Seark Children's Clinic

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 04D2275735
Address 702 Hl Ross Dr, Monticello, AR, 71655
City Monticello
State AR
Zip Code71655
Phone870 276-6966
Lab DirectorJULIA BARNES

Citation History (2 surveys)

Survey - October 22, 2025

Survey Type: Standard

Survey Event ID: UPFM11

Deficiency Tags: D5429 D6032 D5415 D5807

Summary:

Summary Statement of Deficiencies D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) (c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (c)(1) Identity and when significant, titer, strength or concentration. (c)(2) Storage requirements. (c)(3) Preparation and expiration dates. (c)(4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Through review of package inserts, observation, and interview it was determined that the laboratory did not change expiration dates on control materials after opening as required by manufacturer. Finding follow: A) Review of the package insert for XN-L Check Hematology controls revealed that the product expires in 15 days after vial is opened and put into use and the expiration dates should be changed as required after opening. B) During a tour of the laboratory on 10/22/25 at 3:35 p.m.the surveyor observed a plastic container with three vials of XN-L Check hematology controls , lot #' 523514 expiration date 2025-12-02. The vials did not have new expiration dates or dates put into use indicated on the testing materials or the container and were identified as the controls currently in use. C) In an interview on 10/22/25 at 03:35 p.. m. laboratory staff member (number 1 on form CMS 209) confirmed that no amended expiration date or date when put into use were written on the vials or container. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) (a)(1) Maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based upon review of Sysmex XN-300 Hematology Analyzer Checklist, lack of documentation and interviews with laboratory staff, the laboratory failed to perform required maintenance on the Sysmex XN-300 Hematology Analyzer in 2025 Survey findings include: A) The Sysmex XN-300 Maintenance Checklist includes a required weekly "Clean SRV Tray" and monthly maintenance "monthly clean RBC and WBC Transducer "and "Clean Waste Chamber". B) Review of the Sysmex XN-300 maintenance log for 2025 revealed weekly maintenance was not documented for any weeks in July 2025, August 2025, and September 2025 and monthly maintenance was not documented for any month in 2025. C) In an interview, at 03:30 p.m. on 10/22/25, laboratory staff member #1 (as listed on the form CMS-209) confirmed that weekly and monthly required maintenance for the Sysmex XN-300 was not documented in 2025. D5807 TEST REPORT CFR(s): 493.1291(d) (d) Pertinent "reference intervals" or "normal" values, as determined by the laboratory performing the tests, must be available to the authorized person who ordered the tests and, if applicable, the individual responsible for using the test results. This STANDARD is not met as evidenced by: Based upon review of patient reports and interview with laboratory staff the laboratory did not make a reference range for complete blood cell (CBC) assays available to the individual responsible for using the test results. Findings follow: A) Review of the final report for a CBC assay on a patient identified as number 2579 revealed that, under the heading "Reference Range", the report was blank and no reference range was given. B) In an interview on 10/22/25 at 03:40 p.m., laboratory staff member (1 on form CMS 209) confirmed that the reference range was not included on the report identified above, and that investigation of other CBC reports showed that the reference range was not included. D6032 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(14) (e)(14) Specify, in writing, the responsibilities and duties of each consultant and each person, engaged in the performance of the preanalytic, analytic, and postanalytic phases of testing, that identifies which examinations and procedures each individual is authorized to perform, whether supervision is required for specimen processing, test performance or results reporting, and whether consultant or director review is required prior to reporting patient test results. This STANDARD is not met as evidenced by: . Based upon review of personnel files for testing personnel listed on the form CMS- 209, lack of documentation, and interviews with laboratory staff, the laboratory director failed to authorize five of five testing personnel to perform testing without direct supervision. Survey findings include: A) Review of personnel files for five testing personnel listed on form CMS-209 (Personnel #'s 2, 3, 4, 5, 6 ) revealed written authorization from the laboratory director to perform moderately complex testing without direct supervision was not present. B) In an interview, at 12:50 p.m. on 10/22/25 laboratory staff member #1 (as listed on the form CMS-209) confirmed the -- 2 of 3 -- lack of written authorizations to test for employees (#'s 2 , 3, 4, 5, 6) on form CMS 209). -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 31, 2024

Survey Type: Standard

Survey Event ID: OVDB11

Deficiency Tags: D5417 D2000 D6015

Summary:

Summary Statement of Deficiencies D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: Through a review of the laboratory test menu, a review of CASPER 155 reports for 2023, lack of documentation, and interviews with laboratory personnel, it was observed the laboratory failed to enroll in proficiency testing for CBC (complete blood count). Survey findings include: A. A review of the laboratory's test menu revealed the laboratory performed CBCs on the Sysmex XN-330. B. No proficiency test results for the facility were shown for 2023 in the CASPER 155 reports. C. In an interview, at 8:58 a.m. on 1/3/24, laboratory personell #1 (as listed on the form CMS- 209) confirmed the laboratory was not enrolled in proficiency testing for CBC. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Through observation and interview with laboratory staff it was determined that the laboratory had supplies available for use after their expiration date. Findings follow: A) During a tour of the laboratory on 01/31/24 at 11:20 a.m. one (of one) BRT Liquid Assayed Chemistry + Liquid Control (Lot: 2207030, ref: 100-9010, 2Lx 6Vx1.0mL, expiration date 12/31/2023) was observed in the laboratory. B) In an interview on 01 /31/24 at 11:20 a.m. laboratory staff member (listed as #1 on the CMS 209 form) confirmed that the item, identified above, had exceeded it's expiration date and was available for use. D6015 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4) Ensure that the laboratory is enrolled in an HHS approved proficiency testing program for the testing performed. This STANDARD is not met as evidenced by: Based on review of the laboratory test menu, a lack of CASPER 155 reports for 2023, lack of documentation, and interviews with laboratory personnel, it was determined the laboratory director failed to ensure the laboratory was enrolled in proficiency testing for the CBCs as cited at D2000. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary