee for Standardization in Hematology) defines a Fresh blood specimen as 'one processed within 4 hours after collection'. Well mixed Whole Blood specimens, collected in EDTA anti-coagulant and run within eight hours after collection, provide the most accurate results for all parameters. The White cell size distribution may shift when specimens are assayed between 5 and 20 minutes after collection and more than 8 hours after collection." 2. Review of the laboratory Procedure titled, "ABX Micros 60 procedure" stated; "SPECIMEN 2 ml (min) EDTA anticoagulated blood sample not more than 24 hours old." The "not more than 24 hours old" was crossed out and a handwritten note stated, "Extended to 4 days per QA study and Medical Director Review 12/29/17". The facility failed to have the laboratory director sign the amended procedure. 3. Review of the sample stability study for the CBC test revealed that the study consisted of 10 patient samples, originally collected on 12/18/2017 and re-tested again on 12/21/2017. The laboratory failed to include defined criteria or limits of acceptability for their specimen stability comparison study. The facility failed to establish performance specification studies to include to include accuracy, precision, analytical sensitivity, and specificity for the modified sample stability and handling of the hematology samples collected in an EDTA Becton Dickenson vacutainer blood collection tube. The laboratory failed to perform a 4-day (96 hours) sample stability and handling study, as stated on the handwritten note in their hematology procedure. 4. Review of the patient collection log and patient's CBC test results from October 2022 to Feb 13, 2023, revealed patient (ID# 209039) was collected on Friday, November 18, 2022 at 9:31 am and analyzed and reported on Monday, November 21, 2022 at 5:17 pm, 79 hours and 46 mins from the time of collection. 5. During an interview on 02/15/2023 at 1:15 pm, the laboratory director stated, "I was under the impression that the stability was good", confirming the findings above. D5781
Get full access to the detailed deficiency summary for this facility