Schweiger Dermatology Group

CLIA Laboratory Citation Details

2
Total Citations
10
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 39D2158019
Address 822 Pine St, Lower Level, Philadelphia, PA, 19107
City Philadelphia
State PA
Zip Code19107
Phone(267) 519-0154

Citation History (2 surveys)

Survey - July 21, 2026

Survey Type: Standard

Survey Event ID: NUTQ11

Deficiency Tags: D0000 D5429 D5781 D6168 D6171

Summary:

Summary Statement of Deficiencies D0000 A recertification certification survey was conducted by the Pennsylvania State Agency for Schweiger Dermatology Group on 07/21/2026. The laboratory was found out of compliance with the following condition: 493.1487 Condition: Laboratories performing high complexity testing; testing personnel. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) (a)(1) Maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on observation of the laboratory, lack of documentation, and interview with the Lead Lab Tech (LLT), the laboratory failed to assess the maintenance and function checks as defined by the manufacturer for 2 of 2 thermometers and 1 of 1 hygrometer /thermometer used to ensure acceptable storage and operating temperatures were met in the laboratory when histopathology testing was performed from 01/27/2025 to 07/21 /2026. Findings Include: 1. On the day of the survey, 07/21/2026 at 10:45 am, observation of the laboratory revealed 1 of 1 room temperature and humidity hygrometer/thermometer with no expiration date, serial number or identifying label on the instrument. 2. Further observation revealed 2 of 2 Traceable thermometers (S/N: 240260321, 240260322) due 26 Mar 2026. 3. The laboratory could not provide maintenance/function check records for the 2 of 2 thermometers and 1 of 1 hygrometer /thermometer used to record temperature and humidity in the laboratory when histopathology testing was performed from 01/27/2025 to 07/21/2026. 3. The LLT confirmed the above findings on 07/21/2026 at 11:00 am. D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 14, 2022

Survey Type: Standard

Survey Event ID: C9JI11

Deficiency Tags: D5217 D6094 D6094 D5601 D5601

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on the review of the laboratory's procedure manual, peer review records, and interview with the lead histotechnologist (HT), the laboratory failed to ensure that the verification of accuracy for microscopic examinations for histopathology were performed at least twice annually, as required for tests not included in subpart I in 2021. Findings Include: 1. On the day of the survey, 12/14/2022 at 10:55 am, the laboratory could not provide documentation that the verification of accuracy for histopathology slide examinations stained using immunohistochemicals, special stains, and hematoxylin and eosin (H&E) were performed at least twice annually in 2021. 2. The laboratory performed 17,040 histopathology examinations in 2021 (annual volume listed on form CMS-116). 3. The HT confirmed the findings above on 12/14/2022 around 12:00 pm. D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on the review of the laboratory's quality control (QC) staining records and an interview with the lead histotechnologist (HT), the laboratory failed to check for negative staining reactivity each time of use for 16 of 16 immunohistochemical (IHC) stains used for histopathology examinations from 01/05/2021 to the date of the survey. Findings include: 1. On the day of the survey, 12/14/2022 at 09:45 am, review of the laboratory's IHC quality control log revealed that a control for negative reactivity was not performed for each use of the following 16 of 16 IHC stains used for histopathology examinations from 01/05/2021 to 12/14/2022: -Melan A -SOX10 - CD68 -CD7 -CD8 -CD30 -KI67 -CK20 -AEI/AE3 -S100 -Factor XIIIA -CD20 -CD3 - CD34 -CD4 -CD5 2. In 2021, 1,757 IHC stained slides were used for histopathology examinations. 3. The HT confirmed the findings above on 12/14/2022 at 12:00 pm. D6094 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on the lack of quality assurance (QA) documentation and an interview with the lead histotechnologist (HT), the laboratory director (LD) failed to ensure a QA program was established and maintained to ensure the quality of services provided by the laboratory from 01/05/2021 to the date of the survey. Findings include: 1. On the date of the survey, 12/14/2022 at 11:14 am, the laboratory could not provide documentation for the periodic QA evaluation performed to assess the laboratory's pre- analytical, analytical, and post-analytical processes from 01/05/2021 to 12/14/2022. 2. The laboratory performed 17,040 histopathology examinations in 2021 (the annual volume listed on the CMS-116 form). 3. The HT confirmed the findings above on 12 /14/2022 around 12:00 pm. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access