Schweiger Dermatology, Pc - Princeton

CLIA Laboratory Citation Details

2
Total Citations
4
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 31D0937983
Address 800 Bunn Drive Suite 201, Princeton, NJ, 085401968
City Princeton
State NJ
Zip Code085401968
Phone(609) 924-1033

Citation History (2 surveys)

Survey - February 26, 2024

Survey Type: Standard

Survey Event ID: XOOC11

Deficiency Tags: D5413 D5435

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on surveyor review of the staining dyes and "Room Temperature and Humidity Log" (LOG) and interview with the Histotechnicians (HT), the laboratory failed to provide an accurate room temperature acceptable range per the staining dyes labels on the LOG from 6/13/23 to the date of the survey. The findings include: 1. The surveyor observed the strictest requirement for the room temperature, 68-86F, based on the staining dyes labels, but the acceptable range was 40-95F on the LOG. 2. The HT's confirmed on 2/26/24 at 2:30 pm that the acceptable range for room temperature on the LOG was not accurate. D5435 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(2) For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must: (i) Define a function check protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. (ii) Perform and document the function checks, including background or Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- baseline checks, specified in paragraph (b)(2)(i) of this section. Function checks must be within the laboratory's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: Based on surveyor review of the Procedure Manual (PM) and Antonki thermohygromoter and interview with the Histotechnicians (HT) at the time of the survey, the laboratory failed to provide a written procedure for and documentation of calibration for all thermometers used in the laboratory from 6/13/23 to the date of the survey. The findings include: 1. The laboratory could not provide a written procedure for the calibration or replacement of all thermometers used, including the Antonki thermohygrometer, in the laboratory. 2. The laboratory could not provide documentation of current calibration for the Antonki thermohygrometer, used for room temperature and humidity, which expired on 12/14/2023. 3. The HT's confirmed on 2/26/24 at 2:45 pm that they could not provide a written procedure for performing calibration or replacement of the thermometers nor provide documention of current calibration for the Antonki thermohygrometer. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 31, 2019

Survey Type: Standard

Survey Event ID: D3CW11

Deficiency Tags: D5413 D6091

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on surveyor review of the Temperature Logs (TL) and interview with the Testing Personnel (TP), the laboratory failed to define a temperature range for the Room Temperature (RT) and Humidity where Mohs tests were performed from 7/18 /17 to the date of survey. The TP confirmed on 7/31/19 at 1:30 pm that the laboratory did not define RT and Humidity. D6091 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(iii) The laboratory director must ensure all proficiency testing reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access